A feasibility and load sensitivity analysis of photovoltaic water pumping system with battery and diesel generator

被引:32
作者
Muhsen, Dhiaa Halboot [1 ]
Khatib, Tamer [2 ]
Haider, Haider Tarish [1 ]
机构
[1] Univ Al Mustansiriyah, Dept Comp & Software Engn, Baghdad, Iraq
[2] An Najah Natl Univ, Dept Energy Engn & Environm, Nablus, Palestine
关键词
Feasibility; Loss of load probability; Battery; Photovoltaic water pumping system; Life cycle cost; RENEWABLE ENERGY; ANALYTICAL-MODEL; STANDALONE; OPTIMIZATION; ALGORITHM; STORAGE; PERFORMANCE; MANAGEMENT; DESIGN; AREAS;
D O I
10.1016/j.enconman.2017.06.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a feasibility and load sensitivity analysis is conducted for photovoltaic water pumping systems with storage device (battery) or diesel generator so as to obtain an optimal configuration that achieves a reliable system. The analysis is conducted based on techno-economic aspects, where the loss of load probability and life cycle cost are represented as technical and economic criteria, respectively. Various photovoltaic water pumping systems scenarios with initially full storage tank; battery and hybrid DG-PV energy source are proposed to analyze the feasibility of system. The result shows that the configuration of the PV array and the initial status of the storage tank are important variables to be considered. Moreover, the sensitivity of cost of unit for various PVPS components is studied. It is found that the cost of unit is more sensitive to the initial capital cost of photovoltaic array than other components. In this paper a standalone PV based pumping system with a PV array capacity of 2.4 kWp and a storage tank with a capacity of 80 m(3) was proposed an a optimum system. The system with the aforementioned configuration pumps an average hourly water volume of approximately 3.297 m(3) over one year with a unit of 0.05158 USD/m(3). Moreover, according to results, increasing the maximum capacity of water storage tank is technically and economically better than supporting a photovoltaic water pumping systems with another energy source or extra storage device. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:287 / 304
页数:18
相关论文
共 36 条
  • [1] Acakpovi A, 2012 IEEE 4 INT C, P65
  • [2] [Anonymous], ENERGY SUSTAIN DEV
  • [3] [Anonymous], ASME SOL 2002 INT SO
  • [4] Optimal renewable power generation systems for Busan metropolitan city in South Korea
    Baek, Seoin
    Park, Eunil
    Kim, Min-Gil
    Kwon, Sang Jib
    Kim, Ki Joon
    Ohm, Jay Y.
    del Pobil, Angel P.
    [J]. RENEWABLE ENERGY, 2016, 88 : 517 - 525
  • [5] Optimal sizing of photovoltaic pumping system with water tank storage using LPSP concept
    Bakelli, Yahia
    Arab, Amar Hadj
    Azoui, Boubekeur
    [J]. SOLAR ENERGY, 2011, 85 (02) : 288 - 294
  • [6] New sizing method of PV water pumping systems
    Bouzidi, Belkacem
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2013, 4 : 1 - 10
  • [7] The feasibility of renewable energy sources for pumping clean water in sub-Saharan Africa: A case study for Central Nigeria
    Cloutier, Michael
    Rowley, Paul
    [J]. RENEWABLE ENERGY, 2011, 36 (08) : 2220 - 2226
  • [8] Douglas J., 1986, FLUID MECH LONGMAN S
  • [9] Multi-objective design of PV-wind-diesel-hydrogen-battery systems
    Dufo-Lopez, Rodolfo
    Bernal-Agustin, Jose L.
    [J]. RENEWABLE ENERGY, 2008, 33 (12) : 2559 - 2572
  • [10] Multi-objective optimization minimizing cost and life cycle emissions of stand-alone PV-wind-diesel systems with batteries storage
    Dufo-Lopez, Rodolfo
    Bernal-Agustin, Jose L.
    Yusta-Loyo, Jose M.
    Dominguez-Navarro, Jose A.
    Ramirez-Rosado, Ignacio J.
    Lujano, Juan
    Aso, Ismael
    [J]. APPLIED ENERGY, 2011, 88 (11) : 4033 - 4041