Volume Status in Patients on Peritoneal Dialysis: The Role of Apelin and Bio-Impedance Spectroscopy

被引:5
作者
Kazancioglu, Rumeyza [1 ]
Gursu, Meltem [2 ]
Karadag, Serhat [2 ]
Tatli, Emel [2 ]
Aydin, Zeki [2 ]
Uzun, Sami [2 ]
Sumnu, Abdullah [2 ]
Cebeci, Egemen [2 ]
Ozturk, Savas [2 ]
机构
[1] Bezmialem Vakif Univ, Dept Nephrol, Fac Med, Istanbul, Turkey
[2] Haseki Training & Res Hosp, Dept Nephrol, Istanbul, Turkey
关键词
apelin; bio-impedance spectroscopy; echocardiography; hypervolemia; peritoneal dialysis; BLOOD-PRESSURE; BODY-COMPOSITION; PEPTIDE APELIN; FLUID STATUS; RECEPTOR; APJ; ULTRAFILTRATION; PREDICTORS; MORTALITY; OVERLOAD;
D O I
10.3109/0886022X.2012.712860
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
One of the main factors determining the survival of peritoneal dialysis (PD) patients is volume status. We aimed to investigate hydration status of PD patients by bio-impedance spectroscopy (BIS) and echocardiography and to study the relation of them with apelin, which has effects related with volume status like vasodilation, positive inotropism, and inhibition of ADH release and RAS antagonism. Chronic PD patients without active cardiac disease or clinically prominent hypervolemia were included. Besides the demographic, clinical, and laboratory data, BIS and echocardiographic findings together with apelin levels were recorded. The study included 21 patients. Of them, eight patients were euvolemic, one patient was hypovolemic, and others have some degree of overhydration (1.1-6.8 L) with BIS, although all were euvolemic clinically. Mean apelin level was 1.49 +/- 0.49 ng/mL. Apelin level was positively correlated with ejection fraction and negatively with total body water (TBW), intracellular and extracellular water, lean tissue mass, and left atrium diameter. On linear regression model, TBW was the major determinant of apelin. Although apelin is expected to increase in hypervolemic patients, the negative correlation with body water in this study may be related with yet unknown role of apelin in dialyzed patients. They may have important roles in volume status in future.
引用
收藏
页码:1068 / 1073
页数:6
相关论文
共 50 条
[41]   THE ASSOCIATION BETWEEN ARTERIAL STIFFNESS AND FLUID STATUS IN PERITONEAL DIALYSIS PATIENTS [J].
Kocyigit, Ismail ;
Sipahioglu, Murat Hayri ;
Orscelik, Ozcan ;
Unal, Aydin ;
Celik, Ahmet ;
Abbas, Samer R. ;
Zhu, Fansan ;
Tokgoz, Bulent ;
Dogan, Ali ;
Oymak, Oktay ;
Kotanko, Peter ;
Levin, Nathan W. .
PERITONEAL DIALYSIS INTERNATIONAL, 2014, 34 (07) :781-790
[42]   Residual renal function and volume status in peritoneal dialysis patients: a conflict of interest? [J].
Van Biesen, Wim ;
Lameire, Norbert ;
Verbelke, Francis ;
Vanholder, Raymond .
JOURNAL OF NEPHROLOGY, 2008, 21 (03) :299-304
[43]   Periodontal status of patients undergoing peritoneal dialysis or hemodialysis [J].
Ma, Lili ;
Jin, Xin ;
Cao, Yali ;
Xu, Zhihong ;
Xing, Shuning ;
Xu, Baohua .
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08) :16759-16764
[44]   The Role of Dyslipidemia in Atherogenesis in Peritoneal Dialysis Patients [J].
Rebic, Damir ;
Begic, Edin ;
Aziri, Buena ;
Dzubur, Alen ;
Gogic, Ena ;
Durak-Nalbantic, Azra ;
Hamzic-Mehmedbasic, Aida ;
Hasanspahic, Senad ;
Granov, Nermir .
ADVANCED BIOMEDICAL RESEARCH, 2023, 12 (01)
[45]   Is Extracellular Volume Expansion of Peritoneal Dialysis Patients Associated with Greater Urine Output? [J].
Davenport, Andrew ;
Sayed, Rabya Hussain ;
Fan, Stanley .
BLOOD PURIFICATION, 2011, 32 (03) :226-231
[46]   The effects of low-sodium peritoneal dialysis fluids on blood pressure, thirst and volume status [J].
Davies, Simon ;
Carlsson, Ola ;
Simonsen, Ole ;
Johansson, Ann-Cathrine ;
Venturoli, Daniele ;
Ledebo, Ingrid ;
Wieslander, Anders ;
Chan, Cian ;
Rippe, Bengt .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (05) :1609-1617
[47]   Influence of peritoneal dialysis solution on measurements of fluid status by bioimpedance spectroscopy [J].
Simon Paul Parmentier ;
Holger Schirutschke ;
Bertram Schmitt ;
Jens Schewe ;
Kay Herbrig ;
Frank Pistrosch ;
Jens Passauer .
International Urology and Nephrology, 2013, 45 :229-232
[48]   The Effect of Strict Volume Control Assessed by Repeated Bioimpedance Spectroscopy on Cardiac Function in Peritoneal Dialysis Patients [J].
Hong, Yu Ah ;
Yoon, Hye Eun ;
Choi, Bum Soon ;
Shin, Seok Joon ;
Kim, Yong-Soo ;
Lee, So Young ;
Lee, Sang-Ho ;
Kim, Su Hyun ;
Lee, Eun Young ;
Shin, Sug Kyun ;
Kwon, Young Joo ;
Kim, Jeong Ho ;
Chang, Yoon Kyung ;
Kim, Suk Young ;
Kim, Ji Eun ;
Ahn, Shin Young ;
Ko, Gang Jee .
SCIENTIFIC REPORTS, 2019, 9 (1)
[49]   Design and Preliminary Test of A Palm Bio-Impedance Spectroscopy Measurement System for Biometric Authentication [J].
Yang, Yuxiang ;
Zhang, Wen ;
Sun, Qiang .
2014 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2014), 2014, :824-827
[50]   A comparison of fluid status determination using bioelectric impedance and the isotope dilution method in hemodialysis and peritoneal dialysis patients [J].
Dou, Yanna ;
Gong, Yanan ;
Li, Afang ;
Wang, Peipei ;
Song, Dongyan ;
Wang, Yuyang ;
Liu, Dong ;
Cheng, Genyang ;
Zhao, Zhanzheng .
RENAL FAILURE, 2022, 44 (01) :1698-1707