A high-performance polycarbonate electrophoresis microchip with integrated three-electrode system for end-channel amperometric detection

被引:42
|
作者
Wang, Yurong [1 ]
Chen, Hengwu [1 ]
He, Qiaohong [1 ]
Soper, Steven A. [2 ,3 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Micro Analyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
amperometric detection; electroless plating; microfluidic chip; polycarbonate;
D O I
10.1002/elps.200700377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully integrated polycarbonate (PC) microchip for CE with end-channel electrochemical detection operated in an amperometric mode (CE-ED) has been developed. The on-chip integrated three-electrode system consisted of a gold working electrode, an Ag/AgCl reference electrode and a platinum counter electrode, which was fabricated by photo-directed electroless plating combined with electroplating. The working electrode was positioned against the separation channel exit to reduce post-channel band broadening. The electrophoresis high-voltage (HV) interference with the amperometric detection was assessed with respect to detection noise and potential shifts at various working-to-reference electrode spacing. It was observed that the electrophoresis HV interference caused by positioning the working electrode against the channel exit could be diminished by using an on-chip integrated reference electrode that was positioned in close proximity (100 pm) to the working electrode. The CE-ED microchip was demonstrated for the separation of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 132 and 164 nM were achieved for DA and CA, respectively, and a theoretical plate number of 2.5 x 10(4)/m was obtained for DA. Relative standard deviations in peak heights observed for five runs of a standard solution containing the two analytes (0.1 mM for each) were 1.2 and 3.1% for DA and CA, respectively. The chip could be continuously used for more than 8 h without significant deterioration in analytical performance.
引用
收藏
页码:1881 / 1888
页数:8
相关论文
共 50 条
  • [41] High-performance amperometric detection of hydroxylamine on fluorine doped tin oxide electrode modified with NiCo2O4 nanoparticles
    Ramesh, Asha
    Gudipati, Neeraja Sinha
    Vanjari, Siva Rama Krishna
    Subrahmanyam, Ch.
    ELECTROCHIMICA ACTA, 2023, 461
  • [42] ANALYSIS OF DIPEPTIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITHOUT DERIVATIZATION USING AMPEROMETRIC DETECTION ON A COPPER ELECTRODE
    STULIK, K
    PACAKOVA, V
    JOKUSZIES, G
    JOURNAL OF CHROMATOGRAPHY, 1988, 436 (02): : 334 - 337
  • [43] DIFFERENTIAL PULSE AMPEROMETRIC DETECTION OF DRUGS IN PLASMA USING A DROPPING MERCURY-ELECTRODE AS A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTOR
    HACKMAN, MR
    BROOKS, MA
    JOURNAL OF CHROMATOGRAPHY, 1981, 222 (02): : 179 - 190
  • [44] Determination of furanic aldehydes in sugarcane bagasse by high-performance liquid chromatography with pulsed amperometric detection using a modified electrode with nickel nanoparticles
    da Silva, Jose Luiz
    Beluomini, Maisa Azevedo
    Stradiotto, Nelson Ramos
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (18) : 3176 - 3182
  • [45] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF REPROTEROL IN PLASMA USING ONLINE TRACE ENRICHMENT AND AMPEROMETRIC DETECTION WITH A ROTATING WORKING ELECTRODE
    HAGEMAN, RJJ
    GREVING, JE
    JONKMAN, JHG
    DEZEEUW, RA
    JOURNAL OF CHROMATOGRAPHY, 1983, 274 (MAY): : 239 - 253
  • [46] EXPERT SYSTEM FOR PHARMACEUTICAL ANALYSIS .1. SELECTION OF THE DETECTION SYSTEM IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS - UV VERSUS AMPEROMETRIC DETECTION
    MUSCH, G
    DESMET, M
    MASSART, DL
    JOURNAL OF CHROMATOGRAPHY, 1985, 348 (01): : 97 - 110
  • [47] HIGH-PERFORMANCE LC BIELECTRODE AMPEROMETRIC FLOW-THROUGH DETECTOR WITH A CARBON-DROPPING MERCURY SENSOR-ELECTRODE SYSTEM
    KUTNER, W
    KEMULA, W
    CHROMATOGRAPHIA, 1983, 17 (06) : 322 - 327
  • [48] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SULFUR-CONTAINING AMINO-ACIDS AND RELATED-COMPOUNDS WITH AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE
    COX, JA
    DABEKZLOTORZYNSKA, E
    JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01): : 226 - 232
  • [49] Comparisons of disposable and conventional silver working electrode for the determination of iodide using high-performance anion-exchange chromatography with pulsed amperometric detection
    Liang, LN
    Cai, YQ
    Mou, SF
    Cheng, J
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) : 37 - 41
  • [50] 264-channel high-performance magnetic field detection system for transcranial magnetic stimulation (TMS)
    Xiong, Hui
    Chen, Kunhan
    Liu, Jinzhen
    Qi, Hailong
    Tian, Kaiwen
    MEASUREMENT, 2020, 164