A novel image-domain-based cone-beam computed tomography enhancement algorithm

被引:11
|
作者
Li, Xiang [1 ]
Li, Tianfang [1 ]
Yang, Yong [1 ]
Heron, Dwight E. [1 ]
Huq, M. Saiful [1 ]
机构
[1] Univ Pittsburgh, Inst Canc, Dept Radiat Oncol, Pittsburgh, PA 15232 USA
关键词
X-RAY SCATTER; MAGNETIC-RESONANCE IMAGES; RADIATION-THERAPY; CT; SEGMENTATION; QUALITY; SIMULATION; REDUCTION; NOISE;
D O I
10.1088/0031-9155/56/9/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kilo-voltage (kV) cone-beam computed tomography (CBCT) plays an important role in image-guided radiotherapy. However, due to a large cone-beam angle, scatter effects significantly degrade the CBCT image quality and limit its clinical application. The goal of this study is to develop an image enhancement algorithm to reduce the low-frequency CBCT image artifacts, which are also called the bias field. The proposed algorithm is based on the hypothesis that image intensities of different types of materials in CBCT images are approximately globally uniform (in other words, a piecewise property). A maximum a posteriori probability framework was developed to estimate the bias field contribution from a given CBCT image. The performance of the proposed CBCT image enhancement method was tested using phantoms and clinical CBCT images. Compared to the original CBCT images, the corrected images using the proposed method achieved a more uniform intensity distribution within each tissue type and significantly reduced cupping and shading artifacts. In a head and a pelvic case, the proposed method reduced the Hounsfield unit (HU) errors within the region of interest from 300 HU to less than 60 HU. In a chest case, the HU errors were reduced from 460 HU to less than 110 HU. The proposed CBCT image enhancement algorithm demonstrated a promising result by the reduction of the scatter-induced low-frequency image artifacts commonly encountered in kV CBCT imaging.
引用
收藏
页码:2755 / 2766
页数:12
相关论文
共 50 条
  • [21] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [22] Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
    Luo, Chen
    Liu, Qiao
    Gong, Shutao
    Yang, Chunlin
    Hu, Xiuhua
    Nie, Ke
    Niu, Tianye
    IEEE ACCESS, 2019, 7 : 1247 - 1259
  • [23] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) : 3S - 6S
  • [24] Prevalence of Artifacts in Cone-Beam Computed Tomography: A Retrospective Study
    Mahesh, K. P.
    Deshpande, Prasannasrinivas
    Viveka, S.
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (04) : 428 - 431
  • [25] Organ dose and radiogenic risk in dental cone-beam computed tomography examinations
    Almuqrin, Aljawhara H.
    Tamam, Nissren
    Abdelrazig, A.
    Elnour, A.
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2020, 176
  • [26] Scatter correction for cone-beam computed tomography using moving blocker strips: A preliminary study
    Wang, Jing
    Mao, Weihua
    Solberg, Timothy
    MEDICAL PHYSICS, 2010, 37 (11) : 5792 - 5800
  • [27] A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy
    Liu, Yimei
    Chen, Meining
    Fang, Jianlan
    Xiao, Liangjie
    Liu, Songran
    Li, Qiwen
    Qiu, Bo
    Huang, Runda
    Zhang, Jun
    Peng, Yinglin
    THORACIC CANCER, 2024, 15 (17) : 1333 - 1342
  • [28] Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality
    Moratin, Julius
    Berger, Moritz
    Ruckschloss, Thomas
    Metzger, Karl
    Berger, Hannah
    Gottsauner, Maximilian
    Engel, Michael
    Hoffmann, Jurgen
    Freudlsperger, Christian
    Ristow, Oliver
    IMAGING SCIENCE IN DENTISTRY, 2020, 50 (03) : 227 - 236
  • [29] Computed gray levels in multislice and cone-beam computed tomography
    Azeredo, Fabiane
    de Menezes, Luciane Macedo
    Enciso, Reyes
    Weissheimer, Andre
    de Oliveira, Rogerio Belle
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) : 147 - 155
  • [30] Accuracy of cone-beam computed tomography for syndesmosis injury diagnosis compared to conventional computed tomography
    Hamard, Marion
    Neroladaki, Angeliki
    Bagetakos, Ilias
    Dubois-Ferriere, Victor
    Montet, Xavier
    Boudabbous, Sana
    FOOT AND ANKLE SURGERY, 2020, 26 (04) : 265 - 272