Uni and bi-directional dewatering behaviour of open geotextile containers used for filtration of waste slurries

被引:2
作者
e Silva, Rodrigo A. [1 ]
Vidal, Delma [2 ]
机构
[1] Queens Univ, GeoEngn Ctr Queens RMC, Dept Civil Engn, Kingston, ON, Canada
[2] Aeronaut Inst Technol, Dept Civil Engn, Sao Jose Dos Campos, SP, Brazil
关键词
Geotextiles; Slurries; Multidirectional flow; Filtration mechanisms; Filter cake; Probabilistic model; Retention prediction; TUBES; PERFORMANCE; TAILINGS; SLUDGE; BAGS;
D O I
10.1016/j.geotexmem.2021.12.004
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The simultaneous analysis of filtration mechanisms under vertical, horizontal, and bi-directional flow conditions has not yet been clarified for geotextile-dewatering involving different grain-sized slurries, therefore it is still not obvious which condition is dominant as particle sizes vary. In this paper, the differences associated to horizontal versus vertical filtration are investigated based on solids retention and effluent volume through the geotextiles. Three geotextile materials (two woven and a nonwoven) are separately employed for the filtration of three slurries with d50 ranging from 55 im to 410 im using an open dewatering unit. To facilitate the formation of a permeable filter cake on the inside of the geotextile surface, a range of particles with grain size distribution indicating internal stability was chosen for the slurries. The geotextile/slurry combinations targeted possible unfavorable retention conditions wherein only the particles of approximately the same size as the largest opening size of the filter could be retained (O90/d85 >= 1.0). A probabilistic model based on the geotextile pore size distribution curve and number of constrictions is added to the laboratory investigation to assess the geotextile retention reliability and confirms that for most cases slurry particles of all sizes can pass through the filters. Nonetheless, filtration efficiencies greater than 90% and control of particle loss are reached relatively fast for almost all experiments. In other words, it is a range of particles retained at the beginning of filtration tests that stimulates filter cake formation and governs further retention.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 51 条
[1]   Effect of different sediment dewatering techniques on subsequent particle sizes in industrial derived effluent [J].
Alimohammadi, M. ;
Tackley, H. A. ;
Lake, C. B. ;
Spooner, I ;
Walker, T. R. ;
Jamieson, R. ;
Gan, C. ;
Bossy, K. .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 2020, 47 (10) :1145-1153
[2]   Beach restoration with geotextile tubes as submerged breakwaters in Yucatan, Mexico [J].
Alvarez, Ing E. ;
Rubio, Ramiro ;
Ricalde, Herbert .
GEOTEXTILES AND GEOMEMBRANES, 2007, 25 (4-5) :233-241
[3]  
[Anonymous], 2010, 11058 ISO
[4]  
[Anonymous], 2016, ISO 9863-1
[5]  
[Anonymous], 2013, D7880 ASTM
[6]  
[Anonymous], 2010, 12956 ISO
[7]  
[Anonymous], 2016, D4751 ASTM
[8]  
[Anonymous], 2016, D6767 ASTM
[9]  
[Anonymous], 2013, 9864 ISO
[10]  
API, 1985, STAND TEST PROC FIEL