A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods

被引:16
作者
Desquins, Theo [1 ,2 ]
Bousefsaf, Frederic [1 ]
Pruski, Alain [1 ,2 ]
Maaoui, Choubeila [1 ]
机构
[1] Univ Lorraine, LCOMS, F-57000 Metz, France
[2] I Virtual, F-57000 Metz, France
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 19期
关键词
contact photoplethysmography; imaging photoplethysmography; quality index; WAVE-FORM SEGMENTATION; SIGNAL-QUALITY; ARTIFACT DETECTION; MOTION ARTIFACT; DETECTION ALGORITHM; TIME; INDEX; REDUCTION;
D O I
10.3390/app12199582
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Photoplethysmography is a method to visualize the variation in blood volume within tissues with light. The signal obtained has been used for the monitoring of patients, interpretation for diagnosis or for extracting other physiological variables (e.g., pulse rate and blood oxygen saturation). However, the photoplethysmography signal can be perturbed by external and physiological factors. Implementing methods to evaluate the quality of the signal allows one to avoid misinterpretation while maintaining the performance of its applications. This paper provides an overview on signal quality index algorithms applied to photoplethysmography. We try to provide a clear view on the role of a quality index and its design. Then, we discuss the challenges arising in the quality assessment of imaging photoplethysmography.
引用
收藏
页数:25
相关论文
共 109 条
[1]   An automatic beat detection algorithm for pressure signals [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Tsunami, D ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1662-1670
[2]  
Aliamiri Alireza, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P442, DOI 10.1109/BHI.2018.8333463
[3]  
Alian AA., 2022, Photoplethysmography: Technology, Signal Analysis and Applications, P341, DOI DOI 10.1016/B978-0-12-823374-0.00006-2
[4]  
Allen J., 2021, Photoplethysmography, DOI DOI 10.1016/B978-0-12-823374-0.00005-0
[5]   Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review [J].
Almarshad, Malak Abdullah ;
Islam, Md Saiful ;
Al-Ahmadi, Saad ;
BaHammam, Ahmed S. .
HEALTHCARE, 2022, 10 (03)
[6]   Deep recurrent neural network-based autoencoder for photoplethysmogram artifacts filtering [J].
Azar, Joseph ;
Makhoul, Abdallah ;
Couturier, Raphael ;
Demerjian, Jacques .
COMPUTERS & ELECTRICAL ENGINEERING, 2021, 92
[7]  
Bashar Syed Khairul, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P79, DOI 10.1109/BHI.2018.8333374
[8]  
Bashar SK, 2019, IEEE ENG MED BIO, P4306, DOI [10.1109/EMBC.2019.8856928, 10.1109/embc.2019.8856928]
[9]   ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction [J].
Behar, Joachim ;
Oster, Julien ;
Li, Qiao ;
Clifford, Gari D. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) :1660-1666
[10]   Probabilistic Signal Quality Metric for Reduced Complexity Unsupervised Remote Photoplethysmography [J].
Benezeth, Y. ;
Bobbia, S. ;
Nakamura, K. ;
Gomez, R. ;
Dubois, J. .
2019 13TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2019, :228-232