To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation > 250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. aEuro cent 320-ADCT might enable reduction of contrast material volume. aEuro cent A 40-mL contrast protocol for 320-ADCT provided acceptable image quality. aEuro cent A 40-mL contrast protocol for 320-ADCT demonstrated sufficient diagnostic accuracy.
引用
收藏
页码:3802 / 3810
页数:9
相关论文
共 50 条
  • [1] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Rihyeon Kim
    Eun-Ah Park
    Whal Lee
    Jin Wook Chung
    European Radiology, 2016, 26 : 3802 - 3810
  • [2] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1059 - 1068
  • [3] Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method
    Oda, Seitaro
    Utsunomiya, Daisuke
    Yuki, Hideaki
    Kai, Noriyuki
    Hatemura, Masahiro
    Funama, Yoshinori
    Kidoh, Masafumi
    Yoshida, Morikatsu
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (01) : 19 - 27
  • [4] The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT
    Tomizawa, Nobuo
    Yamamoto, Kodai
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04) : 907 - 911
  • [5] Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography
    Fuchs, Andreas
    Kuhl, J. Tobias
    Chen, Marcus Y.
    Helquist, Steffen
    Razeto, Marco
    Arakita, Kazumasa
    Steveson, Chloe
    Arai, Andrew E.
    Kofoed, Klaus F.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) : 393 - 398
  • [6] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [7] Effective temporal resolution and image quality of volume scanning in 320-row detector CT
    Urikura, Atsushi
    Hara, Takanori
    Yoshida, Tsukasa
    Nishimaru, Eiji
    Hoshino, Takashi
    Ichikawa, Katsuhiro
    Nakaya, Yoshihiro
    Endo, Masahiro
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) : 503 - 510
  • [8] Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography
    Tomizawa, Nobuo
    Suzuki, Fumio
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1255 - 1259
  • [9] Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium
    Chimura, Misato
    Ohtani, Tomohito
    Yokoi, Kensuke
    Shiraki, Tatsuya
    Katsimichas, Themistoklis
    Kitao, Takashi
    Awata, Masaki
    Mizote, Isamu
    Hikoso, Shungo
    Sumitsuji, Satoru
    Sakata, Yasushi
    HEART AND VESSELS, 2020, 35 (10) : 1341 - 1348
  • [10] Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT
    Zhang, WeiGuo
    Jin, Hang
    Chen, Gang
    Chen, Wenfang
    Gu, Junying
    Zeng, Mengsu
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1628 - 1635