A high-performance polycarbonate electrophoresis microchip with integrated three-electrode system for end-channel amperometric detection

被引:42
|
作者
Wang, Yurong [1 ]
Chen, Hengwu [1 ]
He, Qiaohong [1 ]
Soper, Steven A. [2 ,3 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Micro Analyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
amperometric detection; electroless plating; microfluidic chip; polycarbonate;
D O I
10.1002/elps.200700377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully integrated polycarbonate (PC) microchip for CE with end-channel electrochemical detection operated in an amperometric mode (CE-ED) has been developed. The on-chip integrated three-electrode system consisted of a gold working electrode, an Ag/AgCl reference electrode and a platinum counter electrode, which was fabricated by photo-directed electroless plating combined with electroplating. The working electrode was positioned against the separation channel exit to reduce post-channel band broadening. The electrophoresis high-voltage (HV) interference with the amperometric detection was assessed with respect to detection noise and potential shifts at various working-to-reference electrode spacing. It was observed that the electrophoresis HV interference caused by positioning the working electrode against the channel exit could be diminished by using an on-chip integrated reference electrode that was positioned in close proximity (100 pm) to the working electrode. The CE-ED microchip was demonstrated for the separation of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 132 and 164 nM were achieved for DA and CA, respectively, and a theoretical plate number of 2.5 x 10(4)/m was obtained for DA. Relative standard deviations in peak heights observed for five runs of a standard solution containing the two analytes (0.1 mM for each) were 1.2 and 3.1% for DA and CA, respectively. The chip could be continuously used for more than 8 h without significant deterioration in analytical performance.
引用
收藏
页码:1881 / 1888
页数:8
相关论文
共 50 条
  • [1] A high performance polycarbonate CE microchip with integrated three electrode system for end-channel amperometric detection
    Wang, Yu-Rong
    Chen, Heng-Wu
    He, Qiao-Hong
    Soper, Steven A.
    PROCEEDINGS OF THE FIRST SHENYANG INTERNATIONAL COLLOQUIUM ON MICROFLUIDICS, 2007, : 173 - 176
  • [2] An end-channel amperometric detector for microchip capillary electrophoresis
    Wu, YY
    Lin, JM
    Su, RG
    Qu, F
    Cai, ZW
    TALANTA, 2004, 64 (02) : 338 - 344
  • [3] Electrophoresis microchip fabricated by a direct-printing process with end-channel amperometric detection
    Coltro, WKT
    da Silva, JAF
    da Silva, HDT
    Richter, EM
    Furlan, R
    Angnes, L
    do Lago, CL
    Mazo, LH
    Carrilho, E
    ELECTROPHORESIS, 2004, 25 (21-22) : 3832 - 3839
  • [4] Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection
    Wu, CC
    Wu, RG
    Huang, JG
    Lin, YC
    Chang, HC
    ANALYTICAL CHEMISTRY, 2003, 75 (04) : 947 - 952
  • [5] Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Teng, Wei
    Hahn, Jong Hoon
    ELECTROPHORESIS, 2011, 32 (08) : 838 - 843
  • [6] Microchip capillary electrophoresis with an end-channel amperometric detector and its preliminary application
    Wu, YY
    Qu, F
    Lin, JM
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (02) : 155 - 159
  • [7] Development of a microfabricated disposable microchip with a capillary electrophoresis and integrated three-electrode electrochemical detection
    Kim, JH
    Kang, CJ
    Kim, YS
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (11): : 2314 - 2317
  • [8] Determination of phenol in landfill leachate by using microchip capillary electeophoresis with end-channel amperometric detection
    Wu, YY
    Lin, JM
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) : 137 - 143
  • [9] A new fabrication process for a microchip electrophoresis device integrated with a three-electrode electrochemical detector
    Tsai, DM
    Lin, KW
    Zen, JM
    Chen, HY
    Hong, RH
    ELECTROPHORESIS, 2005, 26 (15) : 3007 - 3012
  • [10] Amperometric detection in microchip electrophoresis devices: Effect of electrode material and alignment on analytical performance
    Fischer, David J.
    Hulvey, Matthew K.
    Regel, Anne R.
    Lunte, Susan M.
    ELECTROPHORESIS, 2009, 30 (19) : 3324 - 3333