Biomechanical Comparison of Fixation With a Single Screw Versus Two Kirschner Wires in Distal Chevron Osteotomies of the First Metatarsal: A Cadaver Study

被引:17
作者
Trost, Matthias [1 ]
Bredow, Jan [2 ]
Boese, Christoph Kolja [3 ]
Loweg, Lennard
Schulte, Tobias Ludger [1 ]
Scaal, Martin [4 ]
Eysel, Peer [5 ,6 ]
Oppermann, Johannes [6 ]
机构
[1] Univ Bochum, St Josef Hosp, Dept Orthopaed & Traumatol, Gudrunstr 56, D-44791 Bochum, Germany
[2] Schon Klin, Dept Spinal Surg, Dusseldorf, Germany
[3] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[4] Univ Cologne, Inst Anat 2, Cologne, Germany
[5] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[6] Univ Cologne, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
关键词
cantilever; foot; hallux valgus; load; osteosynthesis; RANDOMIZED CONTROLLED-TRIAL; SEVERE HALLUX-VALGUS; SOFT-TISSUE RELEASE; SHAFT OSTEOTOMIES; ANKLE ARTHRODESIS; STABILITY;
D O I
10.1053/j.jfas.2017.08.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% +/- 27% in group 1 and 68% +/- 18% in group 2 (p = .50). In the physiologic configuration, it was 38% +/- 25% in group 1 and 35% +/- 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 +/- 105 N in group 1 and 259 +/- 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus. (C) 2017 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 25 条
  • [1] Mechanical comparison of cyclic loading in five different first metatarsal shaft osteotomies
    Acevedo, JI
    Sammarco, VJ
    Boucher, HR
    Parks, BG
    Schon, LC
    Myerson, MS
    [J]. FOOT & ANKLE INTERNATIONAL, 2002, 23 (08) : 711 - 716
  • [2] Armstrong D G, 1997, J Foot Ankle Surg, V36, P353
  • [3] AUSTIN DW, 1981, CLIN ORTHOP RELAT R, P25
  • [4] Buckenberger R K, 1995, J Foot Ankle Surg, V34, P266
  • [5] Fixation comparison for chevron osteotomies
    Crosby, LA
    Bozarth, GR
    [J]. FOOT & ANKLE INTERNATIONAL, 1998, 19 (01) : 41 - 43
  • [6] Dalton Sandra K, 2003, J Foot Ankle Surg, V42, P53, DOI 10.1016/S1067-2516(03)70002-7
  • [7] Biomechanical consequences of first metatarsal osteotomy in treating hallux valgus
    Favre, P.
    Farine, M.
    Snedeker, J. G.
    Maquieira, G. J.
    Espinosa, N.
    [J]. CLINICAL BIOMECHANICS, 2010, 25 (07) : 721 - 727
  • [8] Stability of the offset V-osteotomy - Test jig development and saw bone model assessment
    Gonda, E
    Bauer, GR
    Hillstrom, HJ
    Song, JS
    Cho, HH
    Lundberg, LA
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2002, 92 (02) : 82 - 89
  • [9] Biomechanical comparison of screws and plates for hallux valgus opening-wedge and Ludloff osteotomies
    Hofstaetter, Stefan G.
    Glisson, Richard R.
    Alitz, Curtis J.
    Trnka, Hans J.
    Easley, Mark E.
    [J]. CLINICAL BIOMECHANICS, 2008, 23 (01) : 101 - 108
  • [10] The influence of patient age and bone mineral density on osteotomy fixation stability after hallux valgus surgery: A biomechanical study
    Hofstaetter, Stefan G.
    Riedl, Markus
    Glisson, Richard R.
    Trieb, Klemens
    Easley, Mark E.
    [J]. CLINICAL BIOMECHANICS, 2016, 32 : 255 - 260