Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy

被引:6
|
作者
Kim, Rihyeon [1 ]
Park, Eun-Ah [1 ]
Lee, Whal [1 ]
Chung, Jin Wook [1 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
关键词
Computed tomography coronary angiography; Contrast material; Contrast-induced nephropathy; 320-row area detector CT; Diagnostic accuracy; BODY-MASS INDEX; COMPUTED-TOMOGRAPHY; INDUCED NEPHROPATHY; ENHANCEMENT; ATTENUATION; INJECTION; MEDIA; NEPHROTOXICITY; INTERVENTION; REDUCTION;
D O I
10.1007/s00330-016-4275-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation > 250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. aEuro cent 320-ADCT might enable reduction of contrast material volume. aEuro cent A 40-mL contrast protocol for 320-ADCT provided acceptable image quality. aEuro cent A 40-mL contrast protocol for 320-ADCT demonstrated sufficient diagnostic accuracy.
引用
收藏
页码:3802 / 3810
页数:9
相关论文
共 50 条
  • [41] CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy
    Dewey, Marc
    Teige, Florian
    Rutsch, Wolfgang
    Schink, Tania
    Hamm, Bernd
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) : 92 - 99
  • [42] 320-detector CT coronary angiography with prospective and retrospective electrocardiogram gating in a single heartbeat: comparison of image quality and radiation dose
    Qin, J.
    Liu, L-Y
    Fang, Y.
    Zhu, J-M
    Wu, Z.
    Zhu, K-S
    Zhang, J-S
    Shan, H.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015) : 945 - 951
  • [43] Iterative Reconstruction to Preserve Image Quality and Diagnostic Accuracy at Reduced Radiation Dose in Coronary CT Angiography An Intraindividual Comparison
    Yin, Wei-Hua
    Lu, Bin
    Li, Nan
    Han, Lei
    Hou, Zhi-Hui
    Wu, Run-Ze
    Wu, Yong-Jian
    Niu, Hong-Xia
    Jiang, Shi-Liang
    Krazinski, Aleksander W.
    Ebersberger, Ullrich
    Meinel, Felix G.
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (12) : 1239 - 1249
  • [44] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01) : 139 - 146
  • [45] Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT
    Patrick A. Hein
    Juliane May
    Patrik Rogalla
    Craig Butler
    Bernd Hamm
    Alexander Lembcke
    European Radiology, 2010, 20 : 1337 - 1343
  • [46] Diagnostic Accuracy, Image Quality and Patient Comfort for Coronary CT Angiography Performed Using Iso-Osmolar versus Low-Osmolar Iodinated Contrast: A Prospective International Multicenter Randomized Controlled Trial
    Nakazato, Ryo
    Arsanjani, Reza
    Shalev, Aryeh
    Leipsic, Jonathon A.
    Gransar, Heidi
    Lin, Fay Y.
    Gomez, Millie
    Berman, Daniel S.
    Min, James K.
    ACADEMIC RADIOLOGY, 2016, 23 (06) : 743 - 751
  • [47] Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
    Kim, Eun Young
    Yeh, Dae Wook
    Choe, Yeon Hyeon
    Lee, Won Jae
    Lim, Hyo Keun
    ACTA RADIOLOGICA, 2010, 51 (09) : 982 - 989
  • [48] Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Schlattmann, Peter
    Knebel, Fabian
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2009, 120 (10) : 867 - 875
  • [49] Evaluation Of Coronary Artery Lesion In 9 Infantile Kawasaki Disease Patients Using 320row Area Detector Ct
    Tsuzuki, Yoshimitsu
    Mizuno, Masanori
    Yousuke, Osada
    Nakano, Marie
    Sakurai, Kenzo
    Masumori, Chikako
    Arima, Masaki
    Gotou, Kenzirou
    Aso, Kentarou
    CIRCULATION, 2015, 131
  • [50] Evaluation Of Coronary Artery Lesion In 9 Infantile Kawasaki Disease Patients Using 320row Area Detector Ct
    Tsuzuki, Yoshimitsu
    Mizuno, Masanori
    Yousuke, Osada
    Nakano, Marie
    Sakurai, Kenzo
    Masumori, Chikako
    Arima, Masaki
    Gotou, Kenzirou
    Aso, Kentarou
    CIRCULATION, 2015, 131