Insertion force in manual and robotic corneal suturing

被引:13
作者
Yang, Yang [1 ]
Xu, Cunliang [1 ]
Deng, Shijing [2 ]
Xiao, Jingjing [1 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Dept Mech Design, Beijing 100191, Peoples R China
[2] Beijing Inst Ophthalmol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
corneal suturing; insertion force; micro-forceps manipulator; insertion trajectory; SURGERY;
D O I
10.1002/rcs.419
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. Methods In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. Results The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M-dmax (the maximum of square root of the quadratic sum of torque components M-OX and M-OY) in robotic suturing is much smaller than that in manual suturing. Conclusions The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 20 条
  • [1] Robotic microsurgery: corneal transplantation
    Bourges, J-L
    Hubschman, J-P
    Burt, B.
    Culjat, M.
    Schwartz, S. D.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (12) : 1672 - 1675
  • [2] Furusho J, 2008, P IEEE INT C MECH AU, P290
  • [3] HARWELL R C, 1983, Microsurgery, V4, P187, DOI 10.1002/micr.1920040310
  • [4] Position control of needle tip with force feedback and liver model
    Kobayashi, Y
    Okamoto, J
    Fujie, MG
    [J]. CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 719 - 724
  • [5] LeDuc M, 2003, PROC GRAPH INTERF, P273
  • [6] Development and application of a new steady-hand manipulator for retinal surgery
    Mitchell, Ben
    Koo, John
    Lordachita, Lulian
    Kazanzides, Peter
    Kapoor, Ankur
    Handa, James
    Hager, Gregory
    Taylor, Russell
    [J]. PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 623 - 629
  • [7] Mitsuishi M, 1998, LECT NOTES CONTR INF, V232, P457
  • [8] Murry R. M., 1994, MATH INTRO ROBOTIC M
  • [9] Nageotte F, 2005, IEEE INT CONF ROBOT, P514
  • [10] A parallel robot to assist vitreoretinal surgery
    Nakano, Taiga
    Sugita, Naohiko
    Ueta, Takashi
    Tamaki, Yasuhiro
    Mitsuishi, Mamoru
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (06) : 517 - 526