Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT

被引:3
|
作者
Jia, Yongjun [1 ,2 ]
Ji, Xing [3 ]
He, Taiping [2 ]
Yu, Yong [2 ]
Yu, Nan [2 ]
Duan, Haifeng [2 ]
Guo, Youmin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Yanta Western Rd, Xian 710061, Shaanxi, Peoples R China
[2] Shaanxi Chinese Med Univ, Affiliated Hosp, Dept Radiol, Xianyang 712000, Peoples R China
[3] Yanan Univ, Affiliated Hosp, Dept Radiol, Yanan 716000, Peoples R China
关键词
Model-based iterative reconstruction; computer-aided detection; tomography; X-ray computed; radiation dosage; COMPUTER-AIDED DETECTION; ABDOMINAL CT; IDENTIFICATION; REDUCTION; WALL;
D O I
10.1016/j.acra.2018.03.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We aimed to evaluate a new model-based iterative reconstruction (MBIRn) algorithm either with spatial resolution and noise reduction balance (MBIRSTND) or spatial resolution preference (MBIRRP20) for quantitative analysis of airway in low-dose chest computed tomography (CT) with a computer-aided detection (CAD) software, in comparison to adaptive statistical iterative reconstruction (ASIR) in routine-dose CT. Methods: Thirty patients who underwent both the routine-dose (noise index [NI] = 14 HU) and low-dose (at 30% level with NI = 28 HU) CT examination for pulmonary disease were included. Image acquisition was performed with 120 kVp tube voltage and automatic tube current modulation. Routine-dose scans were reconstructed with ASIR, whereas low-dose scans were reconstructed with ASIR, MBIRSTND, and MBIRRP20. Airway dimensions of the right middle lobe bronchus from the four reconstructions were measured using CAD software. Two radiologists used a semiquantitative 5 scoring criteria (-2, inferior to; +2, superior to; -1 slightly inferior to; +1, slightly superior to; and 0, equal to ASIR in routine-dose CT) to rate the subjective image quality of MBIRSTND\ and MBIRRP20 of airway trees. The paired t test and Wilcoxon signed-rank test were used for statistical comparison. Results: The low-dose CT provided 70.76% dose reduction compared to the routine-dose CT (0.88 +/- 0.83 mSv vs 3.01 +/- 1.89 mSv). MBIRSTND and MBIRRP20 with low-dose CT provided longer bronchial length measurements and were better in measurement variability and continuity and completeness of bronchial walls than ASIR in routine-dose CT (P < .05). MBIRSTND was better for subjective noise and MBIRRP20 for showing distal branches. Conclusions: MBIRSTND and MBIRRP20 algorithms provide better airway quantification at 30% of the radiation dose, compared to ASIR at routine-dose CT.
引用
收藏
页码:1526 / 1532
页数:7
相关论文
共 50 条
  • [1] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [2] Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients
    Sagara, Yoshiko
    Hara, Amy K.
    Pavlicek, William
    Silva, Alvin C.
    Paden, Robert G.
    Wu, Qing
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 713 - 719
  • [3] Model-Based Iterative Reconstruction Versus Adaptive Statistical Iterative Reconstruction in Low-Dose Abdominal CT for Urolithiasis
    Botsikas, Diomidis
    Stefanelli, Salvatore
    Boudabbous, Sana
    Toso, Seema
    Becker, Christoph D.
    Montet, Xavier
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 336 - 340
  • [4] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [5] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1613 - 1623
  • [6] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13
  • [7] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Nagasawa, Naoki
    Murashima, Shuichi
    Sakuma, Hajime
    BMC MEDICAL IMAGING, 2013, 13
  • [8] Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection
    Lee, Nam Kyung
    Kim, Suk
    Hong, Seung BaeK
    Kim, Tae Un
    Ryu, Hwaseong
    Lee, Ji Won
    Kim, Jin You
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 659 - 666
  • [9] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [10] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Nagata, Koichi
    Fujiwara, Masanori
    Kanazawa, Hidenori
    Mogi, Tomohiro
    Iida, Nao
    Mitsushima, Toru
    Lefor, Alan T.
    Sugimoto, Hideharu
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 221 - 229