Low-temperature sorption-luminescence determination of platinum using silica chemically modified with dithiocarbamate groups

被引:7
|
作者
Losev, V. N. [1 ]
Elsuf'ev, E. V. [1 ]
Trofimchuk, A. K. [2 ]
Legenchuk, A. V. [2 ]
机构
[1] Kristal Res Engn Ctr, Krasnoyarsk 660041, Russia
[2] Taras Shevchenko Kiev Natl Univ, UA-01033 Kiev, Ukraine
关键词
chemically modified silica; dithiocarbamates; luminescence; platinum; COMPLEXES;
D O I
10.1134/S1061934812090067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Application of silica chemically modified with dithiocarbamate groups (DTCS) has been proposed for the low-temperature sorption-luminescence determination of platinum. The establishment of a sorption equilibrium in the platinum(IV) and platinum(II) extraction with DTCS from hydrochloric acid solutions takes 20 and 2 min, respectively. If the duration of the phase contact is optimal, the recovery achieves 99% in the acidity range from 4 M of HCl to pH 5. The sorption of platinum(IV) and platinum(II) results in the formation of coordination compounds of platinum(II) on the surface of the adsorbent which are luminescent in ultraviolet light when frozen (77 K). A procedure has been developed for low-temperature sorption-luminescence determination of platinum with the detection limit of 0.5 mu g of platinum per 0.1 g of the adsorbent and linearity of the calibration curve to 25 mu g/0.1 g. The developed procedure has been applied to the determination of platinum in the samples of alumoplatinum catalyst.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [11] Highly sensitive sorption-luminescence determination of trace europium with preconcentration on silica chemically modified with iminodiacetic acid
    Voronina, R. D.
    Zorov, N. B.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (03) : 206 - 212
  • [12] Highly sensitive sorption-luminescence determination of trace europium with preconcentration on silica chemically modified with iminodiacetic acid
    Voronina, R.D.
    Zorov, N.B.
    Journal of Analytical Chemistry, 2007, 62 (03): : 206 - 212
  • [13] Highly sensitive sorption-luminescence determination of trace europium with preconcentration on silica chemically modified with iminodiacetic acid
    R. D. Voronina
    N. B. Zorov
    Journal of Analytical Chemistry, 2007, 62 : 206 - 212
  • [14] Sorption-luminescence determination of gold, silver, and platinum with the use of silica gel chemically modified with N-(1,3,4-thiodiazole-2-thiol)-N′-propylurea groups
    V. N. Losev
    S. I. Metelitsa
    E. V. Elsuf’ev
    A. K. Trofimchuk
    Journal of Analytical Chemistry, 2009, 64 : 903 - 909
  • [15] Sorption-Luminescence Determination of Gold, Silver, and Platinum with the Use of Silica Gel Chemically Modified with N-(1,3,4-Thiodiazole-2-Thiol)-N′-Propylurea Groups
    Losev, V. N.
    Metelitsa, S. I.
    Elsuf'ev, E. V.
    Trofimchuk, A. K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (09) : 903 - 909
  • [16] Sorption-luminescence determination of gold, silver, and platinum with the use of silica gel chemically modified with n-(1,3,4-thiodiazole-2-thiol)-n- propylurea groups
    Losev, V.N.
    Metelitsa, S.I.
    Elsuf'Ev, E.V.
    Trofimchuk, A.K.
    Journal of Analytical Chemistry, 2009, 64 (09): : 903 - 909
  • [17] Sorption-luminescence method for determination of europium using acid-modified clinoptilolite
    Vasylechko, Volodymyr O.
    Gryshchouk, Galyna V.
    Kalychak, Yaroslav M.
    Vasylechko, Leonid O.
    Voloshinovskii, Anatoliy S.
    Vistovskyy, Vitaliy V.
    Tupys, Andrii M.
    APPLIED NANOSCIENCE, 2019, 9 (05) : 1145 - 1153
  • [18] LOW-TEMPERATURE LUMINESCENCE DETERMINATION OF PLATINUM WITH THIOUREA
    PAKHOMOVA, IG
    KUZYAKOVA, NY
    FADEEVA, VI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (08): : 1194 - 1197
  • [19] Sorption-Luminescence Determination of Aluminium using Silica Gel Modified with Polyhexamethylene Guanidine and 8-Oxyquinoline-5-Sulfonic Acid
    Losev, Vladimir N.
    Metelitsa, Sergey I.
    JOURNAL OF SIBERIAN FEDERAL UNIVERSITY-CHEMISTRY, 2009, 2 (03): : 246 - 253
  • [20] Sorption-luminescence method for determination of terbium using Transcarpathian clinoptilolite
    Vasylechko, V. O.
    Gryshchouk, G. V.
    Zakordonskiy, V. P.
    Vasylechko, L. O.
    Schmidt, M.
    Leshchack, I. M.
    Kalychak, Ya. M.
    Bagday, S. R.
    TALANTA, 2017, 174 : 486 - 492