Noninvasive in vivo characterization of erythrocyte motion in human retinal capillaries using high-speed adaptive optics near-confocal imaging

被引:55
作者
Gu, Boyu [1 ]
Wang, Xiaolin [1 ]
Twa, Michael D. [2 ]
Tam, Johnny [3 ]
Girkin, Christopher A. [1 ]
Zhang, Yuhua [1 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Visual Sci, 1670 Univ Blvd, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Sch Optometry, Dept Optometry & Vis Sci, 1716 Univ Blvd, Birmingham, AL 35294 USA
[3] NEI, NIH, 10 Ctr Dr, Bethesda, MD 20892 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 08期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
COHERENCE TOMOGRAPHY ANGIOGRAPHY; LASER SPECKLE FLOWGRAPHY; BLOOD-FLOW; VELOCITY; DYNAMICS; ABNORMALITIES; HEMODYNAMICS; ABERRATIONS; TECHNOLOGY; CONTRAST;
D O I
10.1364/BOE.9.003653
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The flow of erythrocytes in parafoveal capillaries was imaged in the living human eye with an adaptive optics near-confocal ophthalmoscope at a frame rate of 800 Hz with a low coherence near-infrared (NIR) light source. Spatiotemporal traces of the erythrocyte movement were extracted from consecutive images. Erythrocyte velocity was measured using custom software based on the Radon transform. The impact of imaging speed on velocity measurement was estimated using images of frame rates of 200, 400, and 800 Hz. The NIR light allowed for long imaging periods without visually stimulating the retina and disturbing the natural theological state. High speed near-confocal imaging enabled direct and accurate measurement of erythrocyte velocity, and revealed a distinctively cardiac-dependent pulsatile velocity waveform of the erythrocyte flow in retinal capillaries, disclosed the impact of the leukocytes on erythrocyte motion, and provided new metrics for precise assessment of erythrocyte movement. The approach may facilitate new investigations on the pathophysiology of retinal microcirculation with applications for ocular and systemic diseases. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3653 / 3677
页数:25
相关论文
共 91 条
  • [11] Bennun J, 1996, INVEST OPHTH VIS SCI, V37, P1854
  • [12] Retinal abnormalities in early Alzheimer's disease
    Berisha, Fatmire
    Feke, Gilbert T.
    Trempe, Clement L.
    McMeel, J. Wallace
    Schepens, Charles L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (05) : 2285 - 2289
  • [13] A literature review and novel theoretical approach on the optical properties of whole blood
    Bosschaart, Nienke
    Edelman, Gerda J.
    Aalders, Maurice C. G.
    van Leeuwen, Ton G.
    Faber, Dirk J.
    [J]. LASERS IN MEDICAL SCIENCE, 2014, 29 (02) : 453 - 479
  • [14] Retinal Blood Flow Velocity in Patients with Age-Related Macular Degeneration
    Burgansky-Eliash, Zvia
    Barash, Hila
    Nelson, Darin
    Grinvald, Amiram
    Sorkin, Alina
    Loewenstein, Anat
    Barak, Adiel
    [J]. CURRENT EYE RESEARCH, 2014, 39 (03) : 304 - 311
  • [15] Computer algorithms for the automated measurement of retinal arteriolar diameters
    Chapman, N
    Witt, N
    Gao, X
    Bharath, AA
    Stanton, AV
    Thom, SA
    Hughes, AD
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) : 74 - 79
  • [16] Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT
    Choi, WooJhon
    Baumann, Bernhard
    Liu, Jonathan J.
    Clermont, Allen C.
    Feener, Edward P.
    Duker, Jay S.
    Fujimoto, James G.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05): : 1047 - 1061
  • [17] The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope
    Chui, Toco Y. P.
    VanNasdale, Dean A.
    Burns, Stephen A.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2012, 3 (10): : 2537 - 2549
  • [18] Absolute Retinal Blood Flow Measurement With a Dual-Beam Doppler Optical Coherence Tomography
    Dai, Cuixia
    Liu, Xiaojing
    Zhang, Hao F.
    Puliafito, Carmen A.
    Jiao, Shuliang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) : 7998 - 8003
  • [19] Rapid high resolution imaging with a dual-channel scanning technique
    de Castro, Alberto
    Huang, Gang
    Sawides, Lucie
    Luo, Ting
    Burns, Stephen A.
    [J]. OPTICS LETTERS, 2016, 41 (08) : 1881 - 1884
  • [20] Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
    Delori, Francois C.
    Webb, Robert H.
    Sliney, David H.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) : 1250 - 1265