Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis

被引:57
作者
Calvert, Graham C. [1 ]
Lawrence, Brandon D. [1 ]
Abtahi, Amir M. [1 ]
Bachus, Kent N. [1 ]
Brodke, Darrel S. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, Orthopaed Bioengn Lab, Salt Lake City, UT 84108 USA
关键词
cortical screw; pedicle screw; instrumentation; failed fixation; pullout strength; stiffness; rescue; salvage; arthrodesis; lumbar spine; technique; CEMENT AUGMENTATION; STRAIGHT-FORWARD; FIXATION; BONE; REVISION; POLYMETHYLMETHACRYLATE; STRENGTH; SALVAGE;
D O I
10.3171/2014.10.SPINE14371
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT Cortical trajectory screw constructs, developed as an alternative to pedicle screw fixation for the lumbar spine, have similar in vitro biomechanics. The possibility of one screw path having the ability to rescue the other in a revision scenario holds promise but has not been evaluated. The objective in this study was to investigate the biomechanical properties of traditional pedicle screws and cortical trajectory screws when each was used to rescue the other in the setting of revision. METHODS Ten fresh-frozen human lumbar spines were instrumented at L3-4, 5 with cortical trajectory screws and 5 with pedicle screws. Construct stiffness was recorded in flexion/extension, lateral bending, and axial rotation. The L-3 screw pullout strength was tested to failure for each specimen and salvaged with screws of the opposite trajectory. Mechanical stiffness was again recorded. The hybrid rescue trajectory screws at L-3 were then tested to failure. RESULTS Cortical screws, when used in a rescue construct, provided stiffness in flexion/extension and axial rotation similar to that-provided by the initial pedicle screw construct prior to failure. The rescue pedicle screws provided stiffness similar to that provided by the primary cortical screw construct in flexion/extension, lateral bending, and axial rotation. In pullout testing, cortical rescue screws retained 60% of the original pedicle screw pullout strength, whereas pedicle rescue screws retained 65% of the original cortical screw pullout strength. CONCLUSIONS Cortical trajectory screws, previously studied as a primary mode of fixation, may also be used as a rescue option in the setting of a failed or compromised pedicle screw construct in the lumbar spine. Likewise, a standard pedicle screw construct may rescue a compromised cortical screw track. Cortical and pedicle screws each retain adequate construct stiffness and pullout strength when used for revision at the same level.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 31 条
  • [1] The biomechanical contribution of varying posterior constructs following anterior thoracolumbar corpectomy and reconstruction Laboratory investigation
    Bishop, Frank S.
    Samuelson, Mical M.
    Finn, Michael A.
    Bachus, Kent N.
    Brodke, Darrel S.
    Schmidt, Meic H.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (02) : 234 - 239
  • [2] Brodke D S, 2001, Spine J, V1, P373, DOI 10.1016/S1529-9430(01)00116-4
  • [3] Anterior cervical fixation: Analysis of load-sharing and stability with use of static and dynamic plates
    Brodke, Darrel S.
    Klimo, Paul, Jr.
    Bachus, Kent N.
    Braun, John T.
    Dailey, Andrew T.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (07) : 1566 - 1573
  • [4] Dynamic cervical plates - Biomechanical evaluation of load sharing and stiffness
    Brodke, DS
    Gollogly, S
    Mohr, RA
    Nguyen, BK
    Dailey, AT
    Bachus, KN
    [J]. SPINE, 2001, 26 (12) : 1324 - 1329
  • [5] Enhancing Pedicle Screw Fixation in the Lumbar Spine Using Allograft Bone Plug Interference Fixation
    Chrea, Bopha
    Malempati, Harsha
    Campbell, Jeffrey R.
    Khan, Sonja
    Ching, Randal P.
    Lee, Michael J.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (03): : E81 - E87
  • [6] Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone
    Derincek, A
    Wu, C
    Mehbod, A
    Transfeldt, EE
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (04): : 286 - 291
  • [7] COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS
    ESSES, SI
    SACHS, BL
    DREYZIN, V
    [J]. SPINE, 1993, 18 (15) : 2231 - 2239
  • [8] Biomechanical analysis of a new concept - An add-on dynamic extension plate for adjacent-level anterior cervical fusion
    Fassett, DR
    Apfelbaum, R
    Clark, R
    Bachus, KN
    Brodke, DS
    [J]. SPINE, 2005, 30 (22) : 2523 - 2529
  • [9] Two-Level Noncontiguous Versus Three-Level Anterior Cervical Discectomy and Fusion A Biomechanical Comparison
    Finn, Michael A.
    Samuelson, Mical M.
    Bishop, Frank
    Bachus, Kent N.
    Brodke, Darrel S.
    [J]. SPINE, 2011, 36 (06) : 448 - 453
  • [10] Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty
    Finn, Michael A.
    Brodke, Darrel S.
    Daubs, Michael
    Patel, Alpesh
    Bachus, Kent N.
    [J]. EUROPEAN SPINE JOURNAL, 2009, 18 (10) : 1520 - 1527