Three-dimensional adaptive filtering in magnetic resonance angiography

被引:38
作者
Westin, CF [1 ]
Wigström, L [1 ]
Loock, T [1 ]
Sjöqvist, L [1 ]
Kikinis, R [1 ]
Knutsson, H [1 ]
机构
[1] Brigham & Womens Hosp, Surg Planning Lab, Boston, MA 02115 USA
关键词
angiography; adaptive filtering; noise reduction; tensor; image enhancement;
D O I
10.1002/jmri.1152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In order to enhance 3D image data from magnetic resonance angiography (MRA), a novel method based on the theory of multidimensional adaptive filtering has been developed. The purpose of the technique is to suppress Image noise while enhancing important structures. The method Is based on local structure estimation using six 3D orientation selective filters, followed by an adaptive filtering step controlled by the local structure information. The complete filtering procedure requires approximately 3 minutes of computational time on a standard workstation for a 256 x 256 x 64 data set. The method has been evaluated using a mathematical vessel model and in vivo MRA data (both phase contrast and time of flight (TOF)). 3D adaptive filtering results in a better delineation of small blood vessels and efficiently reduces the high-frequency noise. Depending on the data acquisition and the original data type, contrast-to-noise ratio (CNR) Improvements of up to 179% (8.9 dB) were observed. 3D adaptive filtering may provide an alternative to prolonging the scan time or using contrast agents in MRA when the CNR is low. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 35 条
[1]  
Alvarez L., 1993, ARCH RATION MECH AN, V123, P200
[2]  
[Anonymous], THESIS LINKOPING U S
[3]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[4]   A WEIGHTED LEAST-SQUARES METHOD FOR NUCLEAR-MAGNETIC-RESONANCE VELOCITY IMAGING [J].
CAPRIHAN, A ;
ICENOGLE, MV .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :512-520
[5]   AN ALGORITHM FOR MR-ANGIOGRAPHY IMAGE-ENHANCEMENT [J].
CHEN, HG ;
HALE, J .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :534-540
[6]   VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY [J].
CLINE, HE ;
DUMOULIN, CL ;
LORENSEN, WE ;
SOUZA, SP ;
ADAMS, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :384-394
[7]   VESSEL ENHANCEMENT FILTERING IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03) :353-359
[8]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[9]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[10]   SEARCH OF A GENERAL PICTURE PROCESSING OPERATOR [J].
GRANLUND, GH .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1978, 8 (02) :155-173