A tin filter?s dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest

被引:6
|
作者
Hasegawa, Akira [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Morioka, Yusuke [2 ,4 ]
Kawashima, Hiroki [3 ]
机构
[1] Niigata Univ Hlth & Welf, Fac Med Technol, Dept Radiol Technol, 1398 Shimami cho,Kita ku, Niigata, Niigata 9503198, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Toyama Prefectural Cent Hosp, Dept Radiol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 99卷
关键词
Chest computed tomography; Tin filter; Radiation dose; Detectability index; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; SPECTRAL FILTRATION; 100; KVP; CT; PERFORMANCE;
D O I
10.1016/j.ejmp.2022.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reevaluate a tin filter's (TF) dose reduction effect in computed tomography (CT) using a combination of an anthropomorphic chest phantom and a rod-shaped phantom. Methods and materials: A third-generation dual-source CT system equipped with a built-in TF was employed. A chest phantom was scanned under low-dose conditions of 0.2 to 1.0 mGy with the TF at 100 kV (TF100kV) and without it at 100 kV and 120 kV (NF100kV and NF120kV). To eliminate effects other than that of the TF, only filtered back projection (FBP) was used for image reconstruction. On the images of the rod phantom placed inside the lung field, the CT number and the spatial resolution using the modulation transfer function (MTF) were measured. Using these indices plus the noise power spectrum (NPS) that was also measured, the detectability index based on the non-prewhitening model observer (d'NPW) was calculated.Results: The CT numbers and MTFs were almost identical across the three conditions. The area under the NPS curve was decreased by 13-17% with the TF compared with non-TF conditions. NPS increases at low frequencies of < 0.06 mm-1 observed in NF120kV and NF100kV were eliminated by TF100kV. The potential dose reduction by the TF, estimated using the d'NPW values, turned out to be 22 to 25%.Conclusion: Based on the analysis of the FBP images of a chest phantom, the dose reduction attributable only to the TF was estimated at 22-25%, notably lower than those reported in previous studies.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [21] Technical Note: Radiation dose reduction from computed tomography localizer radiographs using a tin spectral shaping filter
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    MEDICAL PHYSICS, 2019, 46 (02) : 544 - 549
  • [22] Texture transformer super-resolution for low-dose computed tomography
    Zhou, Shiwei
    Yu, Lifeng
    Jin, Mingwu
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06):
  • [23] Low-Dose Computed Tomographic Urography Using Adaptive Iterative Dose Reduction 3-Dimensional: Comparison With Routine-Dose Computed Tomography With Filtered Back Projection
    Juri, Hiroshi
    Matsuki, Mitsuru
    Inada, Yuki
    Tsuboyama, Takahiro
    Kumano, Seishi
    Azuma, Haruhito
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 426 - 431
  • [24] ULTRA-LOW-DOSE COMPUTED TOMOGRAPHY IN UROLITHIASIS-EFFECT OF AN ADDITIONAL TIN FILTER ON IMAGE QUALITY AND RADIATION DOSE
    Haubold, Johannes
    Zensen, Sebastian
    Erfanian, Youssef
    Guberina, Nika
    Opitz, Marcel
    Sawicki, Lino Morris
    Forsting, Michael
    Umutlu, Lale
    Theysohn, Jens M.
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 146 - 153
  • [25] Lung Cancer Screening Using Low-Dose Computed Tomography
    Hirsch, Brandon
    RADIOLOGIC TECHNOLOGY, 2022, 93 (03) : 303CT - 321CT
  • [26] Radiation Dose Reduction in Cervical Spine Computed Tomography in Cervical Spine Trauma: Comparison of Low-dose with Standard-dose Multidetector Computed Tomography
    Man, K. Y.
    Mo, K. M.
    Sung, H. T.
    Cho, K. Y.
    Tam, C. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (03): : 180 - 187
  • [27] Low-Dose Computed Tomography in the Evaluation of Urolithiasis
    Bhatt, Kavita
    Monga, Manoj
    Remer, Erick M.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (05) : 504 - 511
  • [28] Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations
    Schmidt, Bernhard T.
    Hupfer, Martin
    Saltybaeva, Natalia
    Kolditz, Daniel
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (02) : 81 - 86
  • [29] Low-Dose Carotid Computed Tomography Angiography Using Pure Iterative Reconstruction
    Moloney, Fiachra
    Murphy, Kevin P.
    Twomey, Maria
    Crush, Lee
    Canniffe, Emma M.
    McLaughlin, Patrick D.
    Moore, Niamh
    O'Keeffe, Michael
    O'Neill, Siobhan
    Manning, Brian M.
    Wyse, Gerald
    Fanning, Noel
    O'Connor, Owen J.
    Maher, Michael M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) : 833 - 839
  • [30] Evaluation of optimal parameters for using low-dose computed tomography to diagnose urolithiasis
    Chen, Hui-Hsien
    Yu, Cheng-Ching
    Hsu, Fang-Yuh
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 242 - 246