Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
被引:6
|
作者:
Kim, Rihyeon
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South KoreaSeoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
Kim, Rihyeon
[1
]
Park, Eun-Ah
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South KoreaSeoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
Park, Eun-Ah
[1
]
Lee, Whal
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South KoreaSeoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
Lee, Whal
[1
]
Chung, Jin Wook
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South KoreaSeoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
Chung, Jin Wook
[1
]
机构:
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation > 250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. aEuro cent 320-ADCT might enable reduction of contrast material volume. aEuro cent A 40-mL contrast protocol for 320-ADCT provided acceptable image quality. aEuro cent A 40-mL contrast protocol for 320-ADCT demonstrated sufficient diagnostic accuracy.
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
Zhang, Chuanchen
Zhang, Zhaoqi
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
Zhang, Zhaoqi
Yan, Zixu
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
Yan, Zixu
Xu, Lei
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
Xu, Lei
Yu, Wei
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
Yu, Wei
Wang, Rui
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R ChinaCapital Med Univ, Dept Radiol, Beijing Anzhen Hosp, Beijing 100029, Peoples R China
机构:
Kumamoto Univ Hosp, Dept Cent Radiol, Kumamoto, JapanKumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, Kumamoto 8608556, Japan
Kai, Noriyuki
Hatemura, Masahiro
论文数: 0引用数: 0
h-index: 0
机构:
Kumamoto Univ Hosp, Dept Cent Radiol, Kumamoto, JapanKumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, Kumamoto 8608556, Japan
Hatemura, Masahiro
Funama, Yoshinori
论文数: 0引用数: 0
h-index: 0
机构:
Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, JapanKumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, Kumamoto 8608556, Japan
Funama, Yoshinori
论文数: 引用数:
h-index:
机构:
Kidoh, Masafumi
论文数: 引用数:
h-index:
机构:
Yoshida, Morikatsu
论文数: 引用数:
h-index:
机构:
Namimoto, Tomohiro
Yamashita, Yasuyuki
论文数: 0引用数: 0
h-index: 0
机构:
Kumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, Kumamoto 8608556, JapanKumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, Kumamoto 8608556, Japan
机构:
Shizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Urikura, Atsushi
Hara, Takanori
论文数: 0引用数: 0
h-index: 0
机构:
Nakatsugawa Municipal Gen Hosp, Dept Med Technol, 1522-1 Komanba, Gifu 5080011, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Hara, Takanori
Yoshida, Tsukasa
论文数: 0引用数: 0
h-index: 0
机构:
Shizuoka Canc Ctr, Div Radiat & Proton Therapy Ctr, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Yoshida, Tsukasa
Nishimaru, Eiji
论文数: 0引用数: 0
h-index: 0
机构:
Hiroshima Univ Hosp, Dept Radiol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Nishimaru, Eiji
Hoshino, Takashi
论文数: 0引用数: 0
h-index: 0
机构:
Osaka Coll High Technol, Dept Radiol Technol, Yodogawa Ku, 1-2-8 Miyahara, Osaka, Osaka 5320003, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Hoshino, Takashi
Ichikawa, Katsuhiro
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ Grad Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Ichikawa, Katsuhiro
Nakaya, Yoshihiro
论文数: 0引用数: 0
h-index: 0
机构:
Shizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
Nakaya, Yoshihiro
Endo, Masahiro
论文数: 0引用数: 0
h-index: 0
机构:
Shizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, JapanShizuoka Canc Ctr, Div Diagnost Radiol, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan