Comparison of Outcomes of Glaucoma Drainage Implant Surgery With or Without Prior Failed Trabeculectomy

被引:4
作者
Dawson, Emily F. [1 ]
Rosenberg, Nicole C. [1 ,2 ]
Meyer, Alissa M. [1 ]
Culpepper, Brady E. [1 ]
Bolch, Charlotte A. [1 ]
Wilson, Mary K. [1 ]
Nguyen, Phuong T. [1 ]
Rodgers, Cooper D. [1 ]
Smith, Ryan J. [1 ]
Blake, Charles R. [1 ]
Sherwood, Mark B. [1 ]
机构
[1] Univ Florida, Dept Ophthalmol, Gainesville, FL USA
[2] Edward Via Coll Osteopath Med, Spartanburg, SC USA
关键词
glaucoma drainage device; trabeculectomy surgery; intraocular pressure; glaucoma; TUBE; PRESSURE;
D O I
10.1097/IJG.0000000000001852
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: A comparison of 186 glaucoma patients with mixed diagnoses who underwent nonvalved glaucoma drainage device (GDD) implant surgery showed similar long-term intraocular pressure (IOP), medication, and visual acuity (VA) outcomes between those with prior failed trabeculectomy surgery versus those without. Purpose: The purpose of this study was to evaluate whether prior failed trabeculectomy adversely affects the outcome of glaucoma tube surgery. Patients and Methods: A total of 186 eyes of 186 patients who underwent a nonvalved GDD implant surgery by a single surgeon between 1996 and 2015 at a University practice were included. Patients were of mixed diagnoses and over 18 years old. Before the GDD surgery, 65 had a previous failed glaucoma filtering surgery and 121 had no prior glaucoma surgery. Demographic information, preoperative and postoperative IOP, medication, VA, and complications were collected from chart review. Results: No significant difference was noted in mean IOP and mean medication use (13.0 and 12.6 mm Hg on 2.0 and 1.7 medication classes at 5 y postoperatively, respectively), mean VA and change in VA from baseline, or numbers of complications (P>0.05), between eyes that had a prior failed filtration surgery and those that had not. Kaplan-Meier plots for failure over 5 years using a lower limit of <5 mm Hg and an upper limit of >= 18, >= 15, or >= 12 mm Hg did not show a significant difference between groups. Subanalyses were performed to examine only primary glaucoma eyes and results were similar. Further group subanalyses comparing those with baseline IOP >= 25 or <25 mm Hg, age 65 and above or below 65 years and those specifically with Baerveldt 350 mm(2) implants also did not show significant differences. Conclusion: Prior failed filtration surgery does not appear to affect the outcome of future GDD surgery.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [41] Intermediate-term outcomes of Aurolab aqueous drainage implant in refractory paediatric glaucoma
    Puthuran, George Varghese
    Palmberg, Paul Frederic
    Wijesinghe, Hiruni Kaushalya
    Pallamparthy, Srilekha
    Krishnadas, S. R.
    Robin, Alan L.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (07) : 962 - 966
  • [42] Outcomes of Ahmed Glaucoma Drainage Implant in Eyes With Glaucoma Secondary to Iridocorneal Endothelial Syndrome
    Gebremichael, Bayu G.
    Mohamed, Ashik
    Chaurasia, Sunita
    Senthil, Sirisha
    JOURNAL OF GLAUCOMA, 2020, 29 (07) : 567 - 571
  • [43] Outcomes of Trabeculectomy and Glaucoma Drainage Devices for Elevated Intraocular Pressure After Penetrating Keratoplasty
    Yakin, Mehmet
    Eksioglu, Umit
    Yalniz-Akkaya, Zuleyha
    Uzman, Selma
    Singar-Ozdemir, Evin
    Gultekin, Kemal
    Demirok, Gulizar
    Yalvac, Ilgaz
    Ornek, Firdevs
    Burcu, Ayse
    CORNEA, 2018, 37 (06) : 705 - 711
  • [44] Strabismus surgery outcomes in eyes with glaucoma drainage devices
    Osigian, Carla J.
    Cavuoto, Kara M.
    Rossetto, Julia D.
    Sayed, Mohamed
    Grace, Sara
    Chang, Ta C.
    Capo, Hilda
    JOURNAL OF AAPOS, 2017, 21 (02): : 103 - 106
  • [45] Primary implantation of glaucoma drainage device in secondary glaucoma: Comparison of Aurolab aqueous drainage implant versus Ahmed glaucoma valve
    Pathak-Ray, Vanita
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (SUPPL 2) : S327 - S333
  • [46] Glaucoma Drainage Implant Surgery and Ocular Surface Transplant Graft Preservation
    Aref, Ahmad A.
    Sivaraman, Kavitha R.
    Djalilian, Ali R.
    SEMINARS IN OPHTHALMOLOGY, 2015, 30 (03) : 210 - 213
  • [47] Effect of glaucoma drainage implant surgery on corneal topography: a prospective study
    Koivusalo, Riku
    Valimaki, Juha
    ACTA OPHTHALMOLOGICA, 2020, 98 (03) : 305 - 309
  • [48] Comparison of Quality of Life in Patients with Glaucoma Undergoing Shunt Surgery and Trabeculectomy
    Heidi, Parisa
    Khaniki, Saeedeh Hajebi
    Pour, Hosna Delarami
    Esmaeili, Alireza
    Alesheikh, Ali
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 490 - 497
  • [49] Baerveldt implant versus trabeculectomy as the first filtering surgery for uncontrolled primary congenital glaucoma: a randomized clinical trial
    Rolim-de-Moura, Christiane
    Esporcatte, Bruno L. B.
    Netto, Camila F.
    Paranhos Jr, Augusto
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2020, 83 (03) : 215 - 224
  • [50] Comparison of Ahmed Versus Baerveldt Implant Outcomes in Malayan Glaucoma Patients
    Artini, Widya
    Mustafa, Syukri
    Octariana, Virna D.
    Suryono, Astrianda
    MAKARA JOURNAL OF HEALTH RESEARCH, 2018, 22 (03): : 115 - 120