Investigation of the Combined Effect of Variable Inlet Guide Vane Drift, Fouling, and Inlet Air Cooling on Gas Turbine Performance

被引:14
作者
Hashmi, Muhammad Baqir [1 ]
Lemma, Tamiru Alemu [1 ]
Karim, Zainal Ambri Abdul [1 ]
机构
[1] Univ Teknol PETRONAS, Dept Mech Engn, Tronoh 31750, Perak Darul Rid, Malaysia
关键词
variable geometry; industrial gas turbine; variable inlet guide vane drift; fouling; inlet air cooling; IMPROVEMENT; SIMULATION; CYCLE;
D O I
10.3390/e21121186
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Variable geometry gas turbines are susceptible to various malfunctions and performance deterioration phenomena, such as variable inlet guide vane (VIGV) drift, compressor fouling, and high inlet air temperatures. The present study investigates the combined effect of these performance deterioration phenomena on the health and overall performance of a three-shaft gas turbine engine (GE LM1600). For this purpose, a steady-state simulation model of the turbine was developed using a commercial software named GasTurb 12. In addition, the effect of an inlet air cooling (IAC) technique on the gas turbine performance was examined. The design point results were validated using literature results and data from the manufacturer's catalog. The gas turbine exhibited significant deterioration in power output and thermal efficiency by 21.09% and 7.92%, respectively, due to the augmented high inlet air temperature and fouling. However, the integration of the inlet air cooling technique helped in improving the power output, thermal efficiency, and surge margin by 29.67%, 7.38%, 32.84%, respectively. Additionally, the specific fuel consumption (SFC) was reduced by 6.88%. The VIGV down-drift schedule has also resulted in improved power output, thermal efficiency, and the surge margin by 14.53%, 5.55%, and 32.08%, respectively, while the SFC decreased by 5.23%. The current model can assist in troubleshooting the root cause of performance degradation and surging in an engine faced with VIGV drift and fouling simultaneously. Moreover, the combined study also indicated the optimum schedule during VIGV drift and fouling for performance improvement via the IAC technique.
引用
收藏
页数:26
相关论文
共 34 条
[1]  
Aker G. F., 1989, Transactions of the ASME. Journal of Engineering for Gas Turbines and Power, V111, P343
[2]   Augmentation of gas turbine performance using air coolers [J].
Alhazmy, MM ;
Najjar, YSH .
APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) :415-429
[3]   Performance improvement of gas turbine power plants by utilizing turbine inlet air-cooling (TIAC) technologies in Riyadh, Saudi Arabia [J].
Baakeem, Saleh S. ;
Orfi, Jamel ;
Al-Ansary, Hany .
APPLIED THERMAL ENGINEERING, 2018, 138 :417-432
[4]  
Bringhenti C, 2006, PROCEEDINGS OF THE ASME TURBO EXPO 2006, VOL 6, PTS A AND B, P1941
[5]   Analysis of combustion turbine inlet air cooling systems applied to an operating cogeneration power plant [J].
Chacartegui, R. ;
Jimenez-Espadafor, F. ;
Sanchez, D. ;
Sanchez, T. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (08) :2130-2141
[6]  
Cruz-Manzo S., 2018, P INT GAS TURB C BRU
[7]  
Diakunchak I.S., 1991, P ASME 1991 INT GAS, pV004T010A012
[8]   Performance improvement of power plants using absorption cooling system [J].
Elberry, M. F. ;
Elsayed, A. A. ;
Teamah, M. A. ;
Abdel-Rahman, A. A. ;
Elsafty, A. F. .
ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (04) :2679-2686
[9]  
Enyia J.D., 2015, Int. J. Eng. Res. Technol, V4, P500
[10]  
Escher P., 1995, OBJECT ORIENTATED GA