Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis

被引:57
作者
Calvert, Graham C. [1 ]
Lawrence, Brandon D. [1 ]
Abtahi, Amir M. [1 ]
Bachus, Kent N. [1 ]
Brodke, Darrel S. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, Orthopaed Bioengn Lab, Salt Lake City, UT 84108 USA
关键词
cortical screw; pedicle screw; instrumentation; failed fixation; pullout strength; stiffness; rescue; salvage; arthrodesis; lumbar spine; technique; CEMENT AUGMENTATION; STRAIGHT-FORWARD; FIXATION; BONE; REVISION; POLYMETHYLMETHACRYLATE; STRENGTH; SALVAGE;
D O I
10.3171/2014.10.SPINE14371
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT Cortical trajectory screw constructs, developed as an alternative to pedicle screw fixation for the lumbar spine, have similar in vitro biomechanics. The possibility of one screw path having the ability to rescue the other in a revision scenario holds promise but has not been evaluated. The objective in this study was to investigate the biomechanical properties of traditional pedicle screws and cortical trajectory screws when each was used to rescue the other in the setting of revision. METHODS Ten fresh-frozen human lumbar spines were instrumented at L3-4, 5 with cortical trajectory screws and 5 with pedicle screws. Construct stiffness was recorded in flexion/extension, lateral bending, and axial rotation. The L-3 screw pullout strength was tested to failure for each specimen and salvaged with screws of the opposite trajectory. Mechanical stiffness was again recorded. The hybrid rescue trajectory screws at L-3 were then tested to failure. RESULTS Cortical screws, when used in a rescue construct, provided stiffness in flexion/extension and axial rotation similar to that-provided by the initial pedicle screw construct prior to failure. The rescue pedicle screws provided stiffness similar to that provided by the primary cortical screw construct in flexion/extension, lateral bending, and axial rotation. In pullout testing, cortical rescue screws retained 60% of the original pedicle screw pullout strength, whereas pedicle rescue screws retained 65% of the original cortical screw pullout strength. CONCLUSIONS Cortical trajectory screws, previously studied as a primary mode of fixation, may also be used as a rescue option in the setting of a failed or compromised pedicle screw construct in the lumbar spine. Likewise, a standard pedicle screw construct may rescue a compromised cortical screw track. Cortical and pedicle screws each retain adequate construct stiffness and pullout strength when used for revision at the same level.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 31 条
  • [11] Structural characteristics of the pedicle and its role in screw stability
    Hirano, T
    Hasegawa, K
    Takahashi, HE
    Uchiyama, S
    Hara, T
    Washio, T
    Sugiura, T
    Yokaichiya, M
    Ikeda, M
    [J]. SPINE, 1997, 22 (21) : 2504 - 2509
  • [12] Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body
    Hu, Ming-Hsien
    Wu, Hung Ta H.
    Chang, Ming-Chau
    Yu, Wing-Kuang
    Wang, Shih-Tien
    Liu, Chien-Lin
    [J]. EUROPEAN SPINE JOURNAL, 2011, 20 (08) : 1281 - 1288
  • [13] Fate of large structural allograft for treatment of severe uncontained glenoid bone deficiency
    Iannotti, Joseph P.
    Frangiamore, Salvatore J.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (06) : 765 - 771
  • [14] Evaluation of the fixation and strength of a "rescue" revision pedicle screw
    Klein, SA
    Glassman, SD
    Dimar, JR
    Voor, MJ
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (02): : 100 - 104
  • [15] Bone Cement Augmentation in the Prevention of Adjacent Segment Failure After Multilevel Adult Deformity Fusion
    Lattig, Friederike
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (06): : 439 - 443
  • [16] Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: A biomechanical analysis
    Lehman, RA
    Polly, DW
    Kuklo, TR
    Cunningham, B
    Kirk, KL
    Belmont, PJ
    [J]. SPINE, 2003, 28 (18) : 2058 - 2065
  • [17] Use of the anatomic trajectory for thoracic pedicle screw salvage after failure/violation using the straight-forward technique: A biomechanical analysis
    Lehman, RA
    Kuklo, TR
    [J]. SPINE, 2003, 28 (18) : 2072 - 2077
  • [18] Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine
    Lotz, JC
    Hu, SS
    Chiu, DFM
    Yu, M
    Colliou, O
    Poser, RD
    [J]. SPINE, 1997, 22 (23) : 2716 - 2723
  • [19] In Vivo Analysis of Insertional Torque During Pedicle Screwing Using Cortical Bone Trajectory Technique
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Kato, Takashi
    Imabayashi, Hideaki
    Asazuma, Takashi
    Nemoto, Koichi
    [J]. SPINE, 2014, 39 (04) : E240 - E245
  • [20] Morphometric Measurement of Cortical Bone Trajectory for Lumbar Pedicle Screw Insertion Using Computed Tomography
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Nemoto, Osamu
    Imabayashi, Hideaki
    Asazuma, Takashi
    Nemoto, Koichi
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (06): : E248 - E253