Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia

被引:11
|
作者
Zhang, Xiaoming [1 ,2 ]
Plow, Ela [2 ]
Ranganthan, Vinoth [3 ]
Huang, Honglian [1 ,2 ]
Schmitt, Melissa [1 ]
Nemunaitis, Gregory [4 ]
Kelly, Clay [1 ]
Frost, Frederick [2 ]
Lin, Vernon [1 ,2 ]
机构
[1] Louis Stokes Cleveland Vet Affairs Med Ctr, Cleveland, OH 44106 USA
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH 44106 USA
[3] Dabir Surfaces Inc, Southfield, MI USA
[4] Metrohlth Med Ctr, Cleveland, OH USA
关键词
SPINAL-CORD-INJURY; PHRENIC-NERVE STIMULATION; ELECTRICAL ACTIVATION; INTERCOSTAL MUSCLES; ARTIFICIAL-VENTILATION; PULMONARY-FUNCTION; RESTORING COUGH; DOGS; DIAPHRAGM; MECHANICS;
D O I
10.1016/j.pmrj.2016.01.016
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. Objective: To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. Design: A prospective before and after trial. Setting: FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Participants: Six persons with tetraplegia. Method: Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Main Outcome Measurements: Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). Results: After 6 weeks of conditioning, the main outcome measurements (mean +/- standard error) were as follows: MIP, 89.6 +/- 7.3 cm H2O; IRV, 1.90 +/- 0.34 L; PIF, 302.4 +/- 36.3 L/min; MEP, 67.4 +/- 11.1 cm H2O; ERV, 0.40 +/- 0.06 L; and PEF, 372.4 +/- 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. Conclusion: FMS conditioning of the inspiratory and expiratory muscles improved voluntary inspiratory and expiratory functions. FMS may be a noninvasive technology for respiratory muscle training in persons with tetraplegia.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 50 条
  • [21] Analysis of inspiratory and expiratory muscles using ultrasound in rats: A reproducible and non-invasive tool to study respiratory function
    Fayssoil, Abdallah
    Michel-Flutot, Pauline
    Lofaso, Frederic
    Carlier, Robert
    El Hajjam, Mostafa
    Vinit, Stephane
    Mansart, Arnaud
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2021, 285
  • [22] Acute Effects of Inspiratory Loads and Interfaces on Breathing Pattern and Activity of Respiratory Muscles in Healthy Subjects
    Medeiros da Fonseca, Jessica Danielle
    Resqueti, Vanessa Regiane
    Benicio, Kadja
    Fregonezi, Guilherme
    Aliverti, Andrea
    FRONTIERS IN PHYSIOLOGY, 2019, 10
  • [23] Functional electrical stimulation in paralyzed respiratory muscles: International workshop in Hamburg, Germany
    Exner, G
    Baer, GA
    NEUROMODULATION, 2000, 3 (04): : 211 - 217
  • [24] Quantitative comparison of grasp and release abilities with and without functional neuromuscular stimulation in adolescents with tetraplegia
    Smith, BT
    Mulcahey, MJ
    Betz, RR
    PARAPLEGIA, 1996, 34 (01): : 16 - 23
  • [25] Activating effective functional hand movements in individuals with complete tetraplegia through neural stimulation
    Coste, Christine Azevedo
    William, Lucie
    Fonseca, Lucas
    Hiairrassary, Arthur
    Andreu, David
    Geffrier, Antoine
    Teissier, Jacques
    Fattal, Charles
    Guiraud, David
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Force-pain relationship in functional magnetic and electrical stimulation of subjects with paresis and preserved sensation
    Szecsi, J.
    Goetz, S.
    Poellmann, W.
    Straube, A.
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (09) : 1589 - 1597
  • [27] Paired pulse transcranial magnetic stimulation in the assessment of biceps voluntary activation in individuals with tetraplegia
    Roumengous, Thibault
    Thakkar, Bhushan
    Peterson, Carrie L. L.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [28] IMPROVING FUNCTIONAL ELECTRICAL STIMULATION DRIVEN CYCLING BY PROPER SYNCHRONIZATION OF THE MUSCLES
    Pilissy, Tamas
    Klauber, Andras
    Fazekas, Gabor
    Laczko, Jozsef
    Szecsi, Johann
    IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2008, 61 (5-6): : 162 - 167
  • [29] Functional electrical stimulation instead of surgery?: Improvement of grasping function with FES in a patient with C5 tetraplegia
    Pfurtscheller, J
    Rupp, R
    Müller, GR
    Fabsits, E
    Korisek, G
    Gerner, HJ
    Pfurtscheller, G
    UNFALLCHIRURG, 2005, 108 (07): : 587 - 590
  • [30] Effects of Long-Term Paired Associative Stimulation on Strength of Leg Muscles and Walking in Chronic Tetraplegia: A Proof-of-Concept Pilot Study
    Rodionov, Andrei
    Savolainen, Sarianna
    Kirveskari, Erika
    Makela, Jyrki P.
    Shulga, Anastasia
    FRONTIERS IN NEUROLOGY, 2020, 11