Smart Shoe-Assisted Evaluation of Using a Single Trunk/Pocket-Worn Accelerometer to Detect Gait Phases

被引:22
作者
Avvenuti, Marco [1 ]
Carbonaro, Nicola [1 ,2 ]
Cimino, Mario G. C. A. [1 ]
Cola, Guglielmo [1 ]
Tognetti, Alessandro [1 ,2 ]
Vaglini, Gigliola [1 ]
机构
[1] Univ Pisa, Dipartimento Ingn Informaz, Largo Lazzarino 1, I-56122 Pisa, Italy
[2] Univ Pisa, Res Ctr E Piaggio, Largo Lucio Lazzarino 1, I-56122 Pisa, Italy
关键词
accelerometer; foot contact detection; gait analysis; gait phase detection; pocket-worn; smart shoe; wearable sensor; EVENT DETECTION; FALL-RISK; PARAMETERS; RELIABILITY; FRAILTY; MODELS;
D O I
10.3390/s18113811
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Wearable sensors may enable the continuous monitoring of gait out of the clinic without requiring supervised tests and costly equipment. This paper investigates the use of a single wearable accelerometer to detect foot contact times and estimate temporal gait parameters (stride time, swing and stance duration). The experiments considered two possible body positions for the accelerometer: over the lower trunk and inside a trouser pocket. The latter approach could be implemented using a common smartphone. Notably, during the experiments, the ground truth was obtained by using a pair of sensorized shoes. Unlike ambient sensors and camera-based systems, sensorized shoes enable the evaluation of body-worn sensors even during longer walks. Experiments showed that both trunk and pocket positions achieved promising results in estimating gait parameters, with a mean absolute error below 50 ms.
引用
收藏
页数:13
相关论文
共 37 条
[1]   Sleep behavior assessment via smartwatch and stigmergic receptive fields [J].
Alfeo, Antonio L. ;
Barsocchi, Paolo ;
Cimino, Mario G. C. A. ;
La Rosa, Davide ;
Palumbo, Filippo ;
Vaglini, Gigliola .
PERSONAL AND UBIQUITOUS COMPUTING, 2018, 22 (02) :227-243
[2]   Measuring Physical Activity of Older Adults via Smartwatch and Stigmergic Receptive Fields [J].
Alfeo, Antonio L. ;
Cimino, Mario G. C. A. ;
Vaglini, Gigliola .
ICPRAM: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION APPLICATIONS AND METHODS, 2017, :724-730
[3]   Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes [J].
Aminian, K ;
Najafi, B ;
Büla, C ;
Leyvraz, PF ;
Robert, P .
JOURNAL OF BIOMECHANICS, 2002, 35 (05) :689-699
[4]  
[Anonymous], 2015, P 2015 IEEE 12 INT C, DOI DOI 10.1109/BSN.2015.7299423
[5]   Using gait symmetry to virtually align a triaxial accelerometer during running and walking [J].
Avvenuti, M. ;
Casella, A. ;
Cesarini, D. .
ELECTRONICS LETTERS, 2013, 49 (02) :120-U8
[6]  
AVVENUTI M, 2018, PROCEEDINGS OF THE 7, V247, P250, DOI DOI 10.1007/978-3-319-98551-0_29
[7]   Estimation of spatial-temporal gait parameters in level walking based on a single accelerometer: Validation on normal subjects by standard gait analysis [J].
Bugane, F. ;
Benedetti, M. G. ;
Casadio, G. ;
Attala, S. ;
Biagi, F. ;
Manca, M. ;
Leardini, A. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) :129-137
[8]   Assessment of a Smart Sensing Shoe for Gait Phase Detection in Level Walking [J].
Carbonaro, Nicola ;
Lorussi, Federico ;
Tognetti, Alessandro .
ELECTRONICS, 2016, 5 (04)
[9]   Real-Time Identification Using Gait Pattern Analysis on a Standalone Wearable Accelerometer [J].
Cola, Guglielmo ;
Avvenuti, Marco ;
Vecchio, Alessio .
COMPUTER JOURNAL, 2017, 60 (08) :1173-1186
[10]   Improving the performance of fall detection systems through walk recognition [J].
Cola, Guglielmo ;
Vecchio, Alessio ;
Avvenuti, Marco .
JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2014, 5 (06) :843-855