Comparison of the performance of the IDEXX SediVue Dx® with manual microscopy for the detection of cells and 2 crystal types in canine and feline urine

被引:16
作者
Hernandez, Annalisa M. [1 ]
Bilbrough, Graham E. A. [2 ]
DeNicola, Dennis B. [2 ]
Myrick, Celine [2 ]
Edwards, Suzanne [2 ]
Hammond, Jeremy M. [2 ]
Myers, Alex N. [1 ]
Heseltine, Johanna C. [3 ]
Russell, Karen [1 ]
Giraldi, Marco [4 ]
Nabity, Mary B. [1 ]
机构
[1] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Vet Pathobiol, 4467 TAMU, College Stn, TX 77843 USA
[2] IDEXX Labs Inc, Westbrook, ME USA
[3] Texas A&M Univ, Coll Vet Med & Biomed Sci, Small Anim Clin Sci, College Stn, TX 77843 USA
[4] Univ Milan, Dept Vet Med, Milan, Italy
来源
JOURNAL OF VETERINARY INTERNAL MEDICINE | 2019年 / 33卷 / 01期
关键词
automated analyzer; cat; dog; urinalysis; urine formed elements; urine sediment; FLOW CYTOMETER; AUTOMATED MICROSCOPY; SEDIMENT EXAMINATION; TEST STRIPS; URINALYSIS; ANALYZERS;
D O I
10.1111/jvim.15341
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Microscopic evaluation of urine is inconsistently performed in veterinary clinics. The IDEXX SediVue Dx (R) Urine Sediment Analyzer (SediVue) recently was introduced for automated analysis of canine and feline urine and may facilitate performance of urinalyses in practice. Objective Compare the performance of the SediVue with manual microscopy for detecting clinically relevant numbers of cells and 2 crystal types. Samples Five-hundred thirty urine samples (82% canine, 18% feline). Methods For SediVue analysis (software versions [SW] 1.0.0.0 and 1.0.1.3), uncentrifuged urine was pipetted into a cartridge. Images were captured and processed using a convolutional neural network algorithm. For manual microscopy, urine was centrifuged to obtain sediment. To determine sensitivity and specificity of the SediVue compared with manual microscopy, thresholds were set at >= 5/high power field (hpf) for red blood cells (RBC) and white blood cells (WBC) and >= 1/hpf for squamous epithelial cells (sqEPI), non-squamous epithelial cells (nsEPI), struvite crystals (STR), and calcium oxalate dihydrate crystals (CaOx Di). Results The sensitivity of the SediVue (SW1.0.1.3) was 85%-90% for the detection of RBC, WBC, and STR; 75% for CaOx Di; 71% for nsEPI; and 33% for sqEPI. Specificity was 99% for sqEPI and CaOx Di; 87%-90% for RBC, WBC, and nsEPI; and 84% for STR. Compared to SW1.0.0.0, SW1.0.1.3 had increased sensitivity but decreased specificity. Performance was similar for canine versus feline and fresh versus stored urine samples. Conclusions and Clinical Importance The SediVue exhibits good agreement with manual microscopy for the detection of most formed elements evaluated, but improvement is needed for epithelial cells.
引用
收藏
页码:167 / 177
页数:11
相关论文
共 19 条
  • [1] Comparison of LabUMat-with-UriSed and iQ®200 fully automatic urine sediment analysers with manual urine analysis
    Akin, Okhan Kadir
    Serdar, Muhittin A.
    Cizmeci, Zeynep
    Genc, Ozlem
    Aydin, Suleyman
    [J]. BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2009, 53 : 139 - 144
  • [2] Preliminary evaluation of the IRIS IQ™ 200 automated urine analyser
    Alves, L
    Ballester, F
    Camps, J
    Joven, J
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (09) : 967 - 970
  • [3] Evaluation of a new automated microscopy urine sediment analyser - sediMAX conTRUST®
    Bogaert, Laura
    Peeters, Bart
    Billen, Jaak
    [J]. ACTA CLINICA BELGICA, 2017, 72 (02) : 91 - 94
  • [4] Urinalysis: Comparison between Microscopic Analysis and a New Automated Microscopy Image-Based Urine Sediment Instrument
    Bottini, Paula V.
    Martinez, Mayara H. M.
    Garlipp, Celia R.
    [J]. CLINICAL LABORATORY, 2014, 60 (04) : 693 - 697
  • [5] AUTOMATED URINALYSIS
    CARLSON, DA
    STATLAND, BE
    [J]. CLINICS IN LABORATORY MEDICINE, 1988, 8 (03) : 449 - 461
  • [6] Urine sediment examination: A comparison of automated urinalysis systems and manual microscopy
    Chien, Tzu-I
    Kao, Jau-Tsuen
    Liu, Hui-Lan
    Lin, Po-Chang
    Hong, Jhih-Sian
    Hsieh, Han-Peng
    Chien, Miao-Ju
    [J]. CLINICA CHIMICA ACTA, 2007, 384 (1-2) : 28 - 34
  • [7] The automation of sediment urinalysis using a new urine flow cytometer (UF-100™)
    Fenili, D
    Pirovano, B
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) : 909 - 917
  • [8] Automation of urine sediment examination: A comparison of the sysmex UF-100 automated flow cytometer with routine manual diagnosis (microscopy, test strips, and bacterial culture)
    Hannemann-Pohl, K
    Kampf, SC
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1999, 37 (07) : 753 - 764
  • [9] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [10] Analytical performance of the Iris iQ200 automated urine microscopy analyzer
    Linko, Solveig
    Kouri, Timo T.
    Toivonen, Ella
    Ranta, Paivi H.
    Chapoulaud, Eric
    Lalla, Martti
    [J]. CLINICA CHIMICA ACTA, 2006, 372 (1-2) : 54 - 64