Comparison of impedance cardiography and dye dilution method for measuring cardiac output

被引:17
|
作者
Spiering, W [1 ]
van Es, PN [1 ]
de Leeuw, PW [1 ]
机构
[1] Univ Hosp Maastricht, Dept Internal Med, NL-6202 AZ Maastricht, Netherlands
关键词
cardiac output; impedance cardiography; dye dilution;
D O I
10.1136/hrt.79.5.437
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the degree of agreement between impedance cardiography, using the NCCOM3-R7 device, and the gold standard-the dye dilution method-both under basal conditions and after stimulation of cardiac output. Patients-35 paired measurements in five healthy male volunteers. interventions-To obtain higher levels of cardiac output, cardiac performance was stimulated with a dopamine infusion. Results-In 35 paired measurements, the mean of all the impedance values was higher than that of the dye dilution values, at 10.2 v 7.4 l/min (p < 0.0001). The mean discrepancy between the two methods was 3.3 l/min, and the mean bias -2.9 l/min, with limits of agreement of -9.0 and 3.2 l/min. A change in cardiac output could not adequately be predicted by the NCCOM3-R7. In 20 of 25 measurements obtained during continuous intravenous dopamine infusions there was a rise in dye dilution cardiac output (range 0.2 to 5.9 l/min). Neither the magnitude nor the direction of the change in dye dilution values corresponded with the change measured by impedance cardiography. The mean discrepancy here between the two methods was 1.8 l/min, and the mean bias -0.8 l/min, with limits of agreement of -4.9 and 3.3 l/min. Conclusions-In healthy volunteers, impedance cardiography with NCCOM3-R7 is inadequate for assessing cardiac output when compared with the dye dilution method.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 50 条
  • [21] Latest Advances in Cardiac Output Monitoring from High-Definition Impedance Cardiography
    Jean J. Bour
    Current Anesthesiology Reports, 2018, 8 (2) : 238 - 244
  • [22] IMPEDANCE CARDIOGRAPHY FOR CARDIAC-OUTPUT MEASUREMENT - AN EVALUATION OF ACCURACY AND LIMITATIONS
    WHITE, SW
    QUAIL, AW
    DELEEUW, PW
    TRAUGOTT, FM
    BROWN, WJ
    PORGES, WL
    COTTEE, DB
    EUROPEAN HEART JOURNAL, 1990, 11 : 79 - 92
  • [23] RELIABILITY OF IMPEDANCE CARDIOGRAPHY IN MEASURING CENTRAL HEMODYNAMICS
    MEHLSEN, J
    BONDE, J
    STADEAGER, C
    REHLING, M
    TANGO, M
    TRAPJENSEN, J
    CLINICAL PHYSIOLOGY, 1991, 11 (06): : 579 - 588
  • [24] A comparison of the Finapres and impedance cardiography for non-invasive estimation of cardiac output during mental stress
    Wilhelm, FH
    Mauss, IB
    Pastuszek, DS
    Gross, JJ
    PSYCHOPHYSIOLOGY, 2003, 40 : S91 - S91
  • [25] A NEW METHOD OF MEASURING CARDIAC-OUTPUT IN MAN USING LITHIUM DILUTION
    LINTON, RAF
    BAND, DM
    HAIRE, KM
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (02) : 262 - 266
  • [26] Impedance cardiography in cardiac pacing
    Peczalski, K.
    Wojciechowski, D.
    Dunajski, Z.
    Palko, T.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 582 - +
  • [27] Cardiac Output Determination From Endotracheally Measured Impedance Cardiography: Clinical Evaluation of Endotracheal Cardiac Output Monitor
    Maus, Timothy M.
    Reber, Bradley
    Banks, Dalia A.
    Berry, Ashley
    Guerrero, Emmanuel
    Manecke, Gerard R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (05) : 770 - 775
  • [28] Comparison of continuous cardiac output monitoring derived from regional impedance cardiography with continuous thermodilution technique in cardiac surgical patients
    Bhavya, G.
    Nagaraja, P. S.
    Singh, Naveen G.
    Ragavendran, S.
    Sathish, N.
    Manjunath, N.
    Kumar, K. Ashok
    Nayak, Vinayak B.
    ANNALS OF CARDIAC ANAESTHESIA, 2020, 23 (02) : 189 - 192
  • [29] Non-invasive assessment of cardiac output during exercise in chronic obstructive pulmonary disease: comparison of the CO2-rebreathing method and electrical impedance cardiography
    Bogaard, HJ
    Hamersma, WBGJ
    Horsch, JLMI
    Woltjer, HH
    Postmus, PE
    deVries, PMJM
    PHYSIOLOGICAL MEASUREMENT, 1997, 18 (04) : 327 - 338
  • [30] Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography
    Goedhart, AD
    Kupper, N
    Willemsen, G
    Boomsma, DI
    de Geus, EJC
    BIOLOGICAL PSYCHOLOGY, 2006, 72 (01) : 110 - 117