CT Metal Artifact Reduction by Dual Constrained Optimizations

被引:1
|
作者
Zhang, X. [1 ]
Xing, L. [1 ]
Wang, J. [1 ]
机构
[1] Stanford Univ, Stanford, CA 94305 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 78卷 / 03期
关键词
D O I
10.1016/j.ijrobp.2010.07.1684
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S726 / S727
页数:2
相关论文
共 50 条
  • [1] A Constrained Optimization Algorithm for CT Metal Artifact Reduction
    Zhang, X.
    Wang, J.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [2] Weighted Total Variation Constrained Reconstruction for Reduction of Metal Artifact in CT
    Zhang, Yanbo
    Mou, Xuanqin
    Yan, Hao
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2630 - 2634
  • [3] Metal Artifact Reduction in Cone-beam CT by Constrained Optimization
    Zhang, X.
    Wang, J.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S652 - S652
  • [4] DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
    Lin, Wei-An
    Liao, Haofu
    Peng, Cheng
    Sun, Xiaohang
    Zhang, Jingdan
    Luo, Jiebo
    Chellappa, Rama
    Zhou, Shaohua Kevin
    2019 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2019), 2019, : 10504 - 10513
  • [5] Fast streaking artifact reduction in CT using constrained optimization in metal masks
    August, J
    Kanade, T
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 2, PROCEEDINGS, 2004, 3217 : 1044 - 1045
  • [6] Dual-domain fusion network for metal artifact reduction in CT
    Wu, Jiayi
    Li, Yuan
    Wang, Zhe
    Wang, Huamin
    Tonetti, Maurizio S.
    Cao, Guohua
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [7] InDuDoNet: An Interpretable Dual Domain Network for CT Metal Artifact Reduction
    Wang, Hong
    Li, Yuexiang
    Zhang, Haimiao
    Chen, Jiawei
    Ma, Kai
    Meng, Deyu
    Zheng, Yefeng
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VI, 2021, 12906 : 107 - 118
  • [8] Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software
    Pessis, Eric
    Sverzut, Jean-Michel
    Campagna, Raphael
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 446 - 455
  • [9] A Model-based Scanning Scheme for CT Metal Artifact Reduction by Constrained Optimization
    Zhang, X.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S151 - S151
  • [10] CT Metal Artifact Reduction by Constrained Optimization with a Model-Based Scanning Scheme
    Zhang, X.
    Xing, L.
    MEDICAL PHYSICS, 2011, 38 (06) : 3402 - +