The effect of drilling angle on posterior interosseous nerve safety during open and endoscopic anterior single-incision repair of the distal biceps tendon

被引:34
作者
Saldua, Nelson [1 ]
Carney, Joseph [1 ]
Dewing, Christopher [1 ]
Thompson, Michael [1 ]
机构
[1] Naval Med Ctr, Dept Orthopaed, San Diego, CA USA
关键词
distal biceps tendon rupture; posterior interosseous nerve; EndoButton repair;
D O I
10.1016/j.arthro.2007.09.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to define a safe trajectory with regard to iatrogenic posterior interosseous nerve (PIN) injury when drilling the bicipital tuberosity for EndoButton repair (Smith & Nephew Endoscopy, Andover, MA) of distal biceps tendon ruptures. Methods: Ten cadaveric forearms were dissected. The bicipital tuberosity was exposed and the biceps tendon detached. The supinator and PIN were exposed dorsally. A K-wire was drilled perpendicular to the surface of the tuberosity. By use of digital calipers, the distance from the exit point of this wire to the PIN was measured. The length of the bone tunnel was also measured. This wire was removed, and a second was drilled from the same starting point but directed 30 degrees ulnarly. Measurements were repeated. A Wilcoxon signed rank test was used to compare the distances of the K-wire to the PIN and the tunnel lengths for both trajectories. Results: With the perpendicular wire, the mean distance to the PIN was 11.1 mm. When directed 30 degrees ulnarly, the mean distance was 16.4 mm. The difference was significant (P < .001). The mean bone tunnel lengths for the 2 trajectories were 17.8 mm and 18.1 mm; this was not found to be significant (P = .508). Conclusions: When drilling the bicipital tuberosity, we advocate starting at a center-center position on the face of the tuberosity, holding the forearm in maximum supination, and aiming 30 degrees ulnarly to decrease the risk to the PIN. This trajectory does not decrease the bone tunnel length available for implants. Clinical Relevance: This cadaveric anatomic study establishes safety from iatrogenic PIN injury during drilling of the bicipital tuberosity for the purpose of open or endoscopic EndoButton repair of distal biceps tendon ruptures.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 21 条
[11]   RUPTURE OF DISTAL BICEPS TENDON - REPORT OF 5 CASES [J].
HOVELIUS, L ;
JOSEFSSON, G .
ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (03) :280-282
[12]   AVULSION OF THE DISTAL BICEPS BRACHII TENDON [J].
KRON, SD ;
SATINSKY, VP .
AMERICAN JOURNAL OF SURGERY, 1954, 88 (04) :657-659
[13]   Distal rupture of the tendon of biceps brachii - Evaluation by MRI and the results of repair [J].
LeHuec, JC ;
Moinard, M ;
Liquois, F ;
Zipoli, B ;
Chauveaux, D ;
LeRebeller, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :767-770
[14]  
LEIGHTON MM, 1995, CLIN ORTHOP RELAT R, P114
[15]  
Lintner S, 1996, CLIN ORTHOP RELAT R, P116
[16]  
Mazurek MT, 2001, CLIN ORTHOP RELAT R, P7
[17]   THE TREATMENT OF RUPTURES OF THE DISTAL BICEPS BRACHII TENDON [J].
MEHERIN, JM ;
KILGORE, ES .
AMERICAN JOURNAL OF SURGERY, 1960, 99 (05) :636-640
[18]   RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - A BIOMECHANICAL STUDY [J].
MORREY, BF ;
ASKEW, LJ ;
AN, KN ;
DOBYNS, JH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03) :418-421
[19]   TENDON-HEALING IN A BONE TUNNEL - A BIOMECHANICAL AND HISTOLOGICAL STUDY IN THE DOG [J].
RODEO, SA ;
ARNOCZKY, SP ;
TORZILLI, PA ;
HIDAKA, C ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (12) :1795-1803
[20]   Endoscopic repair of distal biceps tendon using an EndoButton [J].
Sharma, S ;
MacKay, G .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (07) :897.e1-897.e4