Mini-open Repair for Acute Achilles Tendon Rupture: Ring Forceps vs the Achillon Device

被引:7
作者
Park, Chul Hyun [1 ]
Yan, Hongfei [1 ]
Park, Jeongjin [1 ]
Chang, Min Cheol [2 ]
机构
[1] Yeungnam Univ, Coll Med, Dept Orthopaed Surg, Daegu, South Korea
[2] Yeungnam Univ, Coll Med, Dept Phys Med & Rehabil, Daegu, South Korea
关键词
Achilles tendon; acute rupture; repair; mini-open; CLINICAL-OUTCOMES; INVASIVE REPAIR; REHABILITATION; COMPLICATIONS; SYSTEM; ANKLE;
D O I
10.1177/03635465211044464
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Repair of acute Achilles tendon rupture using the Achillon device is a representative mini-open repair technique; however, the limitations of this technique include the need for special instruments and decreased repair strength. A modified mini-open repair using ring forceps might overcome these limitations. Purpose: To compare the Achillon device with ring forceps in mini-open repairs of acute Achilles tendon rupture. Study Design: Cohort study; Level of evidence, 3. Methods: Fifty patients (41 men and 9 women) with acute Achilles tendon rupture on 1 foot were consecutively treated using mini-open repair techniques. The first 20 patients were treated using the Achillon device (Achillon group), and the subsequent 30 were treated using a ring forceps (forceps group). Clinical, functional, and isokinetic results and postoperative complications were compared between the groups at the last follow-up. Clinical evaluations were performed using the AOFAS (American Orthopaedic Foot and Ankle Society) score, Achilles Tendon Total Rupture Score, length of incision, and operation time. Functional evaluations included active range of motion of the ankle joint, maximum calf circumference, hopping test, and single-limb heel rise (SLHR). Isokinetic evaluations were performed using the isokinetic test for ankle plantar flexion. Results: The AOFAS score (P = .669), Achilles Tendon Total Rupture Score (P = .753), and length of incision (P = .305) were not significantly different between the groups (mean +/- SD, 90.1 +/- 8.7, 88.3 +/- 9.9, and 2.7 +/- 0.3 cm in the Achillon group vs 92.2 +/- 9.4, 89.9 +/- 10.9, and 2.5 +/- 0.4 cm in the forceps group, respectively). Operation times in the Achillon group were significantly shorter than those in the forceps group (41.4 +/- 9.6 vs 62.8 +/- 14.1 minutes, P < .001). The maximum height of the SLHR (P = .042) and the number of SLHRs (P = .043) in the forceps group (79.7% +/- 7.4% and 72.9% +/- 10.2%) were significantly greater than those in the Achillon group (75.3% +/- 7.1% and 66.7% +/- 11.0%). No significant differences were detected between the groups in mean peak torques for plantar flexion at angular speeds of 30 deg/s (P = .185) and 120 deg/s (P = .271). There was no significant difference in the occurrence of postoperative complications between the groups (P = .093). Conclusion: The ring forceps technique is comparable to the Achillon technique with respect to clinical, functional, and isokinetic results and postoperative complications. Given that no special instrument is required, the ring forceps technique could be a better option for acute Achilles tendon rupture repair.
引用
收藏
页码:3613 / 3619
页数:7
相关论文
共 50 条
[21]   Achilles tendon repair: Achillon system vs. Krackow suture: An anatomic in vitro biomechanical study [J].
Huffard, B. ;
O'Loughlin, P. F. ;
Wright, T. ;
Deland, J. ;
Kennedy, J. G. .
CLINICAL BIOMECHANICS, 2008, 23 (09) :1158-1164
[22]   Traditional Open Repair and Reconstruction of Achilles Tendon Rupture [J].
Chien, Bonnie ;
Arciero, Emily .
TECHNIQUES IN FOOT AND ANKLE SURGERY, 2023, 22 (04) :169-172
[23]   Mini-Open Tenorrhaphy of Acute Achilles Tendon Ruptures Medium-Term Follow-up of 100 Cases [J].
Keller, Andres ;
Ortiz, Cristian ;
Wagner, Emilio ;
Wagner, Pablo ;
Mococain, Pablo .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (03) :731-736
[24]   Early rehabilitation after open repair for patients with a rupture of the Achilles tendon [J].
Kim, Uk ;
Choi, Yun Seong ;
Jang, Gyu Chol ;
Choi, Young Rak .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (07) :1710-1713
[25]   Midterm functional performance following open surgical repair of acute Achilles tendon rupture [J].
Wenning, Markus ;
Mauch, Marlene ;
Heitner, Albrecht ;
Streicher, Paul ;
Ritzmann, Ramona ;
Paul, Jochen .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (07) :1337-1349
[26]   Comparison of the open primary repair with augmentation and without augmentation in acute achilles tendon rupture [J].
Ocguder, Durmus Ali ;
Dogan, Metin ;
Bektaser, Suleyman Bulent ;
Akgun, Erkan ;
Tolunay, Tolga ;
Ugurlu, Mahmut .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2011, 41 (04) :639-646
[27]   A comparative study of innovative percutaneous repair and open repair for acute Achilles tendon rupture: Innovative usage of intraoperative ultrasonography [J].
Lee, Jeong-Kil ;
Kang, Chan ;
Hwang, Deuk-Soo ;
Kang, Dong-Hun ;
Lee, Gi-Soo ;
Hwang, Jung-Mo ;
Song, Jae-Hwang ;
Lee, Cheol-Won .
JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (01)
[28]   Open Re-rupture of the Achilles Tendon Following Minimally Invasive Repair: A Case Report [J].
Netto, Cesar de Cesar ;
Bernasconi, Alessio ;
Roberts, Lauren ;
Saito, Guilherme Honda ;
Hamilton, William G. ;
O'Malley, Martin J. .
JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (06) :1272-1277
[29]   Spontaneous Achilles tendon ruptures treated with a mini-open technique: clinical and functional evaluation [J].
De Carli, A. ;
Vadala, A. ;
Ciardini, R. ;
Iorio, R. ;
Ferretti, A. .
JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2009, 49 (03) :292-296
[30]   Outcomes of Limited Open Achilles Repair Using Modified Ring Forceps [J].
Telleria, Jessica J. M. ;
Smith, Jeremy T. ;
Ready, Lauren V. ;
Bluman, Eric M. .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (09)