Enantiospecific determination of arotinolol in rat plasma by LC-MS/MS: Application to a stereoselective pharmacokinetic study

被引:11
|
作者
Qian, Zheyuan [1 ,2 ]
Xu, Yanhai [1 ]
Zheng, Leyi [1 ]
Zhang, Jingbo [1 ]
Hong, Zhanying [1 ]
Shen, Xiaohang [2 ]
机构
[1] Second Mil Med Univ, Sch Pharm, Shanghai Key Lab Phamaceut Metabol Res, Shanghai 200433, Peoples R China
[2] WuXi AppTec Co Ltd, Bioanalyt Serv, Shanghai 200131, Peoples R China
关键词
LC-MS/MS; Arotinolol enantiomers; Stereoselective pharmacokinetics; LIQUID-CHROMATOGRAPHIC DETERMINATION; BIOLOGICAL SAMPLES; MAIN METABOLITE; AC-623; PHASE; DRUGS;
D O I
10.1016/j.jpba.2014.09.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated for quantification of arotinolol enantiomers in rat plasma using haloperidol as the internal standard. After solid phase extraction of 50.0 mu L rat plasma in 96 well plate, a baseline resolution of arotinolol enantiomers was achieved on a CHIRALPAK AD-H column using the mobile phase of n-hexane and ethanol in 0.02% diethylamine (20:80, v/v) at a flow rate of 0.550 mL/min within 11.0 min. Acquisition of mass spectrometric data was performed on a triple-quadrupole mass spectrometer in multiple-reaction-monitoring (MRM) mode with an ESI source using the transition m/z 372.1 -> 316.1 for (+/-)-arotinolol and m/z 376.1 -> 165.1 for haloperidol. The calibration curves of both enantiomers were linear over the range of 1.00-200.0 ng/mL (r(2) > 0.992) and the lower limit of quantification was 1.00 ng/mL. Intra- and inter-day precision ranged from 5.6% to 8.9% for R-( -)-arotinolol and 4.6-7.4% for S-(+)-arotinolol. Accuracy varied from 0.0% to 7.0% for R-(-)-arotinolol and 5.0-10.0% for S-(+)-arotinolol. For R-(-)-arotinolol, the recovery ranged from 87.2% to 99.2% and the matrix factor was 1.03-1.09; for S-(+)-arotinolol, the recovery ranged from 88.0% to 92.4% and the matrix factor was 0.84-0.95, both were not concentration dependent. The method was demonstrated with acceptable accuracy, precision and specificity for the determination of arotinolol enantiomers and has been successfully applied to a stereoselective pharmacokinetic study. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [1] Enantioselective analysis of lansoprazole in rat plasma by LC-MS/MS: Application to a stereoselective pharmacokinetic study
    Luo, Linda
    Wen, Xiaoli
    Du, Yueying
    Jiang, Zhen
    Guo, Xingjie
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [2] Determination of pinostilbene in rat plasma by LC-MS/MS: Application to a pharmacokinetic study
    Chen, Wan
    Chao, Samuel
    Yeo, Ming
    Chuang, Xue Fen
    Lin, Hai-Shu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 316 - 321
  • [3] LC-MS/MS Determination of Apigenin in Rat Plasma and Application to Pharmacokinetic Study
    Zhu, Shixing
    Zhang, Jiayuan
    Lv, Zhihua
    Yu, Mingming
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2021, 22 (02) : 274 - 280
  • [4] Determination of oxaceprol in rat plasma by LC-MS/MS and its application in a pharmacokinetic study
    Gu, Jifeng
    Chen, Nianzu
    Ding, Guoqiang
    Zhang, Zhen
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 173 - 178
  • [5] Determination of dihydromyricetin in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
    Tong, Qing
    Hou, Xiaolong
    Fang, Jianguo
    Wang, Wenqing
    Xiong, Wei
    Liu, Xu
    Xie, Xuejia
    Shi, Chunyang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 : 455 - 461
  • [6] Determination of isobavachalcone in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
    Ma, Tao
    Nie, Li-Juan
    Li, Hong-Mei
    Huo, Qiang
    Zhang, Yu-Xin
    Wu, Cheng-Zhu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 107 : 50 - 55
  • [7] An LC-MS/MS method for determination of forsythiaside in rat plasma and application to a pharmacokinetic study
    Wang, Geng-Nan
    Pan, Rui-Le
    Liao, Yong-Hong
    Chen, Ying
    Tang, Jing-Tian
    Chang, Qi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (01): : 102 - 106
  • [8] Validated LC-MS/MS method for the determination of amlodipine enantiomers in rat plasma and its application to a stereoselective pharmacokinetic study
    Wang, Lijuan
    Liu, Wenxia
    Zhang, Zunjian
    Tian, Yuan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 74 - 81
  • [9] LC-MS/MS methods for the determination of edaravone and/or taurine in rat plasma and its application to a pharmacokinetic study
    Tang, Dao-quan
    Bian, Ting-ting
    Zheng, Xiao-xiao
    Li, Ying
    Wu, Xiao-wen
    Li, Yin-jie
    Du, Qian
    Jiang, Shui-shi
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (09) : 1173 - 1182
  • [10] Development of a validated LC-MS/MS method for the determination of ailanthone in rat plasma with application to pharmacokinetic study
    Chen, Ang
    Qin, Xuan
    Lu, Jian
    Yi, Zhengfang
    Liu, Mingyao
    Wang, Xin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 102 : 514 - 518