A Fully Implanted Intramuscular Bipolar Myoelectric Signal Recording Electrode

被引:16
|
作者
Memberg, William D. [1 ,3 ]
Stage, Thomas G. [2 ,3 ]
Kirsch, Robert F. [1 ,2 ,3 ]
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] Louis Stokes VA Med Ctr, Cleveland, OH USA
[3] Cleveland FES Ctr, Cleveland, OH USA
来源
NEUROMODULATION | 2014年 / 17卷 / 08期
关键词
electrode; EMG; functional electrical stimulation (FES); implantable system; myoelectric recording; NEUROPROSTHESIS; STIMULATION; PROSTHESES;
D O I
10.1111/ner.12165
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectivesThe objective of this study is to develop a fully implanted, intramuscular, bipolar, myoelectric signal (IM-MES) recording electrode for functional electrical stimulation (FES), prosthetic myoelectric control, and other permanently implantable systems. Materials and MethodsAn existing fully implanted intramuscular stimulating electrode was modified at each end to allow bipolar recording. The design change also required a modification of the implantation method. Mechanical and in vivo testing was performed on the novel components of the electrode. The first clinical application also is described. ResultsThe electrode design modifications did not create any areas of excess mechanical strain on the wires at the distal end where the leads were wound into electrode surfaces. In vivo testing showed that the IM-MES electrode recorded myoelectric signals that were equivalent to an existing epimysial MES electrode. The modified implantation method was simple to implement. The IM-MES electrode was used in an upper extremity FES system in an individual with a spinal cord injury and provided signals that were suitable for a command signal. ConclusionsA fully implanted, bipolar intramuscular recording electrode (IM-MES) was developed. Implantation of the IM-MES is straightforward, and almost any muscle can be targeted. Testing has been performed to demonstrate the suitability of the IM-MES electrode for clinical use. Initial clinical applications were successful.
引用
收藏
页码:794 / 799
页数:6
相关论文
共 50 条
  • [1] Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
    Weir, Richard E. Ff
    Troyk, Phil R.
    DeMichele, Glen A.
    Kerns, Douglas A.
    Schorsch, Jack F.
    Maas, Huub
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (01) : 159 - 171
  • [2] A comparison of surface and intramuscular myoelectric signal classification
    Hargrove, Levi J.
    Englehart, Kevin
    Hudgins, Bernard
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (05) : 847 - 853
  • [3] STATISTICS OF MYOELECTRIC SIGNAL FROM MONOPOLAR AND BIPOLAR ELECTRODES
    PARKER, PA
    SCOTT, RN
    MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (05): : 591 - 596
  • [4] Statistics of the myoelectric signal from monopolar and bipolar electrodes
    Parker, P.A.
    Scott, R.N.
    1600, (11):
  • [5] A SIMPLIFIED FULLY IMPLANTED BIPOLAR VLSI TECHNOLOGY
    KO, WC
    GWO, TC
    YEUNG, PH
    RADIGAN, SJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1983, 30 (03) : 236 - 239
  • [6] Design and Testing of Stimulation and Myoelectric Recording Modules in an Implanted Distributed Neuroprosthetic System
    Makowski, Nathaniel S.
    Campean, Alexandru
    Lambrecht, Joris M.
    Buckett, James R.
    Coburn, James D.
    Hart, Ronald L.
    Miller, Michael E.
    Montague, Fred W.
    Crish, Timothy
    Fu, Michael J.
    Kilgore, Kevin L.
    Peckham, P. Hunter
    Smith, Brian
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (02) : 281 - 293
  • [7] FULLY ION-IMPLANTED BIPOLAR-TRANSISTORS
    PAYNE, RS
    SCAVUZZO, RJ
    OLSON, KH
    NACCI, JM
    MOLINE, RA
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1974, ED21 (04) : 273 - 278
  • [8] Electrode Design for Electrotactile Feedback With Reduced Interference to Myoelectric Signal
    Yang, Dapeng
    Qi Huang
    Jiang, Zainan
    Li Jianga
    IEEE SENSORS JOURNAL, 2021, 21 (14) : 16350 - 16358
  • [9] THE SPATIAL INTEGRATION EFFECT OF SURFACE ELECTRODE DETECTING MYOELECTRIC SIGNAL
    HELAL, JN
    BOUISSOU, P
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (11) : 1161 - 1167
  • [10] MRI Induced Heating for Fully Implanted, Partially Implanted and Minimum Implanted Medical Electrode Leads
    Zeng, Qi
    Zheng, Jianfeng
    Chen, Ji
    2015 31st International Review of Progress in Applied Computational Electromagnetics (ACES) Vol 31, 2015,