Low cost thermal transient anemometer for challenging gas flow rate measurements

被引:1
作者
Keniar, Khoudor [1 ]
Rattner, Alexander S. [2 ]
Garimella, Srinivas [1 ]
机构
[1] Georgia Inst Technol, GW Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Penn State Univ, Dept Mech Engn, University Pk, PA 16802 USA
关键词
Low cost sensor; Thermal transient anemometer; High turn down ratio; High pressure and corrosive environment; Low pressure drop; Internal flow;
D O I
10.1016/j.ijheatmasstransfer.2020.119865
中图分类号
O414.1 [热力学];
学科分类号
摘要
Few commercially available gas flow rate measurement devices can be employed in applications with strict pressure drop allowances, high working pressures, or corrosive working fluids. Additionally, most measurement approaches (e.g., turbine, rotameter, thermal dispersion) have limited turn-down ratios, generally less than 50. Here, a new economical and mechanically simple thermal transient anemometer design is proposed and evaluated for internal gas volumetric flow measurement. The flow meter operates through cyclical electrical heating and convective cooling of a thermocouple probe. Flow rates are correlated with average cooling-period temperatures. Heating and cooling profiles are dynamically adjusted during operation, permitting relatively good accuracy and a large turn-down ratio (450). The objective of this investigation is to model, design, and demonstrate the operation of the anemometer using air as working fluid. The anemometer has a measurement range of 0.5-226.5 l min(-1) with free stream temperatures varying between 22-26 degrees C. A segmented numerical model, which includes the varying heating loads and velocity profiles in the working fluid, is developed and validated. (C) 2020 Published by Elsevier Ltd.
引用
收藏
页数:9
相关论文
共 11 条
[1]  
[Anonymous], 2009, Ansys Inc, V15317, P1
[2]  
BAILEY JL, 1993, EXP FLUIDS, V15, P10, DOI 10.1007/BF00195590
[3]   A TRANSIENTLY HEATED NEEDLE ANEMOMETER [J].
BLAND, WL ;
NORMAN, JM ;
CAMPBELL, GS ;
CALISSENDORFF, C ;
MILLER, EE .
AGRICULTURAL AND FOREST METEOROLOGY, 1995, 74 (3-4) :227-235
[4]  
CHURCHILL SW, 1977, CHEM ENG-NEW YORK, V84, P91
[5]   Theoretical and experimental investigations of a wide-range thermal velocity sensor [J].
Durst, F ;
Al-Salaymeh, A ;
Jovanovic, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (03) :223-237
[6]   Ambient temperature and free stream turbulence effects on the thermal transient anemometer [J].
Foss, J. F. ;
Peabody, J. A. ;
Norconk, M. J. ;
Lawrenz, A. R. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (09) :2519-2526
[7]   The thermal transient anemometer [J].
Foss, JF ;
Schwannecke, JK ;
Lawrenz, AR ;
Mets, MW ;
Treat, SC ;
Dusel, MD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (11) :2248-2255
[8]  
Incropera FP., 2007, Fundamentals of heat and mass transfer, V6
[9]  
Nellis G, 2009, HEAT TRANSFER-BOOK, P1
[10]  
Pope S.B., 2000, Meas. Sci. Technol.