A tin filter?s dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest

被引:6
|
作者
Hasegawa, Akira [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Morioka, Yusuke [2 ,4 ]
Kawashima, Hiroki [3 ]
机构
[1] Niigata Univ Hlth & Welf, Fac Med Technol, Dept Radiol Technol, 1398 Shimami cho,Kita ku, Niigata, Niigata 9503198, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Toyama Prefectural Cent Hosp, Dept Radiol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 99卷
关键词
Chest computed tomography; Tin filter; Radiation dose; Detectability index; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; SPECTRAL FILTRATION; 100; KVP; CT; PERFORMANCE;
D O I
10.1016/j.ejmp.2022.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reevaluate a tin filter's (TF) dose reduction effect in computed tomography (CT) using a combination of an anthropomorphic chest phantom and a rod-shaped phantom. Methods and materials: A third-generation dual-source CT system equipped with a built-in TF was employed. A chest phantom was scanned under low-dose conditions of 0.2 to 1.0 mGy with the TF at 100 kV (TF100kV) and without it at 100 kV and 120 kV (NF100kV and NF120kV). To eliminate effects other than that of the TF, only filtered back projection (FBP) was used for image reconstruction. On the images of the rod phantom placed inside the lung field, the CT number and the spatial resolution using the modulation transfer function (MTF) were measured. Using these indices plus the noise power spectrum (NPS) that was also measured, the detectability index based on the non-prewhitening model observer (d'NPW) was calculated.Results: The CT numbers and MTFs were almost identical across the three conditions. The area under the NPS curve was decreased by 13-17% with the TF compared with non-TF conditions. NPS increases at low frequencies of < 0.06 mm-1 observed in NF120kV and NF100kV were eliminated by TF100kV. The potential dose reduction by the TF, estimated using the d'NPW values, turned out to be 22 to 25%.Conclusion: Based on the analysis of the FBP images of a chest phantom, the dose reduction attributable only to the TF was estimated at 22-25%, notably lower than those reported in previous studies.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [1] Usefulness of Ag Additional Filter on Image Quality and Radiation Dose for Low-Dose Chest Computed Tomography
    Kawamoto, Keishin
    Sato, Hideyuki
    Kogure, Yosuke
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 236 - 243
  • [2] A multi-institutional assessment of low-dose protocols in chest computed tomography: Dose and image quality
    Tonkopi, Elena
    Tetteh, Mercy Afadzi
    Gunn, Catherine
    Ashraf, Haseem
    Rusten, Sigrid Lia
    Safi, Perkhah
    Tinsoe, Nora Suu
    Colford, Kylie
    Ouellet, Olivia
    Naimi, Salma
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2024, 13 (01)
  • [3] Low-Dose Computed Tomography Colonography Technique
    Chang, Kevin J.
    Yee, Judy
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (05) : 709 - +
  • [4] A phantom study investigating the relationship between ground-glass opacity visibility and physical detectability index in low-dose chest computed tomography
    Ichikawa, Katsuhiro
    Kobayashi, Takeshi
    Sagawa, Motoyasu
    Katagiri, Ayako
    Uno, Yukiko
    Nishioka, Ryo
    Matsuyama, Jun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 202 - 215
  • [5] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [6] Detectability of pancreatic lesions by low-dose unenhanced computed tomography using iterative reconstruction
    Sugawara, Haruto
    Yoshikawa, Takeharu
    Kunimatsu, Akira
    Akai, Hiroyuki
    Yasaka, Koichiro
    Abe, Osamu
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 141
  • [7] A Challenge for Emphysema Quantification Using a Deep Learning Algorithm With Low-dose Chest Computed Tomography
    Choi, Hyewon
    Kim, Hyungjin
    Jin, Kwang Nam
    Jeong, Yeon Joo
    Chae, Kum Ju
    Lee, Kyung Hee
    Yong, Hwan Seok
    Gil, Bomi
    Lee, Hye-Jeong
    Lee, Ki Yeol
    Jeon, Kyung Nyeo
    Yi, Jaeyoun
    Seo, Sola
    Ahn, Chulkyun
    Lee, Joonhyung
    Oh, Kyuhyup
    Goo, Jin Mo
    JOURNAL OF THORACIC IMAGING, 2022, 37 (04) : 253 - 261
  • [8] Low-dose chest computed tomography screening of subjects exposed to asbestos
    Kato, Katsuya
    Gemba, Kenichi
    Ashizawa, Kazuto
    Arakawa, Hiroaki
    Honda, Satoshi
    Noguchi, Naomi
    Honda, Sumihisa
    Fujimoto, Nobukazu
    Kishimoto, Takumi
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 124 - 128
  • [9] Automated aortic calcium scoring on low-dose chest computed tomography
    Isgum, Ivana
    Rutten, Annemarieke
    Prokop, Mathias
    Staring, Marius
    Klein, Stefan
    Pluim, Josien P. W.
    Viergever, Max A.
    van Ginneken, Bram
    MEDICAL PHYSICS, 2010, 37 (02) : 714 - 723
  • [10] Validation for measurements of skeletal muscle areas using low-dose chest computed tomography
    Lim, Woo Hyeon
    Park, Chang Min
    SCIENTIFIC REPORTS, 2022, 12 (01)