Resilient Wide-Area Damping Control for Inter-Area Oscillations to Tolerate Deception Attacks

被引:29
|
作者
Yao, Wei [1 ]
Nan, Jiajun [1 ,2 ]
Zhao, Yifan [1 ]
Fang, Jiakun [1 ]
Ai, Xiaomeng [1 ]
Zuo, Wenping [1 ]
Wen, Jinyu [1 ]
Cheng, Shijie [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect Engn & Elect, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] State Grid Corp China State Grid, Natl Power Dispatching & Control Ctr, Beijing 100031, Peoples R China
基金
中国国家自然科学基金;
关键词
Damping; Oscillators; Cyberattack; Predictive control; Power system stability; Encryption; Phasor measurement units; Wide-area damping control; secure networked predictive control; inter-area oscillation; deception attacks; AC; DC hybrid power system; NETWORKED PREDICTIVE CONTROL; POWER-SYSTEMS; VSC-HVDC;
D O I
10.1109/TSG.2021.3068390
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Deception attacks that threaten communication networks will result in serious consequences ranging from the deterioration of damping performances to instability of power systems. To address this problem, this paper proposes a resilient wide-area damping control (RWADC) for inter-area oscillation based on a secure networked predictive control (SNPC), which is combined with information technology security system (ITSS) and the resilient control scheme based on networked predictive control (NPC). The ITSS including data encryption, data decryption and deception attack detection, is designed to guarantee data confidentiality, integrity, and authenticity. This security system is based on Data Encryption Standard (DES) and Message Digest Algorithm (MD5). The NPC part is used to provide optimal control sequences and compensate the impact of communication constraints and deception attacks, which includes modified generalized predictive control (MGPC), network delay compensator (NDC), and model identifier. Case studies are undertaken on the 16-machine 68-bus AC/DC hybrid power system. Simulation results show that the proposed RWADC can suppress inter-area oscillations, provide better damping performances than those of the conventional and robust WADC over different operating conditions and compensate adverse effects caused by deception attacks actively.
引用
收藏
页码:4238 / 4249
页数:12
相关论文
共 50 条
  • [1] Wide-area robust control for damping multiple inter-area oscillations
    Chen, He
    Chen, Jing
    Chen, Xiying
    Bai, Hong
    Guo, Zhizhong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 627 - +
  • [2] Wide-area robust H∞ control with pole placement for damping inter-area oscillations
    Chen, He
    Bai, Hong
    Liu, Ming
    Guo, Zhizhong
    2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, : 2101 - +
  • [3] Online PMU-Based Wide-Area Damping Control for Multiple Inter-Area Modes
    Zenelis, Ilias
    Wang, Xiaozhe
    Kamwa, Innocent
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (06) : 5451 - 5461
  • [4] Measurement-based wide-area damping of inter-area oscillations based on MIMO identification
    Thakallapelli, Abilash
    Kamalasadan, Sukumar
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (13) : 2464 - 2475
  • [5] Resilient Adaptive Wide-Area Damping Control to Mitigate False Data Injection Attacks
    Zhao, Yifan
    Yao, Wei
    Nan, Jiajun
    Fang, Jiakun
    Ai, Xiaomeng
    Wen, Jinyu
    Cheng, Shijie
    IEEE SYSTEMS JOURNAL, 2021, 15 (04): : 4831 - 4842
  • [6] Resilient Wide-Area Damping Control Using GrHDP to Tolerate Communication Failures
    Shen, Yu
    Yao, Wei
    Wen, Jinyu
    He, Haibo
    Jiang, Lin
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (03) : 2547 - 2557
  • [7] A model-free sparse wide-area damping controller for inter-area oscillations
    Zenelis, Ilias
    Wang, Xiaozhe
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 136
  • [8] Wide-area robust H2/H∞ control with pole placement for damping inter-area oscillations
    Chen, He
    Guo, Zhizhong
    Bai, Hong
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 518 - +
  • [9] Inter-area oscillation damping with non-synchronised wide-area power system stabiliser
    Patel, Abhilash
    Ghosh, Sandip
    Folly, Komla A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (12) : 3070 - 3078
  • [10] Resilient Wide-Area Damping Control to Mitigate Strong Cyber Attack: A Multiple-Controller Switching Approach
    Zhao, Yifan
    Yao, Wei
    Zhang, Chuan-Ke
    Ai, Xiaomeng
    Wen, Jinyu
    IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (03) : 2326 - 2337