Reliability improvement of high frequency electronic ballasts for metal halide lamps
被引:0
作者:
Cao, XH
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Inst Power Elect, Hangzhou 310027, Peoples R ChinaZhejiang Univ, Inst Power Elect, Hangzhou 310027, Peoples R China
Cao, XH
[1
]
Hui, SYR
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Inst Power Elect, Hangzhou 310027, Peoples R ChinaZhejiang Univ, Inst Power Elect, Hangzhou 310027, Peoples R China
Hui, SYR
[1
]
机构:
[1] Zhejiang Univ, Inst Power Elect, Hangzhou 310027, Peoples R China
来源:
APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3
|
2004年
关键词:
ballast;
MH lamp;
zero voltage switching;
reliability;
D O I:
暂无
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
An auxiliary resonant tank-protected high-frequency electronic ballast is proposed in this paper. Based on the steady state analysis of the series resonant converter, the operational characteristics of the ballast circuit for metal halide (MH) lamps under different conditions are examined, and then potential hazards to the ballast circuit are addressed. To avoid those dangers, an auxiliary resonant tank is used for protecting the ballast circuit under all operations. With this auxiliary resonant tank, the reliability of the ballast can be improved significantly. Feasibility of the proposal for the ballast circuit is verified by analytical and experimental results obtained from the 150W prototype ballast.