A simulation-based evaluation of a graphic cardiovascular display

被引:17
作者
Albert, Robert W.
Agutter, James A.
Syroid, Noah D.
Johnson, Ken B.
Loeb, Robert G.
Westenskow, Dwayne R.
机构
[1] Appl Med Visualizat LLC, Salt Lake City, UT 84105 USA
[2] Univ Utah, Dept Architecture, Salt Lake City, UT USA
[3] Univ Utah, Dept Anesthesiol, Salt Lake City, UT USA
[4] Univ Arizona, Dept Anesthesiol, Tucson, AZ USA
关键词
D O I
10.1213/01.ane.0000282823.76059.ca
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A graphic presentation of complex information can facilitate early detection and management of adverse events. Prior work found that graphical presentation of selected cardiovascular variables led to earlier detection of a simulated ischemic event. Based on these findings, a second evaluation explored the utility of a graphical cardiovascular display (GCD) in a variety of simulated adverse cardiopulmonary events for two different display configurations. In this evaluation, we revised the GCD to present hemodynamic variables with or without a pulmonary artery catheter. Our hypotheses were that the revised GCD would improve detection of adverse cardiopulmonary events and add no additional. perceived workload. METHODS: Sixteen anesthesiologists and anesthesia residents were enrolled in a simulation-based evaluation of the GCD. Participants were randomly split into two groups balanced for expertise and asked to manage six simulated adverse cardiopulmonary events. The GCD was present in half of the simulations, balanced across scenarios and groups. Participants' verbalizations and actions during each scenario were recorded and transcribed. Transcripts of treatment interventions were subsequently rated by two blinded expert anesthesiologists. Perceived workload, time to detection, and proper treatment- of the adverse event were compared between groups. RESULTS: Experts ranked anesthesiologists using the GCD as being more effective overall and individually in three of six scenarios. Use of the GCD was demonstrated to influence the time to detection and the time to treatment of some critical events. There were no workload differences between display groups. DISCUSSION: Treatment intervention by participants using the GCD was rated superior by two blinded experts. The presence of the GCD resulted in a modest improvement in the time to detect myocardial ischemia and increased pulmonary capillary wedge pressure. The GCD may be a useful adjunct to monitor patients during adverse cardiopulmonary events. (Aresth Analg 2007;105:1303-11)
引用
收藏
页码:1303 / 1311
页数:9
相关论文
共 27 条
[11]  
Hart S. G., 1988, DEV NASA TLX TASK LO
[12]   Partial CO2 rebreathing indirect fick technique for non-invasive measurement of cardiac output [J].
Haryadi, DG ;
Orr, JA ;
Kuck, K ;
McJames, S ;
Westenskow, DR .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (5-6) :361-374
[13]  
Hotchkiss Melissa A, 2002, AANA J, V70, P470
[14]   Partial CO2 rebreathing cardiac output -: Operating principles of the NICO™ system [J].
Jaffe, MB .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (06) :387-401
[15]   Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery [J].
Kotake, Y ;
Moriyama, K ;
Innami, Y ;
Shimizu, H ;
Ueda, T ;
Morisaki, H ;
Takeda, J .
ANESTHESIOLOGY, 2003, 99 (02) :283-288
[16]  
Marascuilo L. A., 1977, Nonparametric and distribution-free methods for the social sciences
[17]   Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma [J].
Maxwell, RA ;
Gibson, JB ;
Slade, JB ;
Fabian, TC ;
Proctor, KG .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (05) :849-853
[18]   Comparison of continuous cardiac output measurements in patients after cardiac surgery [J].
Mielck, F ;
Buhre, W ;
Hanekop, G ;
Tirilomis, T ;
Hilgers, R ;
Sonntag, H .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) :211-216
[19]   Development of an objective scoring system for measurement of resident performance on the human patient simulator [J].
Scavone, Barbara M. ;
Sproviero, Michele T. ;
McCarthy, Robert J. ;
Wong, Cynthia A. ;
Sullivan, John T. ;
Siddall, Viva J. ;
Wade, Leonard D. .
ANESTHESIOLOGY, 2006, 105 (02) :260-266
[20]   Development and evaluation of a graphical anesthesia drug display [J].
Syroid, ND ;
Agutter, J ;
Drews, FA ;
Westenskow, DR ;
Albert, RW ;
Bermudez, JC ;
Strayer, DL ;
Prenzel, H ;
Loeb, RG ;
Weinger, MB .
ANESTHESIOLOGY, 2002, 96 (03) :565-575