A Novel I-SFCL Concept for Application in Flexible DC Grid Considering the Operation Stability

被引:5
作者
He, Jiawei [1 ]
Li, Bin [1 ]
Li, Chao [1 ]
Jia, Hanru [1 ]
Li, Ye [1 ]
Coombs, Tim [2 ]
机构
[1] Tianjin Univ, Key Lab Smart Grid, Minist Educ, Tianjin 300072, Peoples R China
[2] Univ Cambridge, Dept Engn, Elect Engn Div, Cambridge CB3 0FA, England
基金
中国国家自然科学基金;
关键词
Flexible dc grid; dc SFCL; transient response ability; operation stability;
D O I
10.1109/TASC.2021.3101787
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
DC fault current limitation is the key technique to improve the reliability and security of flexible dc grid operation. But the traditional dc fault current limiting method, which directly installs inductor in dc grid, will seriously deteriorate transient response ability and operation stability of the dc grid. In this paper, a simple I-SFCL topology is proposed. According to the theoretical analysis, the I-SFCL has similar ability of limiting dc fault current compared with the method directly installing dc inductor. And it can effectively eliminate negative effect of dc inductor on system transient response ability and operation stability. Finally, the simulation cases based on PSCAD/EMTDC proves the correctness of theoretical analysis and superiority of the proposed I-SFCL.
引用
收藏
页数:5
相关论文
共 12 条
[1]   Study on Coordination of Resistive SFCLs and Hybrid-Type Circuit Breakers to Protect a HVDC System With LCC and VSC Stations [J].
Chen, Lei ;
Li, Guocheng ;
He, Huiwen ;
Chen, Hongkun ;
Li, Yanhong ;
Ding, Meng ;
Zhang, Xuyang ;
Xu, Ying ;
Ren, Li ;
Tang, Yuejin .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)
[2]   Transient Characteristics Under Ground and Short-Circuit Faults in a ±500 kV MMC-Based HVDC System With Hybrid DC Circuit Breakers [J].
Han, Xue ;
Sima, Wenxia ;
Yang, Ming ;
Li, Licheng ;
Yuan, Tao ;
Si, Yan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (03) :1378-1387
[3]   Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker [J].
Hassanpoor, Arman ;
Haefner, Juergen ;
Jacobson, Bjoern .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (10) :5393-5400
[4]   Analysis of the fault current limiting requirement and design of the bridge-type FCL in the multi-terminal DC grid [J].
He, Jiawei ;
Li, Bin ;
Li, Ye .
IET POWER ELECTRONICS, 2018, 11 (06) :968-976
[5]   A Novel Single-Ended Transient-Voltage-Based Protection Strategy for Flexible DC Grid [J].
Li, Bin ;
Li, Ye ;
He, Jiawei ;
Wen, Weijie .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (05) :1925-1937
[6]   Studies on the Application of R-SFCL in the VSC-Based DC Distribution System [J].
Li, Bin ;
He, Jiawei .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
[7]   Research on the Parameter Matching Between Active SI-SFCL and DC Circuit Breaker in DC systems [J].
Li, Botong ;
Jing, Fangjie ;
Li, Bin ;
Wen, Weijie .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
[8]   Harmonic Instability in MMC-HVDC Converters Resulting From Internal Dynamics [J].
Li, Tan ;
Gole, Aniruddha M. ;
Zhao, Chengyong .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) :1738-1747
[9]   The application of active superconducting DC fault current limiter in hybrid AC/DC power supply systems [J].
Shi, Jing ;
Tang, Yuejin ;
Chen, Lei ;
Wang, Jin ;
Ren, Li ;
Li, Jingdong ;
Li, Liang ;
Peng, Tao ;
Cheng, Shijie .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) :672-675
[10]  
Song M, SUPERCOND SCI TECHNO, V34