Incorporation of Glutamic Acid or Amino-Protected Glutamic Acid into Poly(Glycerol Sebacate): Synthesis and Characterization

被引:4
作者
Jiang, Yi-Sheng [1 ]
Hu, Ming-Hsien [2 ,3 ]
Jan, Jeng-Shiung [1 ,4 ]
Hu, Jin-Jia [5 ]
机构
[1] Natl Cheng Kung Univ, Dept Chem Engn, Tainan 70101, Taiwan
[2] Da Yeh Univ, Bachelor Program Design & Mat Med Equipment & Dev, Changhua 515, Taiwan
[3] Showchwan Mem Hosp, Orthoped Dept, Changhua 500, Taiwan
[4] Natl Cheng Kung Univ, Hierarch Green Energy Mat HiGEM Res Ctr, Tainan 70101, Taiwan
[5] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, Hsinchu 300, Taiwan
关键词
poly(glycerol sebacate); poly(ester amide); elastomer; lipase; pi-pi stacking interactions; pi stacking; soft tissue engineering; MECHANICAL-PROPERTIES; POLY(ESTER AMIDE)S; FIBROUS MEMBRANES; DEGRADATION; FABRICATION; PGS;
D O I
10.3390/polym14112206
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Poly(glycerol sebacate) (PGS), a soft, tough elastomer with excellent biocompatibility, has been exploited successfully in many tissue engineering applications. Although tunable to some extent, the rapid in vivo degradation kinetics of PGS is not compatible with the healing rate of some tissues. The incorporation of L-glutamic acid into a PGS network with an aim to retard the degradation rate of PGS through the formation of peptide bonds was conducted in this study. A series of poly(glycerol sebacate glutamate) (PGSE) containing various molar ratios of sebacic acid/L-glutamic acid were synthesized. Two kinds of amino-protected glutamic acids, Boc-L-glutamic acid and Z-L-glutamic acid were used to prepare controls that consist of no peptide bonds, denoted as PGSE-B and PGSE-Z, respectively. The prepolymers were characterized using H-1-NMR spectroscopy. Cured elastomers were characterized using FT-IR, DSC, TGA, mechanical testing, and contact angle measurement. In vitro enzymatic degradation of PGSE over a period of 28 days was investigated. FT-IR spectroscopy confirmed the formation of peptide bonds. The glass transition temperature for the elastomer was found to increase as the ratio of sebacic acid/glutamic acid was increased to four. The decomposition temperature of the elastomer decreased as the amount of glutamic acid was increased. PGSE exhibited less stiffness and larger elongation at break as the ratio of sebacic acid/glutamic acid was decreased. Notably, PGSE-Z was stiffer and had smaller elongation at break than PGSE and PGSE-B at the same molar ratio of monomers. The results of in vitro enzymatic degradation demonstrated that PGSE has a lower degradation rate than does PGS, whereas PGSE-B and PGSE-Z degrade at a greater rate than does PGS. SEM images suggest that the degradation of these crosslinked elastomers is due to surface erosion. The cytocompatibility of PGSE was considered acceptable although slightly lower than that of PGS. The altered mechanical properties and retarded degradation kinetics for PGSE reflect the influence of peptide bonds formed by the introduction of L-glutamic acid. PGSE displaying a lower degradation rate compared to that for PGS can be used as a scaffold material for the repair or regeneration of tissues that are featured by a low healing rate.
引用
收藏
页数:13
相关论文
共 46 条
  • [1] An elastomeric patch derived from poly(glycerol sebacate) for delivery of embryonic stem cells to the heart
    Chen, Qi-Zhi
    Ishii, Hikaru
    Thouas, George A.
    Lyon, Alexander R.
    Wright, Jamie S.
    Blaker, Jonny J.
    Chrzanowski, Wojciech
    Boccaccini, Aldo R.
    Ali, Nadire N.
    Knowles, Jonathan C.
    Harding, Sian E.
    [J]. BIOMATERIALS, 2010, 31 (14) : 3885 - 3893
  • [2] A comparative study on in vitro enzymatic degradation of poly(glycerol sebacate) and poly(xylitol sebacate)
    Chen, Qizhi
    Yang, Xueyuan
    Li, Yuan
    [J]. RSC ADVANCES, 2012, 2 (10): : 4125 - 4134
  • [3] π-π Stacking Interaction: A Nondestructive and Facile Means in Material Engineering for Bioapplications
    Chen, Tao
    Li, Meixiu
    Liu, Jingquan
    [J]. CRYSTAL GROWTH & DESIGN, 2018, 18 (05) : 2765 - 2783
  • [4] Physiologic compliance in engineered small-diameter arterial constructs based on an elastomeric substrate
    Crapo, Peter M.
    Wang, Yadong
    [J]. BIOMATERIALS, 2010, 31 (07) : 1626 - 1635
  • [5] Influence of Glutamic Acid on the Properties of Poly(xylitol glutamate sebacate) Bioelastomer
    Dong, Weifu
    Li, Ting
    Xiang, Shuangfei
    Ma, Piming
    Chen, Mingqing
    [J]. POLYMERS, 2013, 5 (04) : 1339 - 1351
  • [6] Accordion-like honeycombs for tissue engineering of cardiac anisotropy
    Engelmayr, George C., Jr.
    Cheng, Mingyu
    Bettinger, Christopher J.
    Borenstein, Jeffrey T.
    Langer, Robert
    Freed, Lisa E.
    [J]. NATURE MATERIALS, 2008, 7 (12) : 1003 - 1010
  • [7] Gunatillake P, 2006, BIOTECHNOL ANN REV, V12, P301, DOI 10.1016/S1387-2656(06)12009-8
  • [8] Horrocks R., 1992, HDB POLYM DEGRADATIO
  • [9] Fabrication of a mechanically anisotropic poly(glycerol sebacate) membrane for tissue engineering
    Hsu, Chi-Nung
    Lee, Pei-Yuan
    Tuan-Mu, Ho-Yi
    Li, Chen-Yu
    Hu, Jin-Jia
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (02) : 760 - 770
  • [10] Influence of Specimen Geometry on the Estimation of the Planar Biaxial Mechanical Properties of Cruciform Specimens
    Hu, J. -J.
    Chen, G. -W.
    Liu, Y. -C.
    Hsu, S. -S.
    [J]. EXPERIMENTAL MECHANICS, 2014, 54 (04) : 615 - 631