Age-dependent decline in parenchymal perfusion in the normal human pancreas: Measurement by dynamic computed tomography

被引:40
作者
Tsushima, Y [1 ]
Kusano, S [1 ]
机构
[1] Natl Def Med Coll, Dept Radiol, Saitama, Japan
关键词
tissue perfusion; computed tomography; contrast material;
D O I
10.1097/00006676-199808000-00006
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Parenchymal perfusion of the normal human pancreas using dynamic computed tomography (CT) was evaluated and correlated with patient demographic characteristics. The results of 23 patients (10 men and 13 women; age range, 25-71 years) who underwent enhanced CT of the upper abdomen and perfusion measurement were retrospectively reviewed. They had no evidence of pancreatic disease or diffuse liver disease, clinically or radiographically, Regions of interest were drawn in the pancreatic body and within the aorta. Pancreatic parenchymal perfusion per volume was then calculated by dividing the peak gradient of the pancreatic time-attenuation curve by the peak aortic CT number in increase. Perfusion in these pa tients ranged from 0.554 to 1.698 ml min(-1) ml(-1) (mean +/- SD, 0.963 +/- 0.064) and showed a negative correlation with the patient's age (r = 0.699, p < 0.0005). Pancreatic parenchymal density before contrast material injection (mean +/- SD, 48.86 +/- 0.978) was not correlated with perfusion measured by dynamic CT or age. No differences were observed in perfusion or density between men and women. In conclusion, parenchymal perfusion of the normal human pancreas measured by dynamic CT appears to decline with age.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 21 条
[1]  
Ashley S W, 1994, Gastrointest Endosc Clin N Am, V4, P369
[2]   LIVER PERFUSION STUDIED WITH ULTRAFAST CT [J].
BLOMLEY, MJK ;
COULDEN, R ;
DAWSON, P ;
KORMANO, M ;
DONLAN, P ;
BUFKIN, C ;
LIPTON, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) :424-433
[3]   Splenic blood flow: Evaluation with computed tomography [J].
Blomley, MJK ;
Kormano, M ;
Coulden, R ;
LimDunham, J ;
Dawson, P ;
Lipton, MJ .
ACADEMIC RADIOLOGY, 1997, 4 (01) :13-20
[4]   CONTRAST BOLUS DYNAMIC COMPUTED-TOMOGRAPHY FOR THE MEASUREMENT OF SOLID-ORGAN PERFUSION [J].
BLOMLEY, MJK ;
COULDEN, R ;
BUFKIN, C ;
LIPTON, MJ ;
DAWSON, P .
INVESTIGATIVE RADIOLOGY, 1993, 28 :S72-S77
[5]   MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN THE DOG USING ULTRAFAST COMPUTED-TOMOGRAPHY - EXPERIMENTAL VALIDATION [J].
GOBBEL, GT ;
CANN, CE ;
IWAMOTO, HS ;
FIKE, JR .
STROKE, 1991, 22 (06) :772-779
[6]   MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS BY ULTRAFAST CT [J].
GOULD, RG ;
LIPTON, MJ ;
MCNAMARA, MT ;
SIEVERS, RE ;
KOSHOLD, S ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1988, 23 (05) :348-353
[7]   AGE-RELATED MORPHOLOGY OF THE NORMAL PANCREAS ON COMPUTED-TOMOGRAPHY [J].
HEUCK, A ;
MAUBACH, PA ;
REISER, M ;
FEUERBACH, S ;
ALLGAYER, B ;
LUKAS, P ;
KAHN, T .
GASTROINTESTINAL RADIOLOGY, 1987, 12 (01) :18-22
[8]  
JASCHKE W, 1985, EUR J RADIOL, V5, P256
[9]   CINE-CT MEASUREMENT OF CORTICAL RENAL BLOOD-FLOW [J].
JASCHKE, WR ;
GOULD, RG ;
COGAN, MG ;
SIEVERS, R ;
LIPTON, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :779-784
[10]  
KLOTZ E, 1997, EUR RADIOL, V7, pS426