Analytical methodologies for broad metabolite coverage of exhaled breath condensate

被引:27
作者
Aksenov, Alexander A. [1 ]
Zamuruyev, Konstantin O. [1 ]
Pasamontes, Alberto [1 ]
Brown, Joshua F. [1 ]
Schivo, Michael [2 ,3 ]
Foutouhi, Soraya [4 ]
Weimer, Bart C. [4 ]
Kenyon, Nicholas J. [2 ,3 ]
Davis, Cristina E. [1 ]
机构
[1] Univ Calif Davis, Mech & Aerosp Engn, One Shields Ave, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Internal Med, 4150 V St,Suite 3400, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Ctr Comparat Resp Biol & Med, Davis, CA 95616 USA
[4] Univ Calif Davis, Sch Vet Med, 1089 Vet Med Dr, Davis, CA 95616 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1061卷
关键词
Exhaled breath condensate (EBC); Metabolites; Gas chromatography mass spectrometry (GC/MS); High performance liquid chromatography mass spectrometry (HPLC/MS); Hydrophilic interaction liquid chromatography (HILIC); Reversed-phase liquid chromatography (RP); VOLATILE ORGANIC-COMPOUNDS; CLINICAL-DIAGNOSIS; CANCER BIOMARKERS; METABOLOMICS; MS/MS; MS;
D O I
10.1016/j.jchromb.2017.06.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis.For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and nonvolatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage could be enhanced significantly with the use of organic solvent as a device rinse after breath sampling to collect the non-aqueous fraction as opposed to neat breath condensate sample. Here, we show the detected ranges of compounds in each case and provide a practical guide for methodology selection for optimal detection of specific compounds.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [1] Exhaled breath condensate: a comprehensive update
    Ahmadzai, Hasib
    Huang, Shuying
    Hettiarachchi, Ravin
    Lin, Jiun-Lih
    Thomas, Paul S.
    Zhang, Qi
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (07) : 1343 - 1361
  • [2] Metabolite Content Profiling of Bottlenose Dolphin Exhaled Breath
    Aksenov, Alexander A.
    Yeates, Laura
    Pasamontes, Alberto
    Siebe, Craig
    Zrodnikov, Yuriy
    Simmons, Jason
    McCartney, Mitchell M.
    Deplanque, Jean-Pierre
    Wells, Randall S.
    Davis, Cristina E.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (21) : 10616 - 10624
  • [3] Cellular Scent of Influenza Virus Infection.
    Aksenov, Alexander A.
    Sandrock, Christian E.
    Zhao, Weixiang
    Sankaran, Shankar
    Schivo, Michael
    Harper, Richart
    Cardona, Carol J.
    Xing, Zheng
    Davis, Cristina E.
    [J]. CHEMBIOCHEM, 2014, 15 (07) : 1040 - 1048
  • [4] Metabolomics in melon: A new opportunity for aroma analysis
    Allwood, J. William
    Cheung, William
    Xu, Yun
    Mumm, Roland
    De Vos, Ric C. H.
    Deborde, Catherine
    Biais, Benoit
    Maucourt, Mickael
    Berger, Yosef
    Schaffer, Arthur A.
    Rolin, Dominique
    Moing, Annick
    Hall, Robert D.
    Goodacre, Royston
    [J]. PHYTOCHEMISTRY, 2014, 99 : 61 - 72
  • [5] Analytical challenges in breath analysis and its application to exposure monitoring
    Alonso, Monica
    Sanchez, Juan M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 44 : 78 - 89
  • [6] Amann A, 2013, VOLATILE BIOMARKERS: NON-INVASIVE DIAGNOSIS IN PHYSIOLOGY AND MEDICINE, P1
  • [7] Amann A, 2011, EXPERT REV MOL DIAGN, V11, P207, DOI [10.1586/ERM.10.112, 10.1586/erm.10.112]
  • [8] Bajaj P., 2013, J. Anal. Sci. Methods Instrum, V03, P17
  • [9] Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
  • [10] 2-4