A compact flat-response x-ray detector for the radiation flux in the range from 1.6 keV to 4.4 keV

被引:43
作者
Guo, Liang [1 ,2 ,3 ]
Li, Sanwei [3 ]
Zheng, Jian [1 ,2 ]
Li, Zhichao [3 ]
Yang, Dong [3 ]
Du, Huabin [3 ]
Hou, Lifei [3 ]
Cui, Yanli [3 ]
Yang, Jiamin [3 ]
Liu, Shenye [3 ]
Jiang, Shaoen [3 ]
Ding, Yongkun [3 ]
机构
[1] Univ Sci & Technol China, CAS Key Lab Basic Plasma Phys, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
[3] China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Sichuan, Peoples R China
关键词
flat-response; compact; compound filter; M-band x-ray; SPECTROMETER; IGNITION;
D O I
10.1088/0957-0233/23/6/065902
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A band-pass flat-response x-ray detector is designed to measure the absolute M-band x-ray flux. The detector comprises an x-ray diode and a compound filter that is carefully designed to achieve the desired response function in the range from 1.6 to 4.4 keV, i.e. the flatness of the spectral response is better than 5%. The designed response function is in excellent agreement with the calibrated one, indicating that the x-ray detector with various responses can be achieved with the state-of-art fabrication technique.
引用
收藏
页数:6
相关论文
共 27 条
[1]  
Amendt PA, 2005, PHYS REV LETT, V94, DOI [10.1103/PhysRevLett.94.065004, 10.1103/PhysLettRev.94.065004]
[2]   Experimental study of the interaction of subpicosecond laser pulses with solid targets of varying initial scale lengths [J].
Bastiani, S ;
Rousse, A ;
Geindre, JP ;
Audebert, P ;
Quoix, C ;
Hamoniaux, G ;
Antonetti, A ;
Gauthier, JC .
PHYSICAL REVIEW E, 1997, 56 (06) :7179-7185
[3]   Spectral response calibrations of x-ray diode photocathodes in the 50-5900 eV photon energy region [J].
Bentley, CD ;
Simmons, AC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :1202-1204
[4]   Omega dante soft x-ray power diagnostic component calibration at the National Synchrotron Light Source [J].
Campbell, KM ;
Weber, FA ;
Dewald, EL ;
Glenzer, SH ;
Landen, OL ;
Turner, RE ;
Waide, PA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3768-3771
[5]   Plastic ablator ignition capsule design for the National Ignition Facility [J].
Clark, Daniel S. ;
Haan, Steven W. ;
Hammel, Bruce A. ;
Salmonson, Jay D. ;
Callahan, Debra A. ;
Town, Richard P. J. .
PHYSICS OF PLASMAS, 2010, 17 (05)
[6]   X-ray conversion efficiency of high-Z hohlraum wall materials for indirect drive ignition [J].
Dewald, E. L. ;
Rosen, M. ;
Glenzer, S. H. ;
Suter, L. J. ;
Girard, F. ;
Jadaud, J. P. ;
Schein, J. ;
Constantin, C. ;
Wagon, F. ;
Huser, G. ;
Neumayer, P. ;
Landen, O. L. .
PHYSICS OF PLASMAS, 2008, 15 (07)
[7]   Broad M-band multi-keV x-ray emission from plasmas created by short laser pulses [J].
Harmand, M. ;
Dorchies, F. ;
Peyrusse, O. ;
Descamps, D. ;
Fourment, C. ;
Hulin, S. ;
Petit, S. ;
Santos, J. J. .
PHYSICS OF PLASMAS, 2009, 16 (06)
[8]   THE CHARACTERIZATION OF X-RAY PHOTO-CATHODES IN THE 0.1-10-KEV PHOTON ENERGY REGION [J].
HENKE, BL ;
KNAUER, JP ;
PREMARATNE, K .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (03) :1509-1520
[9]   Efficient K-shell x-ray sources produced with titanium foils [J].
Hu, Guang-yue ;
Liu, Shen-ye ;
Zheng, Jian ;
Wu, Chang-shu ;
Li, Jing-hong ;
Wu, Shun-chao ;
Zhang, Ji-Yan ;
Yang, Jia-min ;
Yang, Guo-hong ;
Yi, Rong-qing ;
Du, Hua-bing ;
Huang, Yi-xiang ;
Hu, Xin ;
Ding, Yong-kun .
PHYSICS OF PLASMAS, 2007, 14 (03)
[10]   Characterization of a multi-keV x-ray source produced by nanosecond laser irradiation of a solid target: The influence of laser focus spot and target thickness [J].
Hu, Guang-Yue ;
Zheng, Jian ;
Shen, Bai-fei ;
Lei, An-le ;
Liu, Shen-Ye ;
Zhang, Ji-Yan ;
Yang, Jia-Min ;
Ding, Yong-Kun ;
Hu, Xin ;
Huang, Yi-Xiang ;
Du, Hua-Bing ;
Yi, Rong-Qing ;
Xu, Zhi-Zhan .
PHYSICS OF PLASMAS, 2008, 15 (02)