Noninvasive in vivo characterization of erythrocyte motion in human retinal capillaries using high-speed adaptive optics near-confocal imaging

被引:59
作者
Gu, Boyu [1 ]
Wang, Xiaolin [1 ]
Twa, Michael D. [2 ]
Tam, Johnny [3 ]
Girkin, Christopher A. [1 ]
Zhang, Yuhua [1 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Visual Sci, 1670 Univ Blvd, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Sch Optometry, Dept Optometry & Vis Sci, 1716 Univ Blvd, Birmingham, AL 35294 USA
[3] NEI, NIH, 10 Ctr Dr, Bethesda, MD 20892 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
COHERENCE TOMOGRAPHY ANGIOGRAPHY; LASER SPECKLE FLOWGRAPHY; BLOOD-FLOW; VELOCITY; DYNAMICS; ABNORMALITIES; HEMODYNAMICS; ABERRATIONS; TECHNOLOGY; CONTRAST;
D O I
10.1364/BOE.9.003653
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The flow of erythrocytes in parafoveal capillaries was imaged in the living human eye with an adaptive optics near-confocal ophthalmoscope at a frame rate of 800 Hz with a low coherence near-infrared (NIR) light source. Spatiotemporal traces of the erythrocyte movement were extracted from consecutive images. Erythrocyte velocity was measured using custom software based on the Radon transform. The impact of imaging speed on velocity measurement was estimated using images of frame rates of 200, 400, and 800 Hz. The NIR light allowed for long imaging periods without visually stimulating the retina and disturbing the natural theological state. High speed near-confocal imaging enabled direct and accurate measurement of erythrocyte velocity, and revealed a distinctively cardiac-dependent pulsatile velocity waveform of the erythrocyte flow in retinal capillaries, disclosed the impact of the leukocytes on erythrocyte motion, and provided new metrics for precise assessment of erythrocyte movement. The approach may facilitate new investigations on the pathophysiology of retinal microcirculation with applications for ocular and systemic diseases. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3653 / 3677
页数:25
相关论文
共 91 条
[11]  
Bennun J, 1996, INVEST OPHTH VIS SCI, V37, P1854
[12]   Retinal abnormalities in early Alzheimer's disease [J].
Berisha, Fatmire ;
Feke, Gilbert T. ;
Trempe, Clement L. ;
McMeel, J. Wallace ;
Schepens, Charles L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (05) :2285-2289
[13]   A literature review and novel theoretical approach on the optical properties of whole blood [J].
Bosschaart, Nienke ;
Edelman, Gerda J. ;
Aalders, Maurice C. G. ;
van Leeuwen, Ton G. ;
Faber, Dirk J. .
LASERS IN MEDICAL SCIENCE, 2014, 29 (02) :453-479
[14]   Retinal Blood Flow Velocity in Patients with Age-Related Macular Degeneration [J].
Burgansky-Eliash, Zvia ;
Barash, Hila ;
Nelson, Darin ;
Grinvald, Amiram ;
Sorkin, Alina ;
Loewenstein, Anat ;
Barak, Adiel .
CURRENT EYE RESEARCH, 2014, 39 (03) :304-311
[15]   Computer algorithms for the automated measurement of retinal arteriolar diameters [J].
Chapman, N ;
Witt, N ;
Gao, X ;
Bharath, AA ;
Stanton, AV ;
Thom, SA ;
Hughes, AD .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) :74-79
[16]   Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT [J].
Choi, WooJhon ;
Baumann, Bernhard ;
Liu, Jonathan J. ;
Clermont, Allen C. ;
Feener, Edward P. ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05) :1047-1061
[17]   The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope [J].
Chui, Toco Y. P. ;
VanNasdale, Dean A. ;
Burns, Stephen A. .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (10) :2537-2549
[18]   Absolute Retinal Blood Flow Measurement With a Dual-Beam Doppler Optical Coherence Tomography [J].
Dai, Cuixia ;
Liu, Xiaojing ;
Zhang, Hao F. ;
Puliafito, Carmen A. ;
Jiao, Shuliang .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) :7998-8003
[19]   Rapid high resolution imaging with a dual-channel scanning technique [J].
de Castro, Alberto ;
Huang, Gang ;
Sawides, Lucie ;
Luo, Ting ;
Burns, Stephen A. .
OPTICS LETTERS, 2016, 41 (08) :1881-1884
[20]   Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices [J].
Delori, Francois C. ;
Webb, Robert H. ;
Sliney, David H. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1250-1265