A Novel Continuum Robot Using Twin-Pivot Compliant Joints: Design, Modeling, and Validation

被引:83
作者
Dong, Xin [1 ]
Raffles, Mark [2 ]
Cobos-Guzman, Salvador [2 ]
Axinte, Dragos [3 ]
Kell, James [4 ]
机构
[1] Univ Nottingham, Dept Mech Mat & Mfg Engn, C31 Coates Bldg,Univ Pk, Nottingham NG7 2RD, England
[2] Univ Nottingham, Dept Mech Mat & Mfg Engn, Mfg Bldg,Univ Pk, Nottingham NG7 2RD, England
[3] Univ Nottingham, Dept Mech Mat & Mfg Engn, A63 Coates Bldg,Univ Pk, Nottingham NG7 2RD, England
[4] Rolls Royce PLC, Repair Technol, Derby DE24 8BJ, England
来源
JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME | 2016年 / 8卷 / 02期
基金
英国工程与自然科学研究理事会;
关键词
KINEMATICS; SYSTEM;
D O I
10.1115/1.4031340
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A twisting problem is identified from the central located flexible backbone continuum robot. Regarding this problem, a design solution is required to mechanically minimize this twisting angle along the backbone. Further, the error caused by the kinematic assumption of previous works is identified as well, which requires a kinematic solution to minimize. The scope of this paper is to introduce, describe and teste a novel design of continuum robot which has a twin-pivot compliant joint construction that minimizes the twisting around its axis. A kinematics model is introduced which can be applied to a wide range of twin-pivot construction with two pairs of cables per section design. And according to this model, the approach for minimising the kinematic error is developed. Furthermore, based on the geometry and material property of compliant joint, the work volumes for single/three-section continuum robot are presented, respectively. The kinematic analysis has been verified by a three-section prototype of continuum robot and adequate accuracy and repeatability tests carried out. And in the test, the system generates relatively small twisting angles when a range of end loads is applied at the end of the arm. Utilising the concept presented in this paper, it is possible to develop a continuum robot which can minimize the twisting angle and be accurately controlled. In this paper, a novel design of continuum robot which has a twin-pivot compliant joint construction that minimizes the twisting around its axis is introduced, described and tested. A kinematics model is introduced which can be applied to a wide range of twin-pivot construction with two pairs of cables per section design. Furthermore, based on the geometry and material property of compliant joint, the work volumes for single/three-section continuum robot are presented, respectively. Finally, the kinematic analysis has been verified by a three-section prototype of continuum and adequate accuracy and repeatability tests carried out.
引用
收藏
页数:14
相关论文
共 29 条
[1]   A fully autonomous microrobotic endoscopy system [J].
Asari, VK ;
Kumar, S ;
Kassim, IM .
JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2000, 28 (04) :325-341
[2]   Modeling and Control of a Continuum Style Microrobot for Endovascular Surgery [J].
Bailly, Yan ;
Amirat, Yacine ;
Fried, Georges .
IEEE TRANSACTIONS ON ROBOTICS, 2011, 27 (05) :1024-1030
[3]  
Chen G, 2013, 2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), P243, DOI [10.1109/ICMA.2013.6617925, 10.1109/CYBConf.2013.6617445]
[4]  
Chen Y, 2014, IEEE INT CONF ROBOT, P5393, DOI 10.1109/ICRA.2014.6907652
[5]   Design and analysis of a family of snake arm robots connected by compliant joints [J].
Dong, Xin ;
Raffles, Mark ;
Cobos Guzman, Salvador ;
Axinte, Dragos ;
Kell, James .
MECHANISM AND MACHINE THEORY, 2014, 77 :73-91
[6]  
Gravagne I. A., 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065), P2544, DOI 10.1109/ROBOT.2000.846411
[7]  
Hannan MW, 2001, IEEE ASME INT C ADV, P14, DOI 10.1109/AIM.2001.936423
[8]   Design of a novel snake-like robotic colonoscope [J].
Hu, Haiyan ;
Wang, Pengfei ;
Zhao, Bo ;
Li, Mantian ;
Sun, Lining .
2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2009), VOLS 1-4, 2009, :1957-+
[9]   Kinematics for multisection continuum robots [J].
Department of Electrical and Computer Engineering, Mississippi State University, Missippi State, MS 39762, United States ;
不详 .
IEEE Trans. Rob., 2006, 1 (43-55)
[10]   Practical kinematics for real-time implementation of continuum robots [J].
Jones, Bryan A. ;
Walker, Ian D. .
IEEE TRANSACTIONS ON ROBOTICS, 2006, 22 (06) :1087-1099