Bipolar Membrane Electrodialysis for Ammonia Recovery from Synthetic Urine: Experiments, Modeling, and Performance Analysis

被引:60
|
作者
Li, Yujiao [1 ,2 ,3 ]
Wang, Ruoyu [1 ,3 ]
Shi, Shaoyuan [1 ,2 ,3 ]
Cao, Hongbin [1 ,2 ,3 ]
Yip, Ngai Yin [4 ,5 ]
Lin, Shihong [1 ,6 ]
机构
[1] Vanderbilt Univ, Dept Civil & Environm Engn, Nashville, TN 37235 USA
[2] Chinese Acad Sci, Inst Proc Engn, Beijing Engn Res Ctr Proc Pollut Control, Innovat Acad Green Manufacture, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Columbia Univ, Dept Earth & Environm Engn, New York, NY 10027 USA
[5] Columbia Univ, Columbia Water Ctr, New York, NY 10027 USA
[6] Vanderbilt Univ, Dept Chem & Bimol Engn, Nashville, TN 37235 USA
基金
美国国家科学基金会;
关键词
nutrient recovery; bipolar membrane electrodialysis; membrane contactor; source-separated urine; performance analysis; SOURCE-SEPARATED URINE; NITROGEN; REMOVAL; AGRICULTURE; EXTRACTION; CELL;
D O I
10.1021/acs.est.1c05316
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recovering nitrogen from source-separated urine is an important part of the sustainable nitrogen management. A novel bipolar membrane electrodialysis with membrane contactor (BMED-MC) process is demonstrated here for efficient recovery of ammonia from synthetic source-separated urine (similar to 3772 mg N L-1). In a BMED-MC process, electrically driven water dissociation in a bipolar membrane simultaneously increases the pH of the urine stream and produces an acid stream for ammonia stripping. With the increased pH of urine, ammonia transports across the gas-permeable membrane in the membrane contactor and is recovered by the acid stream as ammonium sulfate that can be directly used as fertilizer. Our results obtained using batch experiments demonstrate that the BMED-MC process can achieve 90% recovery. The average ammonia flux and the specific energy consumption can be regulated by varying the current density. At a current density of 20 mA cm(-2), the energy required to achieve a 67.5% ammonia recovery in a 7 h batch mode is 92.8 MJ kg(-1) N for a bench-scale system with one membrane stack and can approach 25.8 MJ kg(-1) N for large-scale systems with multiple membrane stacks, with an average ammonia flux of 2.2 mol m(-2) h(-1). Modeling results show that a continuous BMED-MC process can achieve a 90% ammonia recovery with a lower energy consumption (i.e., 12.5 MJ kg(-1) N). BMED-MC shows significant potential for ammonia recovery from source-separated urine as it is relatively energy-efficient and requires no external acid solution.
引用
收藏
页码:14886 / 14896
页数:11
相关论文
共 50 条
  • [11] Recovery of citric acid from fermented liquid by bipolar membrane electrodialysis
    Sun, Xiaohan
    Lu, Huixia
    Wang, Jianyou
    JOURNAL OF CLEANER PRODUCTION, 2017, 143 : 250 - 256
  • [12] Lactic acid recovery from fermentation by bipolar membrane electrodialysis and ionic migration
    Lin, Han
    Wang, Qunhui
    Wang, Lijuan
    Li, Yan
    Chen, Huanxi
    Huagong Xuebao/CIESC Journal, 2014, 65 (12): : 4823 - 4830
  • [13] Carbon dioxide recovery from carbonate solutions using bipolar membrane electrodialysis
    Iizuka, Atsushi
    Hashimoto, Kana
    Nagasawa, Hiroki
    Kumagai, Kazukiyo
    Yanagisawa, Yukio
    Yamasaki, Akihiro
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 101 : 49 - 59
  • [14] Removal and recovery of boric acid from waste water with bipolar membrane electrodialysis
    Yamasaki, Akihiro
    Nakamura, Yurina
    Itabashi, Misa
    Shoji, Tadashi
    Noguchi, Miyuki
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [15] Bipolar membrane electrodialysis for nutrient recovery from anaerobic digestion dewatering sidestream
    Chen, Weikun
    Grimberg, Stefan
    Rogers, Shane
    Kim, Taeyoung
    CHEMICAL ENGINEERING JOURNAL, 2024, 488
  • [16] Simultaneous Separation and Recovery of Phosphorus from Aqueous Solution by Bipolar Membrane Electrodialysis
    Iizuka, Atsushi
    Ho, Hsing-Jung
    Sugimoto, Tatsuya
    Adachi, Ken
    Shibata, Etsuro
    ISIJ INTERNATIONAL, 2023, 63 (07) : 1172 - 1177
  • [17] Recovery of acetic acid from dilute wastewater by means of bipolar membrane electrodialysis
    Yu, LX
    Guo, QF
    Hao, JH
    Jiang, WJ
    DESALINATION, 2000, 129 (03) : 283 - 288
  • [18] Comparison of bipolar membrane electrodialysis, electrodialysis metathesis, and bipolar membrane electrodialysis multifunction for the conversion of waste Na2SO4: Process performance and economic analysis
    Zhu, Ming
    He, Feiyu
    Feng, Ling
    Chi, Yongzhi
    Li, Yu-You
    Tian, Binghui
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 370
  • [19] Modeling for the Recovers of Organic Acid by Bipolar Membrane Electrodialysis
    Kim, Sang-Hun
    Lee, Byung-Chul
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2006, 44 (05): : 476 - 482
  • [20] Evaluation of treatment and recovery of leachate by bipolar membrane electrodialysis process
    Ilhan, F.
    Kabuk, H. A.
    Kurt, U.
    Avsar, Y.
    Sari, H.
    Gonullu, M. T.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 75 : 67 - 74