Enantiospecific determination of arotinolol in rat plasma by LC-MS/MS: Application to a stereoselective pharmacokinetic study

被引:11
作者
Qian, Zheyuan [1 ,2 ]
Xu, Yanhai [1 ]
Zheng, Leyi [1 ]
Zhang, Jingbo [1 ]
Hong, Zhanying [1 ]
Shen, Xiaohang [2 ]
机构
[1] Second Mil Med Univ, Sch Pharm, Shanghai Key Lab Phamaceut Metabol Res, Shanghai 200433, Peoples R China
[2] WuXi AppTec Co Ltd, Bioanalyt Serv, Shanghai 200131, Peoples R China
关键词
LC-MS/MS; Arotinolol enantiomers; Stereoselective pharmacokinetics; LIQUID-CHROMATOGRAPHIC DETERMINATION; BIOLOGICAL SAMPLES; MAIN METABOLITE; AC-623; PHASE; DRUGS;
D O I
10.1016/j.jpba.2014.09.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated for quantification of arotinolol enantiomers in rat plasma using haloperidol as the internal standard. After solid phase extraction of 50.0 mu L rat plasma in 96 well plate, a baseline resolution of arotinolol enantiomers was achieved on a CHIRALPAK AD-H column using the mobile phase of n-hexane and ethanol in 0.02% diethylamine (20:80, v/v) at a flow rate of 0.550 mL/min within 11.0 min. Acquisition of mass spectrometric data was performed on a triple-quadrupole mass spectrometer in multiple-reaction-monitoring (MRM) mode with an ESI source using the transition m/z 372.1 -> 316.1 for (+/-)-arotinolol and m/z 376.1 -> 165.1 for haloperidol. The calibration curves of both enantiomers were linear over the range of 1.00-200.0 ng/mL (r(2) > 0.992) and the lower limit of quantification was 1.00 ng/mL. Intra- and inter-day precision ranged from 5.6% to 8.9% for R-( -)-arotinolol and 4.6-7.4% for S-(+)-arotinolol. Accuracy varied from 0.0% to 7.0% for R-(-)-arotinolol and 5.0-10.0% for S-(+)-arotinolol. For R-(-)-arotinolol, the recovery ranged from 87.2% to 99.2% and the matrix factor was 1.03-1.09; for S-(+)-arotinolol, the recovery ranged from 88.0% to 92.4% and the matrix factor was 0.84-0.95, both were not concentration dependent. The method was demonstrated with acceptable accuracy, precision and specificity for the determination of arotinolol enantiomers and has been successfully applied to a stereoselective pharmacokinetic study. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [41] Quantification of β-eudesmol in rat plasma using LC-MS/MS and its application to a pharmacokinetic study
    Jiang, Ligang
    Zhang, Chunyang
    Li, Haiping
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (12)
  • [42] Determination of ulixertinib in mice plasma by LC-MS/MS and its application to a pharmacokinetic study in mice
    Kumar, Rajinish
    Suresh, P. S.
    Rudresh, G.
    Zainuddin, Mohd
    Dewang, Purushottam
    Kethiri, Ragahava Reddy
    Rajagopal, Sriram
    Mullangi, Ramesh
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 125 : 140 - 144
  • [43] Determination of geniposidic acid in rat plasma by LC-MS/MS and its application to in vivo pharmacokinetic studies
    Zheng, Xia
    Huang, Xiao-Tao
    Li, Neng
    Li, Ying-Yi
    Mi, Sui-Qing
    Wang, Ning-Sheng
    Liu, Chang-Hui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 887 : 138 - 142
  • [44] Quantification of complanatoside A in rat plasma using LC-MS/MS and its application to a pharmacokinetic study
    Li, Nan
    Liu, Yue
    Cao, Yuchen
    Wei, Zhouxia
    Pang, Li
    Wang, Jianmeng
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 888 - 893
  • [45] Determination of pinostrobin in rat plasma by LC-MS/MS: Application to pharmacokinetics
    Hua, Xin
    Fu, Yu-Jie
    Zu, Yuan-Gang
    Zhang, Lin
    Wang, Wei
    Luo, Meng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (04) : 841 - 845
  • [46] Rapid and Sensitive Determination of Timosaponin AIII in Rat Plasma by LC-MS/MS and Its Pharmacokinetic Application
    Liu, Yanping
    Pu, Yiqiong
    Zhang, Tong
    Ding, Yue
    Wang, Bing
    Cai, Zhenzhen
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (02) : 3656 - 3670
  • [47] Determination of mitragynine in rat plasma by LC-MS/MS: Application to pharmacokinetics
    de Moraes, Natalia Valadares
    Correa Moretti, Raquel Alves
    Furr, Edward B., III
    McCurdy, Christopher R.
    Lanchote, Vera Lucia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (24): : 2593 - 2597
  • [48] A sensitive LC-MS/MS method for determination of levamisole in human plasma: Application to pharmacokinetic study
    Tong, Liping
    Ding, Likun
    Li, Yan
    Wang, Zhirui
    Wang, Jingwen
    Liu, Yu
    Yang, Lin
    Wen, Aidong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 299 - 303
  • [49] Simultaneous quantification of ruxolitinib and nilotinib in rat plasma by LC-MS/MS: Application to a pharmacokinetic study
    Veeraraghavan, Sridhar
    Thappali, Satheeshmanikandan
    Viswanadha, Srikant
    Chennupati, Sandhyarani
    Nalla, Santhoshkumar
    Golla, Manikantakumar
    Vakkalanka, Swaroopkumar
    Rangasamy, Manivannan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 94 : 125 - 131
  • [50] Development of an LC-MS/MS method for simultaneous determination of memantine and donepezil in rat plasma and its application to pharmacokinetic study
    Bhateria, Manisha
    Ramakrishna, Rachumallu
    Pakala, Dora Babu
    Bhatta, Rabi Sankar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1001 : 131 - 139