Experimental study on control performance of tuned liquid column dampers considering different excitation directions

被引:40
作者
Altunisik, Ahmet Can [1 ]
Yetisken, Ali [1 ]
Kahya, Volkan [1 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkey
关键词
Ambient vibration test; Damping; Dynamic response; Ground motion; Shaking table; Tuned liquid column damper; VIBRATION CONTROL; TLCD;
D O I
10.1016/j.ymssp.2017.09.021
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper gives experimental tests' results for the control performance of Tuned Liquid Column Dampers (TLCDs) installed on a prototype structure exposed to ground motions with different directions. The prototype structure designed in the laboratory consists of top and bottom plates with four columns. Finite element analyses and ambient vibration tests are first performed to extract the natural frequencies and mode shapes of the structure. Then, the damping ratio of the structure as well as the resonant frequency, head-loss coefficient, damping ratio, and water height-frequency diagram of the designed TLCD are obtained experimentally by the shaking table tests. To investigate the effect of TLCDs on the structural response, the prototype structure-TLCD coupled system is considered later, and its natural frequencies and related mode shapes are obtained numerically. The acceleration and displacement time-histories are obtained by the shaking table tests to evaluate its damping ratio. To consider different excitation directions, the measurements are repeated for the directions between 0 and 90 with 15 increment. It can be concluded from the study that TLCD causes to decrease the resonant frequency of the structure with increasing of the total mass. Damping ratio considerably increases with installing TLCD on the structure. This is more pronounced for the angles of 0 degrees, 15 degrees, 30 degrees and 45 degrees. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 71
页数:13
相关论文
共 19 条
[1]   Modified liquid column damper for vibration control of structures [J].
Al-Saif, K. A. ;
Aldakkan, K. A. ;
Foda, M. A. .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2011, 53 (07) :505-512
[2]  
ANSYS, 2013, SWANS AN SYST
[3]   EFFECTIVENESS OF TUNED LIQUID COLUMN DAMPERS FOR VIBRATION CONTROL OF TOWERS [J].
BALENDRA, T ;
WANG, CM ;
CHEONG, HF .
ENGINEERING STRUCTURES, 1995, 17 (09) :668-675
[4]   Effects of TLCD with maneuverable flaps on vibration control of a SDOF structure [J].
Behbahani, Hamid Pesaran ;
bin Adnan, Azlan ;
Vafaei, Mohammadreza ;
Pheng, Ong Peng ;
Shad, Hossein .
MECCANICA, 2017, 52 (06) :1247-1256
[5]   Damping effects of the passive control devices on structural vibration control: TMD, TLC and TLCD for varying total masses [J].
Bigdeli, Yasser ;
Kim, Dookie .
KSCE JOURNAL OF CIVIL ENGINEERING, 2016, 20 (01) :301-308
[6]  
Chaiviryawong P, 2008, 14 WORLD C EARTHQ EN
[7]   Control performance of liquid column vibration absorbers [J].
Chang, CC ;
Hsu, CT .
ENGINEERING STRUCTURES, 1998, 20 (07) :580-586
[8]   Optimization of tuned liquid column dampers [J].
Gao, H ;
Kwok, KCS ;
Samali, B .
ENGINEERING STRUCTURES, 1997, 19 (06) :476-486
[9]   Improved reliability of wind turbine towers with tuned liquid column dampers (TLCDs) [J].
Mensah, Akwasi F. ;
Duenas-Osorio, Leonardo .
STRUCTURAL SAFETY, 2014, 47 :78-86
[10]  
Modal J, 2014, P 3 INT C MECH ENG M