TITAN project status report and a proposal for a new cooling method of highly charged ions

被引:14
作者
Ryjkov, VL [1 ]
Blomeley, L
Brodeur, M
Grothkopp, P
Smith, M
Bricault, P
Buchinger, F
Crawford, J
Gwinner, G
Lee, J
Vaz, J
Werth, G
Dilling, J
机构
[1] TRIUMF Natl Lab, Vancouver, BC, Canada
[2] Univ British Columbia, Dept Phys, Vancouver, BC, Canada
[3] Univ Manitoba, Winnipeg, MB, Canada
[4] McGill Univ, Dept Phys, Montreal, PQ, Canada
[5] Johannes Gutenberg Univ Mainz, Dept Phys, Mainz, Germany
关键词
D O I
10.1140/epjad/i2005-06-122-1
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The TITAN facility for precision mass measurements of short-lived isotopes is currently being constructed at the ISAC radioactive beam facility at TRIUMF, Vancouver, Canada. Current status and developments in the project are reported. A new method for cooling of highly charged ions (HCI) with singly charged ions in a Penning trap, critically needed for precision measurements, is presented. Estimates show that the technique is promising and can be applied to cooling of highly charged short-lived isotope ions without recombination losses.
引用
收藏
页码:53 / 56
页数:4
相关论文
共 16 条
[1]   SMILETRAP -: A Penning trap facility for precision mass measurements using highly charged ions [J].
Bergström, I ;
Carlberg, C ;
Fritioff, T ;
Douysset, G ;
Schönfelder, J ;
Schuch, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (03) :618-651
[2]   Electron and positron cooling of highly charged ions in a cooler Penning trap [J].
Bernard, J ;
Alonso, J ;
Beier, T ;
Block, M ;
Djekic, S ;
Kluge, HJ ;
Kozhuharov, C ;
Quint, W ;
Stahl, S ;
Valenzuela, T ;
Verdú, J ;
Vogel, M ;
Werth, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 532 (1-2) :224-228
[3]   Pushing the relative mass accuracy limit of ISOLTRAP on exotic nuclei below 10 ppb [J].
Blaum, K ;
Beck, D ;
Bollen, G ;
Herfurth, F ;
Kellerbauer, A ;
Kluge, HJ ;
Moore, RB ;
Sauvan, E ;
Scheidenberger, C ;
Schwarz, S ;
Schweikhard, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 204 :478-481
[4]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[5]   BOLOMETRIC TECHNIQUE FOR RF SPECTROSCOPY OF STORED IONS [J].
DEHMELT, HG ;
WALLS, FL .
PHYSICAL REVIEW LETTERS, 1968, 21 (03) :127-&
[6]   The proposed TITAN facility at ISAC for very precise mass measurements on highly charged short-lived isotopes [J].
Dilling, J ;
Bricault, P ;
Smith, M ;
Kluge, HJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 204 :492-496
[7]   A DIRECT DETERMINATION OF THE PROTON ELECTRON MASS RATIO [J].
GRAFF, G ;
KALINOWSKY, H ;
TRAUT, J .
ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1980, 297 (01) :35-39
[8]   Electron cooling of protons in a nested penning trap [J].
Hall, DS ;
Gabrielse, G .
PHYSICAL REVIEW LETTERS, 1996, 77 (10) :1962-1965
[9]   A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams [J].
Herfurth, F ;
Dilling, J ;
Kellerbauer, A ;
Bollen, G ;
Henry, S ;
Kluge, HJ ;
Lamour, E ;
Lunney, D ;
Moore, RB ;
Scheidenberger, C ;
Schwarz, S ;
Sikler, G ;
Szerypo, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 469 (02) :254-275
[10]   Measurement of cross-magnetic-field heat transport in a pure ion plasma [J].
Hollmann, EM ;
Anderegg, F ;
Driscoll, CF .
PHYSICAL REVIEW LETTERS, 1999, 82 (24) :4839-4842