Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T

被引:244
作者
Yokoo, Takeshi [1 ]
Shiehmorteza, Masoud [1 ]
Hamilton, Gavin [1 ]
Wolfson, Tanya [5 ]
Schroeder, Michael E. [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Gamst, Anthony C. [5 ]
Kono, Yuko [2 ]
Kuo, Alexander [2 ]
Patton, Heather M. [2 ]
Horgan, Santiago [4 ]
Lavine, Joel E. [3 ]
Schwimmer, Jeffrey B. [3 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Dept Internal Med, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Pediat, San Diego, CA 92103 USA
[4] Univ Calif San Diego, Dept Surg, San Diego, CA 92103 USA
[5] Univ Calif San Diego, Div Biostat & Informat, San Diego, CA 92103 USA
基金
美国国家卫生研究院;
关键词
MAGNETIC-RESONANCE-SPECTROSCOPY; LIVER-DISEASE; GRADIENT-ECHO; NONALCOHOLIC STEATOHEPATITIS; METABOLIC SYNDROME; FLIP-ANGLE; FOLLOW-UP; QUANTIFICATION; STEATOSIS; RISK;
D O I
10.1148/radiol.10100659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the accuracy of several magnetic resonance (MR) imaging-based methods for hepatic proton-density fat fraction (FF) estimation at 3.0 T, with spectroscopy as the reference technique. Materials and Methods: This prospective study was institutional review board approved and HIPAA compliant. Informed consent was obtained. One hundred sixty-three subjects (39 with known hepatic steatosis, 110 with steatosis risk factors, 14 without risk factors) underwent proton MR spectroscopy and non-T1-weighted gradient-echo MR imaging of the liver. At spectroscopy, the reference FF was determined from frequency-selective measurements of fat and water proton densities. At imaging, FF was calculated by using two-, three-, or six-echo methods, with single-frequency and multifrequency fat signal modeling. The three-and six-echo methods corrected for T2*; the two-echo methods did not. For each imaging method, the fat estimation accuracy was assessed by using linear regression between the imaging FF and spectroscopic FF. Binary classification accuracy of imaging was assessed at four reference spectroscopic thresholds (0.04, 0.06, 0.08, and 0.10 FF). Results: Regression intercept of two-, three-, and six-echo methods were -0.0211, 0.0087, and -0.0062 (P<.001 for all three) without multifrequency modeling and -0.0237 (P<.001), 0.0022, and -0.0007 with multifrequency modeling, respectively. Regression slope of two-, three-, and six-echo methods were 0.8522, 0.8528, and 0.7544 (P<.001 for all three) without multifrequency modeling and 0.9994, 0.9775, and 0.9821 with multifrequency modeling, respectively. Significant deviation of intercept and slope from 0 and 1, respectively, indicated systematic error. Classification accuracy was 82.2%-90.1%, 93.9%-96.3%, and 83.4%-89.6% for two-, three-, and six-echo methods without multifrequency modeling and 88.3%-92.0%, 95.1%-96.3%, and 94.5%-96.3% with multifrequency modeling, respectively, depending on the FF threshold. T2* -corrected (three-and six-echo) multifrequency imaging methods had the overall highest FF estimation and classification accuracy. Among methods without multifrequency modeling, the T2* -corrected three-echo method had the highest accuracy. Conclusion: Non-T1-weighted MR imaging with T2* correction and multifrequency modeling helps accurately estimate hepatic proton-density FF at 3.0 T. (C)RSNA, 2011
引用
收藏
页码:749 / 759
页数:11
相关论文
共 62 条
  • [11] Suspected Nonalcoholic Fatty Liver Disease and Mortality Risk in a Population-Based Cohort Study
    Dunn, Winston
    Xu, Ronghui
    Wingard, Deborah L.
    Rogers, Christopher
    Angulo, Paul
    Younossi, Zobair M.
    Schwimmer, Jeffrey B.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (09) : 2263 - 2271
  • [12] EFRON B, 1987, J AM STAT ASSOC, V82, P171, DOI 10.2307/2289144
  • [13] Long-term follow-up of patients with NAFLD and elevated liver enzymes
    Ekstedt, Mattias
    Franzen, Lennart E.
    Mathiesen, Ulrik L.
    Thorelius, Lars
    Holmqvist, Marika
    Bodemar, Goran
    Kechagias, Stergios
    [J]. HEPATOLOGY, 2006, 44 (04) : 865 - 873
  • [14] Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver
    Fishbein, MH
    Stevens, WR
    [J]. PEDIATRIC RADIOLOGY, 2001, 31 (11) : 806 - 809
  • [15] Forgione A, 2007, Minerva Gastroenterol Dietol, V53, P83
  • [16] Quantification of Liver Fat Content: Comparison of Triple-Echo Chemical Shift Gradient-Echo Imaging and in Vivo Proton MR Spectroscopy
    Guiu, Boris
    Petit, Jean-Michel
    Loffroy, Romaric
    Salem, Douraied Ben
    Aho, Serge
    Masson, David
    Hillon, Patrick
    Krause, Denis
    Cercueil, Jean-Pierre
    [J]. RADIOLOGY, 2009, 250 (01) : 95 - 102
  • [17] HAMILTON G, 2007, RAD SOC N AM SCI ASS, P548
  • [18] HAMILTON G, 2009, P 17 M INT SOC MAGN, P2149
  • [19] Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification
    Hamilton, Gavin
    Middleton, Michael S.
    Bydder, Mark
    Yokoo, Takeshi
    Schwimmer, Jeffrey B.
    Kono, Yuko
    Patton, Heather M.
    Lavine, Joel E.
    Sirlin, Claude B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 145 - 152
  • [20] Modest weight loss and physical activity in overweight patients with chronic liver disease results in sustained improvements in alanine aminotransferase, fasting insulin, and quality of life
    Hickman, IJ
    Jonsson, JR
    Prins, JB
    Ash, S
    Purdie, DM
    Clouston, AD
    Powell, EE
    [J]. GUT, 2004, 53 (03) : 413 - 419