Comparison of impedance cardiography and dye dilution method for measuring cardiac output

被引:17
|
作者
Spiering, W [1 ]
van Es, PN [1 ]
de Leeuw, PW [1 ]
机构
[1] Univ Hosp Maastricht, Dept Internal Med, NL-6202 AZ Maastricht, Netherlands
关键词
cardiac output; impedance cardiography; dye dilution;
D O I
10.1136/hrt.79.5.437
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the degree of agreement between impedance cardiography, using the NCCOM3-R7 device, and the gold standard-the dye dilution method-both under basal conditions and after stimulation of cardiac output. Patients-35 paired measurements in five healthy male volunteers. interventions-To obtain higher levels of cardiac output, cardiac performance was stimulated with a dopamine infusion. Results-In 35 paired measurements, the mean of all the impedance values was higher than that of the dye dilution values, at 10.2 v 7.4 l/min (p < 0.0001). The mean discrepancy between the two methods was 3.3 l/min, and the mean bias -2.9 l/min, with limits of agreement of -9.0 and 3.2 l/min. A change in cardiac output could not adequately be predicted by the NCCOM3-R7. In 20 of 25 measurements obtained during continuous intravenous dopamine infusions there was a rise in dye dilution cardiac output (range 0.2 to 5.9 l/min). Neither the magnitude nor the direction of the change in dye dilution values corresponded with the change measured by impedance cardiography. The mean discrepancy here between the two methods was 1.8 l/min, and the mean bias -0.8 l/min, with limits of agreement of -4.9 and 3.3 l/min. Conclusions-In healthy volunteers, impedance cardiography with NCCOM3-R7 is inadequate for assessing cardiac output when compared with the dye dilution method.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 50 条
  • [41] Diagnostic capabilities of impedance cardiography method in pulmonary hypertension
    Sadauskas, Saulius
    Naudziunas, Albinas
    Unikauskas, Alvydas
    Gargasas, Liudas
    Ruseckas, Rimtautas
    Jurkoniene, Ruta
    MEDICINA-LITHUANIA, 2010, 46 (10): : 669 - 678
  • [42] Evaluation of a method utilizing PhysioFlow®, a novel signal morphology-based form of impedance cardiography, to measure cardiac output in the conscious beagle
    Payseur, Jason D.
    Rigney, John J.
    Turner, Sandra L.
    Wu, XueJun
    Murphy, Dennis J.
    Rossman, Eric I.
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2016, 81 : 115 - 119
  • [43] Correlation of continuous cardiac output measured by a pulmonary artery catheter versus impedance cardiography in ventilated patients
    D Ziegler
    M Tellez
    D Hess
    T Dipprey
    Critical Care, 8 (Suppl 1):
  • [44] Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography
    Osbak, Philip S.
    Henriksen, Jens H.
    Kofoed, Klaus F.
    Jensen, Gorm B.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2011, 71 (04) : 304 - 313
  • [45] Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    T. Kööbi
    S. Kaukinen
    T. Ahola
    V. M. H. Turjanmaa
    Intensive Care Medicine, 1997, 23 : 1132 - 1137
  • [46] Design of a Device for Determining Stroke Volume by the Impedance Cardiography Method
    Shlyakhotka, Anna V.
    Lyakhova, Ekaterina K.
    Sutyagina, Anastasiya D.
    PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 1225 - 1226
  • [47] Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    Koobi, T
    Kaukinen, S
    Ahola, T
    Turjanmaa, VMH
    INTENSIVE CARE MEDICINE, 1997, 23 (11) : 1132 - 1137
  • [48] Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
    Pittman, J
    Bar-Yosef, S
    SumPing, J
    Sherwood, M
    Mark, J
    CRITICAL CARE MEDICINE, 2005, 33 (09) : 2015 - 2021
  • [49] Measurement of Cardiac Output and Blood Volume During Hemodialysis with Fluorescent Dye Dilution Technique
    Jean Michel I. Maarek
    Eduardo H. Rubinstein
    Yumei Guo
    Christianne J. Lane
    Vito M. Campese
    Daniel P. Holschneider
    Annals of Biomedical Engineering, 2017, 45 : 580 - 591
  • [50] Measurement of Cardiac Output and Blood Volume During Hemodialysis with Fluorescent Dye Dilution Technique
    Maarek, Jean Michel I.
    Rubinstein, Eduardo H.
    Guo, Yumei
    Lane, Christianne J.
    Campese, Vito M.
    Holschneider, Daniel P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (03) : 580 - 591