EVALUATION OF THE MARGINAL FIT OF A ZIRCONIA CERAMIC COMPUTER-AIDED MACHINED (CAM) CROWN SYSTEM

被引:157
作者
Baig, Mirza Rustum [1 ]
Tan, Keson Beng-Choon [2 ]
Nicholls, Jack I. [3 ]
机构
[1] Univ Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
[2] Natl Univ Singapore, Dept Restorat Dent, Fac Dent, Singapore 117548, Singapore
[3] Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA 98195 USA
关键词
FIXED DENTAL PROSTHESES; PROCERA ALLCERAM CROWNS; PARTIAL DENTURES; IN-CERAM; MECHANICAL-PROPERTIES; FRACTURE-TOUGHNESS; FLEXURAL STRENGTH; CAD/CAM CROWNS; CORE MATERIALS; FINISH LINES;
D O I
10.1016/S0022-3913(10)60128-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The marginal fit of crowns is a concern for clinicians, and there is no conclusive evidence of any one margin configuration yielding better results than others in terms of marginal fit. Purpose. The purpose of this study was to evaluate the marginal fit with respect to gap and overhang of Y-TZP (yttria-stabilized tetragonal zirconia polycrystals) ceramic crowns and compare them with lithium disilicate pressable and complete metal crowns. The influence of margin configuration on the marginal fit was also evaluated. Material and methods. Impressions were made of premolar dies prepared with shoulders or chamfers with a 20-degree total occlusal convergence (n=30). Type IV stone dies were then distributed into test groups (n=10) for the fabrication of Cercon Y-TZP, IPS Empress II, and complete metal (noble type IV alloy) crowns. The crowns were then subjected to marginal gap and overhang evaluation at 6 designated margin locations using a computerized digital image analysis system. The data were calculated and statistically analyzed using 2-way ANOVA and Bonferroni post hoc tests (alpha=.05). Results. The overall mean (SD) marginal gap at the marginal opening for the crowns was 66.4 (42.2) mu m for Cercon, 36.6 (32.1) mu m for IPS Empress II, and 37.1 (22.3) mu m for complete metal (control). Overall mean (SD) overhang was -15.2 (47.5) mu m for Cercon, -22.1 (34.7) mu m for IPS Empress II, and 30.9 (31.3) mu m for complete metal (control). The ANOVA revealed significant effects by material and no significant effects by marginal configuration for marginal gap. There were significant differences in the marginal overhang values between the 2 margins, but no significant differences were found between the material groups for overhang. Conclusions. The Cercon system showed significantly larger (P<.05) marginal gaps than both the IPS Empress II and complete metal (control) crowns, but no significant differences were found in marginal overhang among the 3 material groups. There was no significant difference in marginal gap between the 2 margin configurations, namely, chamfer and shoulder, for all test groups; however, there were significant differences (P<.05) in marginal overhang values between chamfer and shoulder margins. (J Prosthet Dent 2010;104:216-227)
引用
收藏
页码:216 / 227
页数:12
相关论文
共 56 条
  • [1] Microtensile bond strength of different components of core veneered all-ceramic restorations
    Aboushelib, MN
    de Jager, N
    Kleverlaan, CJ
    Feiler, AJ
    [J]. DENTAL MATERIALS, 2005, 21 (10) : 984 - 991
  • [2] Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems
    Aboushelib, Moustafa N.
    de Jager, Niek
    Kleverlaan, Cornelis J.
    Feilzer, Albert J.
    [J]. DENTAL MATERIALS, 2007, 23 (08) : 952 - 959
  • [3] Akbar Jaber Hussain, 2006, J Prosthodont, V15, P155, DOI 10.1111/j.1532-849X.2006.00095.x
  • [4] Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    Attia, A
    Abdelaziz, KM
    Freitag, S
    Kern, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) : 117 - 123
  • [5] Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
    Balkaya, MC
    Cinar, A
    Pamuk, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (04) : 346 - 355
  • [6] Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth
    Beschnidt, SM
    Strub, JR
    [J]. JOURNAL OF ORAL REHABILITATION, 1999, 26 (07) : 582 - 593
  • [7] Chan C, 1989, Quintessence Int, V20, P189
  • [8] Translucency and biaxial flexural strength of four ceramic core materials
    Chen, Ya-Ming
    Smales, Roger J.
    Yip, Kevin H. -K.
    Sung, Wei-Jia
    [J]. DENTAL MATERIALS, 2008, 24 (11) : 1506 - 1511
  • [9] Effect of finish line variants on marginal accuracy and fracture strength of ceramic optimized polymer/fiber-reinforced composite crowns
    Cho, LR
    Choi, JM
    Yi, YJ
    Park, CJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (06) : 554 - 560
  • [10] Coli P, 2004, INT J PROSTHODONT, V17, P59