Indirect determination of uranium by the on-line reduction and fluorimetric detection of cerium(III)

被引:6
作者
Boonpanaid, C
Oguma, K
机构
[1] Chiba Univ, Grad Sch Sci & Technol, Inage Ku, Chiba 2638522, Japan
[2] Chiba Univ, Fac Engn, Dept Appl Chem, Inage Ku, Chiba 2638522, Japan
关键词
D O I
10.2116/analsci.21.155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow injection method has been developed for the indirect determination of uranium by the on-line reduction and subsequent fluorimetric detection of cerium(III). A sample solution containing uranium(VI), prepared as a sulfuric acid solution, was injected into a sulfuric acid carrier solution and passed through a column packed with metal bismuth to reduce uranium(VI) to uranium(IV). The sample solution was merged with a cerium(IV) solution to oxidize uranium(IV) to uranium(VI) and the cerium(III) generated was then monitored fluorimetricaly. The present method is free from interference from zirconium, lanthanides, and thorium, and has been successfully applied to the determination of uranium in monazite coupled with an anion-exchange separation in a sulfuric acid medium to eliminate iron(III). The sample throughput was 25 per hour and the lowest detectable concentration was 0.0042 mg l(-1).
引用
收藏
页码:155 / 159
页数:5
相关论文
共 21 条
[1]   Determination of uranium by flow injection inductively coupled plasma mass spectrometry [J].
Aldstadt, JH ;
Kuo, JM ;
Smith, LL ;
Erickson, MD .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :135-143
[2]   ONLINE TRACE ENRICHMENT AND DETERMINATION OF URANIUM IN WATERS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
DADFARNIA, S ;
MCLEOD, CW .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1331-1336
[3]   FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF URANIUM WITH IN-VALVE ION-EXCHANGE COLUMN PRECONCENTRATION AND SEPARATION [J].
GRUDPAN, K ;
LAIWRAUNGRATH, S ;
SOOKSAMITI, P .
ANALYST, 1995, 120 (08) :2107-2110
[4]   DETERMINATION OF URANIUM IN TIN TAILINGS USING 4-(2-PYRIDYLAZO) RESORCINOL BY FLOW-INJECTION ANALYSIS [J].
GRUDPAN, K ;
SOOKSAMITI, P ;
LAIWRAUNGRATH, S .
ANALYTICA CHIMICA ACTA, 1995, 314 (1-2) :51-55
[5]   FLUOROMETRIC-DETERMINATION OF URANIUM(VI) IN WATERS BY FLOW-INJECTION ANALYSIS AFTER PRECONCENTRATION ON A SILICA-GEL MICROCOLUMN [J].
HAVEL, J ;
VRCHLABSKY, M ;
KOHN, Z .
TALANTA, 1992, 39 (07) :795-799
[6]   Simultaneous spectrophotometric determination of uranium and thorium by flow injection analysis using selective masking [J].
Hirano, Y ;
Ogawa, Y ;
Oguma, K .
ANALYTICAL SCIENCES, 2003, 19 (02) :303-307
[8]  
Kuwabara J, 2002, J NUCL SCI TECHNOL S, V3, P556
[9]  
Lee K. H., 2002, J FLOW INJECT ANAL, V19, P39
[10]   Inductively coupled plasma mass spectrometric determination of heavy metals in sea-water samples after pre-treatment with a chelating resin disk by an on-line flow injection method [J].
Lee, KH ;
Oshima, M ;
Motomizu, S .
ANALYST, 2002, 127 (06) :769-774