Experimental analysis of a two-material active magnetic regenerator

被引:38
作者
Arnold, D. S. [1 ]
Tura, A. [1 ]
Rowe, A. [1 ]
机构
[1] Univ Victoria, Inst Integrated Energy Syst, Dept Mech Engn, Victoria, BC V8W 3P6, Canada
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2011年 / 34卷 / 01期
基金
加拿大自然科学与工程研究理事会;
关键词
Magnetic refrigeration; COP-exergy; Performance; Gadolinium-cost; PERFORMANCE; REFRIGERATOR; DESIGN;
D O I
10.1016/j.ijrefrig.2010.08.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental results of an active magnetic regenerator (AMR) composed of two equal volumes of gadolinium and Gd0.85Er0.15 using 2 T and 5 T are reported. Drive forces and system losses are measured as a function of thermal load and magnetic field. Metrics for coefficient of performance and efficiency are defined and used to distinguish between regenerator and device performance. Results suggest the largest temperature spans are expected to occur when each material is operating with its average temperature near their Curie temperatures. Force measurements indicate that mechanical losses and pumping power are the most significant contributions to network while the net magnetic work is too small to be resolved. COP values for the magnetic cycle are as high as 2.4 while efficiencies are all less than 0.15. A maximum exergetic cooling of 1.94 W is estimated with a corresponding specific exergetic cooling power of 23 W T-1L-1. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:178 / 191
页数:14
相关论文
共 11 条
  • [1] [Anonymous], P 3 INT C MAGN REFR
  • [2] Recent developments in room temperature active magnetic regenerative refrigeration
    Engelbrecht, Kurt L.
    Nellis, Greg F.
    Klein, Sanford A.
    Zimm, Carl B.
    [J]. HVAC&R RESEARCH, 2007, 13 (04): : 525 - 542
  • [3] Predicting the performance of an active magnetic regenerator refrigerator used for space cooling and refrigeration
    Engelbrecht, Kurt L.
    Nellis, Greg F.
    Klein, Sanford A.
    [J]. HVAC&R RESEARCH, 2006, 12 (04): : 1077 - 1095
  • [4] GSCHNEIDNER K, 2005, COMMUNICATION
  • [5] Performance of a room-temperature rotary magnetic refrigerator
    Okamura, Tetsuji
    Yamada, Kazuhiko
    Hirano, Naoki
    Nagaya, Shigeo
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1327 - 1331
  • [6] Magnetic refrigeration: Single and multimaterial active magnetic regenerator experiments
    Richard, MA
    Rowe, AM
    Chahine, R
    [J]. JOURNAL OF APPLIED PHYSICS, 2004, 95 (04) : 2146 - 2150
  • [7] Experimental investigation of a three-material layered active magnetic regenerator
    Rowe, A.
    Tura, A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1286 - 1293
  • [8] Rowe AM, 2002, AIP CONF PROC, V613, P995, DOI 10.1063/1.1472121
  • [9] Tura A, 2006, AIP CONF PROC, V823, P985
  • [10] Design and performance study of the active magnetic refrigerator for room-temperature application
    Zheng, Z. G.
    Yu, H. Y.
    Zhong, X. C.
    Zeng, D. C.
    Liu, Z. W.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01): : 78 - 86