Region of interest optimization for radiation therapy of breast cancer

被引:16
作者
Sauer, Tim-Oliver [1 ]
Ott, Oliver J. [1 ]
Lahmer, Godehard [1 ]
Fietkau, Rainer [1 ]
Bert, Christoph [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Univ Klinikum Erlangen, Dept Radiat Oncol, Univ Str 27, D-91054 Erlangen, Germany
关键词
breast cancer; radiation therapy; surface guided radiation therapy; SURFACE; RADIOTHERAPY; ACCURACY; SYSTEM; HOLD;
D O I
10.1002/acm2.13410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The goal of this study was to investigate how the choice of the region of interest (ROI) affects the registration results of surface imaging for daily positioning of breast cancer patients. Methods The AlignRT system (VisionRT, London) and the XVI Cone beam CT (CBCT; Elekta, Stockholm) installed on two Versa HD linacs (Elekta) were used in this study, which included 28 patients (160 fractions). In the clinical workflow, patients were prepositioned with AlignRT and then shifted in 6 degrees of freedom (DOF) according to the CBCT. A new reference capture was taken immediately afterward. Retrospectively, the surface capture resulting from prepositioning was registered to the latest reference capture. By varying the ROI used for registration, the surface-based results were optimized in terms of minimizing the deviation to the clinically applied CBCT shifts. Two sets of ROIs were used: one obtained by applying a variable margin to the breast surface, another by combining ROIs of anatomical structures, including the sternum and contralateral breast. Results Registration results showed significant differences from one ROI to another. Generally, the results improved with increasing ROI size, especially for rotational DOFs. ROIs, including the axilla or supraclavicular lymph drainage region, did not yield an improved registration result. On the other hand, an ROI comprising the breast surface, sternum, and a belt caudal to the breasts decreased the average magnitude of the translational and rotational deviations by 6.6% and 30.8% (p < 0.01), respectively, compared to the breast surface only results. Conclusion The influence of the ROI choice on surface imaging registration results was analyzed and the surface-based shifts were compared to clinically applied CBCT shifts. An optimal ROI for the treatment of breast cancer patients, consisting of the breast surface, sternum, and a belt, was identified.
引用
收藏
页码:152 / 160
页数:9
相关论文
共 18 条
[1]   Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy [J].
Alderliesten, Tanja ;
Sonke, Jan-Jakob ;
Betgen, Anja ;
Honnef, Joeri ;
van Vliet-Vroegindeweij, Corine ;
Remeijer, Peter .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02) :536-542
[2]  
Chung H, 2007, IFMBE PROC, V14, P1945
[3]   Surface imaging, laser positioning or volumetric imaging for breast cancer with nodal involvement treated by helical TomoTherapy [J].
Crop, Frederik ;
Pasquier, David ;
Baczkiewic, Amandine ;
Dore, Julie ;
Bequet, Lena ;
Steux, Emeline ;
Gadroy, Anne ;
Bouillon, Jacqueline ;
Florence, Clement ;
Muszynski, Laurence ;
Lacour, Mathilde ;
Lartigau, Eric .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05) :200-211
[4]   Recent advanced in Surface Guided Radiation Therapy [J].
Freislederer, P. ;
Kugele, M. ;
Ollers, M. ;
Swinnen, A. ;
Sauer, T. -O. ;
Bert, C. ;
Giantsoudi, D. ;
Corradini, S. ;
Batista, V. .
RADIATION ONCOLOGY, 2020, 15 (01)
[5]  
Hoisak JDP., 2020, Surface Guided Radiation Therapy, DOI DOI 10.1201/9780429489402
[6]   The Role of Optical Surface Imaging Systems in Radiation Therapy [J].
Hoisak, Jeremy D. P. ;
Pawlicki, Todd .
SEMINARS IN RADIATION ONCOLOGY, 2018, 28 (03) :185-193
[7]   Assessment of Setup Accuracy Using Anatomical Landmarks for Breast and Chest Wall Irradiation With Surface Guided Radiation Therapy [J].
Kost, Susan ;
Guo, Bingqi ;
Xia, Ping ;
Shah, Chirag .
PRACTICAL RADIATION ONCOLOGY, 2019, 9 (04) :239-247
[8]   Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy [J].
Kugele, Malin ;
Mannerberg, Annika ;
Bekke, Susanne Norring ;
Alkner, Sara ;
Berg, Lovisa ;
Mahmood, Faisal ;
Thornberg, Charlotte ;
Edvardsson, Anneli ;
Back, Sven A. J. ;
Behrens, Claus F. ;
Ceberg, Sofie .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09) :61-68
[9]   Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy [J].
Kugele, Malin ;
Edvardsson, Anneli ;
Berg, Lovisa ;
Alkner, Sara ;
Ljus, Carina Andersson ;
Ceberg, Sofie .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01) :25-38
[10]   AlignRT® and Catalyst™ in whole-breast radiotherapy with DIBH: Is IGRT still needed? [J].
Laaksomaa, Marko ;
Sarudis, Sebastian ;
Rossi, Maija ;
Lehtonen, Turkka ;
Pehkonen, Jani ;
Remes, Jenny ;
Luukkanen, Helmi ;
Skytta, Tanja ;
Kapanen, Mika .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03) :97-104